EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS

Air quality in buildings is increasingly becoming an area of great concern because of its profound impact on occupants comfort, health and productivity. In most buildings, poor Indoor Air Quality (IAQ) can be attributed to the presence of indoor-generated pollutants and the reduced ventilation effec...

Full description

Saved in:
Bibliographic Details
Main Author: Khan, Raza A. (author)
Other Authors: Budaiwi, Ismail M. (author), unknown (author)
Format: article
Published: 2020
Online Access:https://eprints.kfupm.edu.sa/id/eprint/1558/1/P129.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1864513400581652480
author Khan, Raza A.
author2 Budaiwi, Ismail M.
unknown
author2_role author
author
author_facet Khan, Raza A.
Budaiwi, Ismail M.
unknown
author_role author
dc.creator.none.fl_str_mv Khan, Raza A.
Budaiwi, Ismail M.
unknown
dc.date.*.fl_str_mv 2020
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/1558/1/P129.pdf
EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS. The 6th Saudi Engineering Conference, KFUPM, Dhahran, December 2002.
dc.language.none.fl_str_mv en
dc.relation.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/1558/
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.title.none.fl_str_mv EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS
dc.type.none.fl_str_mv Article
PeerReviewed
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Air quality in buildings is increasingly becoming an area of great concern because of its profound impact on occupants comfort, health and productivity. In most buildings, poor Indoor Air Quality (IAQ) can be attributed to the presence of indoor-generated pollutants and the reduced ventilation effectiveness. Recent technological advances and developments in building materials and activities have introduced numerous new pollutants to the indoor space. Additionally, trends to conserve energy and make buildings thermally more comfortable have resulted in airtight buildings, hence allowing little air leakage through their envelopes. This has resulted in the reduction or the elimination of the natural dilution process by outdoor air and increased reliance on the Heating Ventilation and Air Conditioning (HVAC) systems to dilute indoor-generated contaminants. The objective of this paper is to assess the air quality in selected commercial and office buildings in the Eastern Province of Saudi Arabia and to identify measures and considerations during building design and operation for enhancing the effectiveness of HVAC systems for better indoor air quality. Questionnaire surveys and interviews were conducted with the building occupants to assess their level of comfort. Furthermore, walk-through inspections and environmental parameters measurements were carried out in those buildings. Based upon the outcome of the analysis of the study, general guidelines have been formulated for HVAC systems design, operation & maintenance for improved IAQ in hot and humid climates of Saudi Arabia. A checklist was also developed for the evaluation of HVAC systems design, operation & maintenance to ensure proper IAQ requirements.
eu_rights_str_mv openAccess
format article
id KFUPM_6b6322e8f1f5a1603fa20427da9bf727
identifier_str_mv EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS. The 6th Saudi Engineering Conference, KFUPM, Dhahran, December 2002.
language_invalid_str_mv en
network_acronym_str KFUPM
network_name_str King Fahd University of Petroleum and Minerals
oai_identifier_str oai::1558
publishDate 2020
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMSKhan, Raza A.Budaiwi, Ismail M.unknownAir quality in buildings is increasingly becoming an area of great concern because of its profound impact on occupants comfort, health and productivity. In most buildings, poor Indoor Air Quality (IAQ) can be attributed to the presence of indoor-generated pollutants and the reduced ventilation effectiveness. Recent technological advances and developments in building materials and activities have introduced numerous new pollutants to the indoor space. Additionally, trends to conserve energy and make buildings thermally more comfortable have resulted in airtight buildings, hence allowing little air leakage through their envelopes. This has resulted in the reduction or the elimination of the natural dilution process by outdoor air and increased reliance on the Heating Ventilation and Air Conditioning (HVAC) systems to dilute indoor-generated contaminants. The objective of this paper is to assess the air quality in selected commercial and office buildings in the Eastern Province of Saudi Arabia and to identify measures and considerations during building design and operation for enhancing the effectiveness of HVAC systems for better indoor air quality. Questionnaire surveys and interviews were conducted with the building occupants to assess their level of comfort. Furthermore, walk-through inspections and environmental parameters measurements were carried out in those buildings. Based upon the outcome of the analysis of the study, general guidelines have been formulated for HVAC systems design, operation & maintenance for improved IAQ in hot and humid climates of Saudi Arabia. A checklist was also developed for the evaluation of HVAC systems design, operation & maintenance to ensure proper IAQ requirements.ArticlePeerReviewedinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://eprints.kfupm.edu.sa/id/eprint/1558/1/P129.pdf EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS. The 6th Saudi Engineering Conference, KFUPM, Dhahran, December 2002. enhttps://eprints.kfupm.edu.sa/id/eprint/1558/2020info:eu-repo/semantics/openAccessoai::15582019-11-01T13:27:17Z
spellingShingle EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS
Khan, Raza A.
status_str publishedVersion
title EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS
title_full EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS
title_fullStr EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS
title_full_unstemmed EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS
title_short EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS
title_sort EVALUATION OF INDOOR AIR QUALITY STATUS IN SELECTED COMMERCIAL BUILDINGS IN SAUDI ARABIA: ROLE OF THE HVAC SYSTEMS
url https://eprints.kfupm.edu.sa/id/eprint/1558/1/P129.pdf