Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement

To enhance power system transient stability, shunt FACTS devices can be controlled in discontinuous mode or in a combination of discontinuous and continuous mode. In continuous mode proportional controller is usually used. This paper investigates the performance of others controllers in continuous m...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Alam, Ahsanul (author)
مؤلفون آخرون: unknown (author)
التنسيق: article
منشور في: 2007
الموضوعات:
الوصول للمادة أونلاين:https://eprints.kfupm.edu.sa/id/eprint/551/1/PowerTech2007_379.pdf
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513388833406976
author Alam, Ahsanul
author2 unknown
author2_role author
author_facet Alam, Ahsanul
unknown
author_role author
dc.creator.none.fl_str_mv Alam, Ahsanul
unknown
dc.date.none.fl_str_mv 2007-07-05
2020
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/551/1/PowerTech2007_379.pdf
(2007) Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement. PowerTech 2007.
dc.language.none.fl_str_mv en
dc.publisher.none.fl_str_mv PowerTech 2007, Lausanne, Switzerland
dc.relation.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/551/
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Electrical
dc.title.none.fl_str_mv Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement
dc.type.none.fl_str_mv Article
PeerReviewed
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description To enhance power system transient stability, shunt FACTS devices can be controlled in discontinuous mode or in a combination of discontinuous and continuous mode. In continuous mode proportional controller is usually used. This paper investigates the performance of others controllers in continuous mode. Two additional controllers – PI and lead-lag, have been considered. Controller parameter values have been optimized for minimum settling time. This study shows that both PI and lead-lag controllers have good potential for improving critical clearing time. It also shows that properly selected controller parameter values can reduce settling time significantly. The obtained results are verified using non-linear time-domain simulation for both single-machine infinite-bus (SMIB) and multi-machine (10 machine 39 bus) case.
eu_rights_str_mv openAccess
format article
id KFUPM_4844acd181ffa1996092256e1dd703fc
identifier_str_mv (2007) Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement. PowerTech 2007.
language_invalid_str_mv en
network_acronym_str KFUPM
network_name_str King Fahd University of Petroleum and Minerals
oai_identifier_str oai::551
publishDate 2007
publisher.none.fl_str_mv PowerTech 2007, Lausanne, Switzerland
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability ImprovementAlam, AhsanulunknownElectricalTo enhance power system transient stability, shunt FACTS devices can be controlled in discontinuous mode or in a combination of discontinuous and continuous mode. In continuous mode proportional controller is usually used. This paper investigates the performance of others controllers in continuous mode. Two additional controllers – PI and lead-lag, have been considered. Controller parameter values have been optimized for minimum settling time. This study shows that both PI and lead-lag controllers have good potential for improving critical clearing time. It also shows that properly selected controller parameter values can reduce settling time significantly. The obtained results are verified using non-linear time-domain simulation for both single-machine infinite-bus (SMIB) and multi-machine (10 machine 39 bus) case.PowerTech 2007, Lausanne, Switzerland2007-07-052020ArticlePeerReviewedinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://eprints.kfupm.edu.sa/id/eprint/551/1/PowerTech2007_379.pdf (2007) Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement. PowerTech 2007. enhttps://eprints.kfupm.edu.sa/id/eprint/551/info:eu-repo/semantics/openAccessoai::5512019-11-01T13:24:21Z
spellingShingle Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement
Alam, Ahsanul
Electrical
status_str publishedVersion
title Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement
title_full Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement
title_fullStr Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement
title_full_unstemmed Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement
title_short Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement
title_sort Parameter Optimization of Shunt FACTS Controllers for Power System Transient Stability Improvement
topic Electrical