Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases

Praseodymium ion selective polyvinyl chloride (PVC) membrane sensors, based on two new Schiff’s bases 1,3-diphenylpropane-1,3-diylidenebis(azan-1-ylidene)diphenol (M1) and N,N�-bis(pyridoxylideneiminato) ethylene (M2) have been developed and studied. The sensor having membrane composition of PVC: o-...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Gupta, Vinod K. (author)
مؤلفون آخرون: Goyal, Rajendra N. (author), Manoj K., Pal (author), Ram A., Sharma (author), unknown (author)
التنسيق: article
منشور في: 2009
الموضوعات:
الوصول للمادة أونلاين:https://eprints.kfupm.edu.sa/id/eprint/136159/1/aca3.pdf
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513384557314048
author Gupta, Vinod K.
author2 Goyal, Rajendra N.
Manoj K., Pal
Ram A., Sharma
unknown
author2_role author
author
author
author
author_facet Gupta, Vinod K.
Goyal, Rajendra N.
Manoj K., Pal
Ram A., Sharma
unknown
author_role author
dc.creator.none.fl_str_mv Gupta, Vinod K.
Goyal, Rajendra N.
Manoj K., Pal
Ram A., Sharma
unknown
dc.date.none.fl_str_mv 2009-09-09
2020
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/136159/1/aca3.pdf
(2009) Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases. Analytica Chimica Acta.
dc.language.none.fl_str_mv en
dc.relation.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/136159/
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Chemistry
dc.title.none.fl_str_mv Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases
dc.type.none.fl_str_mv Article
PeerReviewed
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Praseodymium ion selective polyvinyl chloride (PVC) membrane sensors, based on two new Schiff’s bases 1,3-diphenylpropane-1,3-diylidenebis(azan-1-ylidene)diphenol (M1) and N,N�-bis(pyridoxylideneiminato) ethylene (M2) have been developed and studied. The sensor having membrane composition of PVC: o-NPOE: ionophore (M1): NaTPB (w/w; mg) of 150: 300: 8: 5 showed best performances in comparison to M2 based membranes. The sensor based on (M1) exhibits the working concentration range 1.0×10−8 to 1.0×10−2M with a detection limit of 5.0×10−9M and a Nernstian slope 20.0±0.3mVdecade−1 of activity. It exhibited a quick response time as <8 s and its potential responses were pH independent across the range of 3.5–8.5.The influence of the membrane composition and possible interfering ions have also been investigated on the response properties of the electrode. The sensor has been found to work satisfactorily in partially non-aqueous media up to 15% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients determined by using fixed interference method (FIM) indicate high selectivity for praseodymium(III) ions over wide variety of other cations. To asses its analytical applicability the prepared sensor was successfully applied for determination of praseodymium(III) in spiked water samples.
eu_rights_str_mv openAccess
format article
id KFUPM_0bbb1e3e75045c87f15d7dd8a0f4d346
identifier_str_mv (2009) Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases. Analytica Chimica Acta.
language_invalid_str_mv en
network_acronym_str KFUPM
network_name_str King Fahd University of Petroleum and Minerals
oai_identifier_str oai::136159
publishDate 2009
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s basesGupta, Vinod K.Goyal, Rajendra N.Manoj K., PalRam A., SharmaunknownChemistryPraseodymium ion selective polyvinyl chloride (PVC) membrane sensors, based on two new Schiff’s bases 1,3-diphenylpropane-1,3-diylidenebis(azan-1-ylidene)diphenol (M1) and N,N�-bis(pyridoxylideneiminato) ethylene (M2) have been developed and studied. The sensor having membrane composition of PVC: o-NPOE: ionophore (M1): NaTPB (w/w; mg) of 150: 300: 8: 5 showed best performances in comparison to M2 based membranes. The sensor based on (M1) exhibits the working concentration range 1.0×10−8 to 1.0×10−2M with a detection limit of 5.0×10−9M and a Nernstian slope 20.0±0.3mVdecade−1 of activity. It exhibited a quick response time as <8 s and its potential responses were pH independent across the range of 3.5–8.5.The influence of the membrane composition and possible interfering ions have also been investigated on the response properties of the electrode. The sensor has been found to work satisfactorily in partially non-aqueous media up to 15% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients determined by using fixed interference method (FIM) indicate high selectivity for praseodymium(III) ions over wide variety of other cations. To asses its analytical applicability the prepared sensor was successfully applied for determination of praseodymium(III) in spiked water samples.2009-09-092020ArticlePeerReviewedinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://eprints.kfupm.edu.sa/id/eprint/136159/1/aca3.pdf (2009) Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases. Analytica Chimica Acta. enhttps://eprints.kfupm.edu.sa/id/eprint/136159/info:eu-repo/semantics/openAccessoai::1361592019-11-01T14:11:16Z
spellingShingle Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases
Gupta, Vinod K.
Chemistry
status_str publishedVersion
title Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases
title_full Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases
title_fullStr Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases
title_full_unstemmed Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases
title_short Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases
title_sort Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff’s bases
topic Chemistry
url https://eprints.kfupm.edu.sa/id/eprint/136159/1/aca3.pdf