A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines

Electric utilities are striving to improve the appearance of distribution lines, apply different combinations of insulating components to establish the necessary insulation for such lines, by the use of new insulators and simultaneously reduce lightning outages. The impulse critical flashover (CFO)...

Full description

Saved in:
Bibliographic Details
Main Author: Shwehdi, M.H. (author)
Other Authors: Shahzad, F. (author), unknown (author)
Format: article
Published: 1996
Subjects:
Online Access:https://eprints.kfupm.edu.sa/id/eprint/14427/1/14427_1.pdf
https://eprints.kfupm.edu.sa/id/eprint/14427/2/14427_2.doc
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1864513393764859904
author Shwehdi, M.H.
author2 Shahzad, F.
unknown
author2_role author
author
author_facet Shwehdi, M.H.
Shahzad, F.
unknown
author_role author
dc.creator.none.fl_str_mv Shwehdi, M.H.
Shahzad, F.
unknown
dc.date.none.fl_str_mv 1996-06
2020
dc.format.none.fl_str_mv application/pdf
application/msword
dc.identifier.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/14427/1/14427_1.pdf
https://eprints.kfupm.edu.sa/id/eprint/14427/2/14427_2.doc
(1996) A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines. Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on, 1.
dc.language.none.fl_str_mv en
en
dc.publisher.none.fl_str_mv IEEE
dc.relation.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/14427/
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Computer
dc.title.none.fl_str_mv A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines
dc.type.none.fl_str_mv Article
PeerReviewed
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Electric utilities are striving to improve the appearance of distribution lines, apply different combinations of insulating components to establish the necessary insulation for such lines, by the use of new insulators and simultaneously reduce lightning outages. The impulse critical flashover (CFO) voltages of many overhead line insulators are determined for single and multiple (porcelain, fiberglass, polymers and wood). Laboratory investigation and studies relating to the evaluation of CFO values of distribution lines for multiple dielectrics are reported. Data used by the industry for transmission lines are not fully applicable to estimate CFOs for distribution lines. Many engineers concerned with the design or operation of high voltage transmission lines have devised methods to estimate the performance of lightning impulse. There is, at present, no such method available on estimating the insulation strengths of multiple dielectrics of distribution lines subjected to impulse CFO. This paper presents a method of estimating the CFO insulation strengths of two and three dielectric combinations used on distribution overhead lines using the developed extended multi curves (EMC). The proper use and evaluation of the insulation level by this novel method has a major influence on the design and cost of distribution line construction, application, also improving the performance of specific line designs
eu_rights_str_mv openAccess
format article
id KFUPM_7d5184e021c56824844be109d9e83abb
identifier_str_mv (1996) A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines. Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on, 1.
language_invalid_str_mv en
network_acronym_str KFUPM
network_name_str King Fahd University of Petroleum and Minerals
oai_identifier_str oai::14427
publishDate 1996
publisher.none.fl_str_mv IEEE
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlinesShwehdi, M.H.Shahzad, F.unknownComputerElectric utilities are striving to improve the appearance of distribution lines, apply different combinations of insulating components to establish the necessary insulation for such lines, by the use of new insulators and simultaneously reduce lightning outages. The impulse critical flashover (CFO) voltages of many overhead line insulators are determined for single and multiple (porcelain, fiberglass, polymers and wood). Laboratory investigation and studies relating to the evaluation of CFO values of distribution lines for multiple dielectrics are reported. Data used by the industry for transmission lines are not fully applicable to estimate CFOs for distribution lines. Many engineers concerned with the design or operation of high voltage transmission lines have devised methods to estimate the performance of lightning impulse. There is, at present, no such method available on estimating the insulation strengths of multiple dielectrics of distribution lines subjected to impulse CFO. This paper presents a method of estimating the CFO insulation strengths of two and three dielectric combinations used on distribution overhead lines using the developed extended multi curves (EMC). The proper use and evaluation of the insulation level by this novel method has a major influence on the design and cost of distribution line construction, application, also improving the performance of specific line designsIEEE1996-062020ArticlePeerReviewedinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfapplication/mswordhttps://eprints.kfupm.edu.sa/id/eprint/14427/1/14427_1.pdfhttps://eprints.kfupm.edu.sa/id/eprint/14427/2/14427_2.doc (1996) A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines. Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on, 1. enenhttps://eprints.kfupm.edu.sa/id/eprint/14427/info:eu-repo/semantics/openAccessoai::144272019-11-01T14:05:45Z
spellingShingle A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines
Shwehdi, M.H.
Computer
status_str publishedVersion
title A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines
title_full A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines
title_fullStr A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines
title_full_unstemmed A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines
title_short A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines
title_sort A novel method for predicting critical flashover (CFO) voltagesinsulation strength of multiple dielectrics on distribution overheadlines
topic Computer
url https://eprints.kfupm.edu.sa/id/eprint/14427/1/14427_1.pdf
https://eprints.kfupm.edu.sa/id/eprint/14427/2/14427_2.doc