3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human Tibia

This paper presents a standard solid model for human tibia, accounting for the material characteristics of cortical bone, cancellous bone and bone marrow. A CT scan of a cadaveric human tibia was used as the basis of developed model. A total of 201 CT scan slices of the tibia were taken with the dis...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Almutairi, Mutlaq (author)
منشور في: 2019
الوصول للمادة أونلاين:https://dspace.auk.edu.kw/handle/11675/5747
https://scholarsjournal.net/index.php/ijier/article/view/1459
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1870679730454265857
author Almutairi, Mutlaq
author_facet Almutairi, Mutlaq
author_role author
dc.creator.none.fl_str_mv Almutairi, Mutlaq
dc.date.none.fl_str_mv 2019
2020-04-10T14:16:58Z
2020-04-10T14:16:58Z
dc.identifier.none.fl_str_mv https://dspace.auk.edu.kw/handle/11675/5747
https://scholarsjournal.net/index.php/ijier/article/view/1459
dc.publisher.none.fl_str_mv International Educative Research Foundation and Publisher (IERFP)
dc.relation.none.fl_str_mv International Journal for Innovation Education and Research (IJIER)
dc.title.none.fl_str_mv 3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human Tibia
dc.type.none.fl_str_mv Journal Article
Peer-Reviewed
info:eu-repo/semantics/publishedVersion
description This paper presents a standard solid model for human tibia, accounting for the material characteristics of cortical bone, cancellous bone and bone marrow. A CT scan of a cadaveric human tibia was used as the basis of developed model. A total of 201 CT scan slices of the tibia were taken with the distances between the scans varying along the length of the bone with a higher density at the proximal and distal ends, as those were the regions of interest. The data was imported into MIMICS (Materialise), and the threshold method was used to differentiate between the cortical bone region, cancellous bone region, and the bone marrow cavity. The solid model used to generate the FE model is constructed based on CT scan data of an actual cadaveric human tibia. The geometric information is retrieved and edited in (MIMICS). The surfaces defining the cortical bone, the proximal and distal epiphyseal cancellous bone and medullar cavity regions are converted into NURBS surfaces using (GEOMAGIC STUDIO).
id AUKR_0d7c20d7d09fc7a7ba61bc7f0a20c2bd
network_acronym_str AUKR
network_name_str AU Kuwait Rep
oai_identifier_str oai:dspace.auk.edu.kw:11675/5747
publishDate 2019
publisher.none.fl_str_mv International Educative Research Foundation and Publisher (IERFP)
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling 3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human TibiaAlmutairi, MutlaqThis paper presents a standard solid model for human tibia, accounting for the material characteristics of cortical bone, cancellous bone and bone marrow. A CT scan of a cadaveric human tibia was used as the basis of developed model. A total of 201 CT scan slices of the tibia were taken with the distances between the scans varying along the length of the bone with a higher density at the proximal and distal ends, as those were the regions of interest. The data was imported into MIMICS (Materialise), and the threshold method was used to differentiate between the cortical bone region, cancellous bone region, and the bone marrow cavity. The solid model used to generate the FE model is constructed based on CT scan data of an actual cadaveric human tibia. The geometric information is retrieved and edited in (MIMICS). The surfaces defining the cortical bone, the proximal and distal epiphyseal cancellous bone and medullar cavity regions are converted into NURBS surfaces using (GEOMAGIC STUDIO).International Educative Research Foundation and Publisher (IERFP)2020-04-10T14:16:58Z2020-04-10T14:16:58Z2019Journal ArticlePeer-Reviewedinfo:eu-repo/semantics/publishedVersionhttps://dspace.auk.edu.kw/handle/11675/5747https://scholarsjournal.net/index.php/ijier/article/view/1459International Journal for Innovation Education and Research (IJIER)oai:dspace.auk.edu.kw:11675/57472025-08-21T09:05:47Z
spellingShingle 3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human Tibia
Almutairi, Mutlaq
status_str publishedVersion
title 3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human Tibia
title_full 3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human Tibia
title_fullStr 3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human Tibia
title_full_unstemmed 3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human Tibia
title_short 3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human Tibia
title_sort 3d Solid Modeling and Pre-Static Finite Element Modeling of Intact Human Tibia
url https://dspace.auk.edu.kw/handle/11675/5747
https://scholarsjournal.net/index.php/ijier/article/view/1459