Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative

Distributed generation (DG) and solar photovoltaic (PV) systems are just two of the many places multilevel inverters have found a home. The total harmonic distortion (THD) of an inverter's output voltage or current is widely regarded as a useful quality indicator. In order to lessen THD while e...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Arumugam, Mahendran (author)
مؤلفون آخرون: Bostani, Ali (author), Kamal, Mustafa (author), Mehbodniya, Abolfazl (author), Mishra, Ruby (author), Webber, Julian L. (author)
منشور في: 2023
الوصول للمادة أونلاين:http://hdl.handle.net/11675/10956
http://www.scopus.com/inward/record.url?scp=85159633415&partnerID=8YFLogxK
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1870679723196022785
author Arumugam, Mahendran
author2 Bostani, Ali
Kamal, Mustafa
Mehbodniya, Abolfazl
Mishra, Ruby
Webber, Julian L.
author2_role author
author
author
author
author
author_facet Arumugam, Mahendran
Bostani, Ali
Kamal, Mustafa
Mehbodniya, Abolfazl
Mishra, Ruby
Webber, Julian L.
author_role author
dc.creator.none.fl_str_mv Arumugam, Mahendran
Bostani, Ali
Kamal, Mustafa
Mehbodniya, Abolfazl
Mishra, Ruby
Webber, Julian L.
dc.date.none.fl_str_mv 2023-07-01
2024-02-05T08:32:43Z
2024-02-05T08:32:43Z
dc.identifier.none.fl_str_mv 10.1016/j.compeleceng.2023.108744
http://hdl.handle.net/11675/10956
http://www.scopus.com/inward/record.url?scp=85159633415&partnerID=8YFLogxK
dc.publisher.none.fl_str_mv Elsevier Ltd.
dc.relation.none.fl_str_mv Electrical and Computer Engineering
Computers and Electrical Engineering
dc.title.none.fl_str_mv Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative
dc.type.none.fl_str_mv Journal Article
info:eu-repo/semantics/publishedVersion
description Distributed generation (DG) and solar photovoltaic (PV) systems are just two of the many places multilevel inverters have found a home. The total harmonic distortion (THD) of an inverter's output voltage or current is widely regarded as a useful quality indicator. In order to lessen THD while enhancing the performance of the network, the authors of this research presented a unified controller.An integrated controller consisting of PID (Proportional-Integral-Derivative),Fuzzy,and Artificial Neural Network (ANN) controllers is used in the 31-level multilevel inverter to reduce THD in the PV system. The fundamental frequency of the suggested integrated controller is 50 Hz,and the simulation results show that the THD is reduced to 0.94 percent. The proposed controller's performance shown a considerable decrease in 5th order harmonics for the Cascaded H-bridge Multilevel Inverter,as well as an average percentage reduction in line voltage total harmonic distortion of 17.04 compared to the existing approach.
id AUKR_eee85bcba125fe3952f4f3fa21236c7d
identifier_str_mv 10.1016/j.compeleceng.2023.108744
network_acronym_str AUKR
network_name_str AU Kuwait Rep
oai_identifier_str oai:dspace.auk.edu.kw:11675/10956
publishDate 2023
publisher.none.fl_str_mv Elsevier Ltd.
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivativeArumugam, MahendranBostani, AliKamal, MustafaMehbodniya, AbolfazlMishra, RubyWebber, Julian L.Distributed generation (DG) and solar photovoltaic (PV) systems are just two of the many places multilevel inverters have found a home. The total harmonic distortion (THD) of an inverter's output voltage or current is widely regarded as a useful quality indicator. In order to lessen THD while enhancing the performance of the network, the authors of this research presented a unified controller.An integrated controller consisting of PID (Proportional-Integral-Derivative),Fuzzy,and Artificial Neural Network (ANN) controllers is used in the 31-level multilevel inverter to reduce THD in the PV system. The fundamental frequency of the suggested integrated controller is 50 Hz,and the simulation results show that the THD is reduced to 0.94 percent. The proposed controller's performance shown a considerable decrease in 5th order harmonics for the Cascaded H-bridge Multilevel Inverter,as well as an average percentage reduction in line voltage total harmonic distortion of 17.04 compared to the existing approach.Elsevier Ltd.2024-02-05T08:32:43Z2024-02-05T08:32:43Z2023-07-01Journal Articleinfo:eu-repo/semantics/publishedVersion10.1016/j.compeleceng.2023.108744http://hdl.handle.net/11675/10956http://www.scopus.com/inward/record.url?scp=85159633415&partnerID=8YFLogxKElectrical and Computer EngineeringComputers and Electrical Engineeringoai:dspace.auk.edu.kw:11675/109562024-02-05T08:32:43Z
spellingShingle Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative
Arumugam, Mahendran
status_str publishedVersion
title Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative
title_full Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative
title_fullStr Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative
title_full_unstemmed Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative
title_short Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative
title_sort Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative
url http://hdl.handle.net/11675/10956
http://www.scopus.com/inward/record.url?scp=85159633415&partnerID=8YFLogxK