THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS

Increased awareness of the impact of chlorofluorocarbons (CFCs) on the global environment has become the impetus in searching for alternative refrigerants and cooling methods for automotive air conditioning. Automotive air conditioning is one industry that heavily uses CFC compounds, and the leakage...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Al-Aqeeli, N. (author)
مؤلفون آخرون: Gandhidasan, P. (author), unknown (author)
التنسيق: article
منشور في: 2020
الموضوعات:
الوصول للمادة أونلاين:https://eprints.kfupm.edu.sa/id/eprint/1711/1/P517.pdf
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513389907148800
author Al-Aqeeli, N.
author2 Gandhidasan, P.
unknown
author2_role author
author
author_facet Al-Aqeeli, N.
Gandhidasan, P.
unknown
author_role author
dc.creator.none.fl_str_mv Al-Aqeeli, N.
Gandhidasan, P.
unknown
dc.date.*.fl_str_mv 2020
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/1711/1/P517.pdf
THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS. The 6th Saudi Engineering Conference, KFUPM, Dhahran, December 2002.
dc.language.none.fl_str_mv en
dc.relation.none.fl_str_mv https://eprints.kfupm.edu.sa/id/eprint/1711/
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Mechanical
dc.title.none.fl_str_mv THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS
dc.type.none.fl_str_mv Article
PeerReviewed
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Increased awareness of the impact of chlorofluorocarbons (CFCs) on the global environment has become the impetus in searching for alternative refrigerants and cooling methods for automotive air conditioning. Automotive air conditioning is one industry that heavily uses CFC compounds, and the leakage of CFCs from such air conditioners is substantial compared to that from stationary air conditioners. Therefore, the use of non-CFC air conditioners in automobiles is apparently becoming very important. The main objective of this paper is to study the feasibility and design of an air conditioning system for automobiles using the Open Cycle Absorption System, with LiBr-H2O as the working fluid. Also, some suggestions are given to minimize the power loss like making use of the exhaust gas to pre-heat the weak desiccant. Evaluating the COP, of the designed air conditioning system for buses is the main scope, and it is found that the COP of the system is increasing with the increase in regeneration temperature at fixed evaporator and absorber temperatures. The system components are plotted in a schematic and flow chart as well as psychometric chart showing the complete process of conditioning and dehumidifying air.
eu_rights_str_mv openAccess
format article
id KFUPM_b691bea25199894f1f7a613d21b7fea6
identifier_str_mv THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS. The 6th Saudi Engineering Conference, KFUPM, Dhahran, December 2002.
language_invalid_str_mv en
network_acronym_str KFUPM
network_name_str King Fahd University of Petroleum and Minerals
oai_identifier_str oai::1711
publishDate 2020
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCSAl-Aqeeli, N.Gandhidasan, P.unknownMechanicalIncreased awareness of the impact of chlorofluorocarbons (CFCs) on the global environment has become the impetus in searching for alternative refrigerants and cooling methods for automotive air conditioning. Automotive air conditioning is one industry that heavily uses CFC compounds, and the leakage of CFCs from such air conditioners is substantial compared to that from stationary air conditioners. Therefore, the use of non-CFC air conditioners in automobiles is apparently becoming very important. The main objective of this paper is to study the feasibility and design of an air conditioning system for automobiles using the Open Cycle Absorption System, with LiBr-H2O as the working fluid. Also, some suggestions are given to minimize the power loss like making use of the exhaust gas to pre-heat the weak desiccant. Evaluating the COP, of the designed air conditioning system for buses is the main scope, and it is found that the COP of the system is increasing with the increase in regeneration temperature at fixed evaporator and absorber temperatures. The system components are plotted in a schematic and flow chart as well as psychometric chart showing the complete process of conditioning and dehumidifying air.ArticlePeerReviewedinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://eprints.kfupm.edu.sa/id/eprint/1711/1/P517.pdf THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS. The 6th Saudi Engineering Conference, KFUPM, Dhahran, December 2002. enhttps://eprints.kfupm.edu.sa/id/eprint/1711/2020info:eu-repo/semantics/openAccessoai::17112019-11-01T13:27:42Z
spellingShingle THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS
Al-Aqeeli, N.
Mechanical
status_str publishedVersion
title THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS
title_full THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS
title_fullStr THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS
title_full_unstemmed THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS
title_short THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS
title_sort THE USE OF AN OPEN CYCLE ABSORPTION SYSTEM IN AUTOMOBILES AS AN ALTERNATIVE TO CFCS
topic Mechanical
url https://eprints.kfupm.edu.sa/id/eprint/1711/1/P517.pdf