Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative
Distributed generation (DG) and solar photovoltaic (PV) systems are just two of the many places multilevel inverters have found a home. The total harmonic distortion (THD) of an inverter's output voltage or current is widely regarded as a useful quality indicator. In order to lessen THD while e...
محفوظ في:
| المؤلف الرئيسي: | |
|---|---|
| مؤلفون آخرون: | , , , , |
| منشور في: |
2023
|
| الوصول للمادة أونلاين: | http://hdl.handle.net/11675/10956 http://www.scopus.com/inward/record.url?scp=85159633415&partnerID=8YFLogxK |
| الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
| _version_ | 1870679723196022785 |
|---|---|
| author | Arumugam, Mahendran |
| author2 | Bostani, Ali Kamal, Mustafa Mehbodniya, Abolfazl Mishra, Ruby Webber, Julian L. |
| author2_role | author author author author author |
| author_facet | Arumugam, Mahendran Bostani, Ali Kamal, Mustafa Mehbodniya, Abolfazl Mishra, Ruby Webber, Julian L. |
| author_role | author |
| dc.creator.none.fl_str_mv | Arumugam, Mahendran Bostani, Ali Kamal, Mustafa Mehbodniya, Abolfazl Mishra, Ruby Webber, Julian L. |
| dc.date.none.fl_str_mv | 2023-07-01 2024-02-05T08:32:43Z 2024-02-05T08:32:43Z |
| dc.identifier.none.fl_str_mv | 10.1016/j.compeleceng.2023.108744 http://hdl.handle.net/11675/10956 http://www.scopus.com/inward/record.url?scp=85159633415&partnerID=8YFLogxK |
| dc.publisher.none.fl_str_mv | Elsevier Ltd. |
| dc.relation.none.fl_str_mv | Electrical and Computer Engineering Computers and Electrical Engineering |
| dc.title.none.fl_str_mv | Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative |
| dc.type.none.fl_str_mv | Journal Article info:eu-repo/semantics/publishedVersion |
| description | Distributed generation (DG) and solar photovoltaic (PV) systems are just two of the many places multilevel inverters have found a home. The total harmonic distortion (THD) of an inverter's output voltage or current is widely regarded as a useful quality indicator. In order to lessen THD while enhancing the performance of the network, the authors of this research presented a unified controller.An integrated controller consisting of PID (Proportional-Integral-Derivative),Fuzzy,and Artificial Neural Network (ANN) controllers is used in the 31-level multilevel inverter to reduce THD in the PV system. The fundamental frequency of the suggested integrated controller is 50 Hz,and the simulation results show that the THD is reduced to 0.94 percent. The proposed controller's performance shown a considerable decrease in 5th order harmonics for the Cascaded H-bridge Multilevel Inverter,as well as an average percentage reduction in line voltage total harmonic distortion of 17.04 compared to the existing approach. |
| id | AUKR_eee85bcba125fe3952f4f3fa21236c7d |
| identifier_str_mv | 10.1016/j.compeleceng.2023.108744 |
| network_acronym_str | AUKR |
| network_name_str | AU Kuwait Rep |
| oai_identifier_str | oai:dspace.auk.edu.kw:11675/10956 |
| publishDate | 2023 |
| publisher.none.fl_str_mv | Elsevier Ltd. |
| repository.mail.fl_str_mv | |
| repository.name.fl_str_mv | |
| repository_id_str | |
| spelling | Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivativeArumugam, MahendranBostani, AliKamal, MustafaMehbodniya, AbolfazlMishra, RubyWebber, Julian L.Distributed generation (DG) and solar photovoltaic (PV) systems are just two of the many places multilevel inverters have found a home. The total harmonic distortion (THD) of an inverter's output voltage or current is widely regarded as a useful quality indicator. In order to lessen THD while enhancing the performance of the network, the authors of this research presented a unified controller.An integrated controller consisting of PID (Proportional-Integral-Derivative),Fuzzy,and Artificial Neural Network (ANN) controllers is used in the 31-level multilevel inverter to reduce THD in the PV system. The fundamental frequency of the suggested integrated controller is 50 Hz,and the simulation results show that the THD is reduced to 0.94 percent. The proposed controller's performance shown a considerable decrease in 5th order harmonics for the Cascaded H-bridge Multilevel Inverter,as well as an average percentage reduction in line voltage total harmonic distortion of 17.04 compared to the existing approach.Elsevier Ltd.2024-02-05T08:32:43Z2024-02-05T08:32:43Z2023-07-01Journal Articleinfo:eu-repo/semantics/publishedVersion10.1016/j.compeleceng.2023.108744http://hdl.handle.net/11675/10956http://www.scopus.com/inward/record.url?scp=85159633415&partnerID=8YFLogxKElectrical and Computer EngineeringComputers and Electrical Engineeringoai:dspace.auk.edu.kw:11675/109562024-02-05T08:32:43Z |
| spellingShingle | Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative Arumugam, Mahendran |
| status_str | publishedVersion |
| title | Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative |
| title_full | Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative |
| title_fullStr | Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative |
| title_full_unstemmed | Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative |
| title_short | Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative |
| title_sort | Total harmonic distortion reduction based energy harvesting using grid-based three phase system and integral-derivative |
| url | http://hdl.handle.net/11675/10956 http://www.scopus.com/inward/record.url?scp=85159633415&partnerID=8YFLogxK |