Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons

The light output of 125-mm-diameter NE213 and NE102A detectors has been measured for neutron energies ranging from 2.7 to 14.5 MeV. For neutron energies below 6.14 MeV, measurements were carried out using the neutron time-of-flight spectrum from an Am-Be neutron source, while for proton energies abo...

Full description

Saved in:
Bibliographic Details
Main Author: Naqvi, A.A. (author)
Other Authors: Khiari, F.Z. (author), Coban, A. (author), Aksoy, A. (author), Al-Jalal, M.A. (author), Raashid, M. (author), unknown (author)
Format: article
Published: 1992
Subjects:
Online Access:https://eprints.kfupm.edu.sa/id/eprint/14689/1/14689_1.pdf
https://eprints.kfupm.edu.sa/id/eprint/14689/2/14689_2.doc
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1864513384472379392
author Naqvi, A.A.
author2 Khiari, F.Z.
Coban, A.
Aksoy, A.
Al-Jalal, M.A.
Raashid, M.
unknown
author2_role author
author
author
author
author
author
author_facet Naqvi, A.A.
Khiari, F.Z.
Coban, A.
Aksoy, A.
Al-Jalal, M.A.
Raashid, M.
unknown
author_role author
dc.creator.none.fl_str_mv Naqvi, A.A.
Khiari, F.Z.
Coban, A.
Aksoy, A.
Al-Jalal, M.A.
Raashid, M.
unknown
dc.date.none.fl_str_mv 1992-10
2020
dc.format.none.fl_str_mv application/pdf
application/msword
dc.identifier.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/14689/1/14689_1.pdf
https://eprints.kfupm.edu.sa/id/eprint/14689/2/14689_2.doc
(1992) Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons. Nuclear Science Symposium and Medical Imaging Conference, 1992., Conference Record of the 1992 IEEE, 1.
dc.language.none.fl_str_mv en
en
dc.publisher.none.fl_str_mv IEEE
dc.relation.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/14689/
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Computer
dc.title.none.fl_str_mv Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons
dc.type.none.fl_str_mv Article
PeerReviewed
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description The light output of 125-mm-diameter NE213 and NE102A detectors has been measured for neutron energies ranging from 2.7 to 14.5 MeV. For neutron energies below 6.14 MeV, measurements were carried out using the neutron time-of-flight spectrum from an Am-Be neutron source, while for proton energies above 6.14 MeV, measurements were carried out using neutrons produced from the T(d,n) reaction. For the NE102A detector the measured light output is in good agreement with the data of R.A. Cecil et al., (1979) but for the NE213 detector the light output is 2-15% lower than that for a similar detector. The NE213 detector light output agrees with the data of V. Verbinski et al. (1968)
eu_rights_str_mv openAccess
format article
id KFUPM_8d2f33bfe0e97446c3d0621faa55c30d
identifier_str_mv (1992) Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons. Nuclear Science Symposium and Medical Imaging Conference, 1992., Conference Record of the 1992 IEEE, 1.
language_invalid_str_mv en
network_acronym_str KFUPM
network_name_str King Fahd University of Petroleum and Minerals
oai_identifier_str oai::14689
publishDate 1992
publisher.none.fl_str_mv IEEE
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutronsNaqvi, A.A.Khiari, F.Z.Coban, A.Aksoy, A.Al-Jalal, M.A.Raashid, M.unknownComputerThe light output of 125-mm-diameter NE213 and NE102A detectors has been measured for neutron energies ranging from 2.7 to 14.5 MeV. For neutron energies below 6.14 MeV, measurements were carried out using the neutron time-of-flight spectrum from an Am-Be neutron source, while for proton energies above 6.14 MeV, measurements were carried out using neutrons produced from the T(d,n) reaction. For the NE102A detector the measured light output is in good agreement with the data of R.A. Cecil et al., (1979) but for the NE213 detector the light output is 2-15% lower than that for a similar detector. The NE213 detector light output agrees with the data of V. Verbinski et al. (1968)IEEE1992-102020ArticlePeerReviewedinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfapplication/mswordhttps://eprints.kfupm.edu.sa/id/eprint/14689/1/14689_1.pdfhttps://eprints.kfupm.edu.sa/id/eprint/14689/2/14689_2.doc (1992) Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons. Nuclear Science Symposium and Medical Imaging Conference, 1992., Conference Record of the 1992 IEEE, 1. enenhttps://eprints.kfupm.edu.sa/id/eprint/14689/info:eu-repo/semantics/openAccessoai::146892019-11-01T14:06:57Z
spellingShingle Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons
Naqvi, A.A.
Computer
status_str publishedVersion
title Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons
title_full Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons
title_fullStr Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons
title_full_unstemmed Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons
title_short Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons
title_sort Measurement of light output of NE213 and NE102A detectors for2.7-14.5 MeV neutrons
topic Computer
url https://eprints.kfupm.edu.sa/id/eprint/14689/1/14689_1.pdf
https://eprints.kfupm.edu.sa/id/eprint/14689/2/14689_2.doc