Induced voltages on fence wires and pipe lines by AC powertransmission lines
A method is developed for calculating the induced voltages on fence wires and pipelines underneath AC power transmission lines. The method is based on the charge simulation techniques and takes into account disturbances of the electric field and potential due to the presence of the fence wire or pip...
Saved in:
| Main Author: | |
|---|---|
| Other Authors: | , |
| Format: | article |
| Published: |
1992
|
| Subjects: | |
| Online Access: | https://eprints.kfupm.edu.sa/id/eprint/14432/1/14432_1.pdf https://eprints.kfupm.edu.sa/id/eprint/14432/2/14432_2.doc |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1864513393768005632 |
|---|---|
| author | Abdel-Salam, M.M. |
| author2 | Al-Shehri, A.M. unknown |
| author2_role | author author |
| author_facet | Abdel-Salam, M.M. Al-Shehri, A.M. unknown |
| author_role | author |
| dc.creator.none.fl_str_mv | Abdel-Salam, M.M. Al-Shehri, A.M. unknown |
| dc.date.none.fl_str_mv | 1992-10 2020 |
| dc.format.none.fl_str_mv | application/pdf application/msword |
| dc.identifier.none.fl_str_mv | https://eprints.kfupm.edu.sa/id/eprint/14432/1/14432_1.pdf https://eprints.kfupm.edu.sa/id/eprint/14432/2/14432_2.doc (1992) Induced voltages on fence wires and pipe lines by AC powertransmission lines. Industry Applications Society Annual Meeting, 1992., Conference Record of the 1992 IEEE, 1. |
| dc.language.none.fl_str_mv | en en |
| dc.publisher.none.fl_str_mv | IEEE |
| dc.relation.none.fl_str_mv | https://eprints.kfupm.edu.sa/id/eprint/14432/ |
| dc.rights.*.fl_str_mv | info:eu-repo/semantics/openAccess |
| dc.subject.none.fl_str_mv | Computer |
| dc.title.none.fl_str_mv | Induced voltages on fence wires and pipe lines by AC powertransmission lines |
| dc.type.none.fl_str_mv | Article PeerReviewed info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/article |
| description | A method is developed for calculating the induced voltages on fence wires and pipelines underneath AC power transmission lines. The method is based on the charge simulation techniques and takes into account disturbances of the electric field and potential due to the presence of the fence wire or pipeline underneath the line. The calculated and previously measured induced voltages on fence wires are compared. Induced voltages on pipelines underneath 230 and 380 kV lines were measured. The results are correlated with the calculated values and discussed in the light of electric field induction on objects adjacent to AC power transmission lines |
| eu_rights_str_mv | openAccess |
| format | article |
| id | KFUPM_cc13a51aae03488a53fb4e7ff3c489ff |
| identifier_str_mv | (1992) Induced voltages on fence wires and pipe lines by AC powertransmission lines. Industry Applications Society Annual Meeting, 1992., Conference Record of the 1992 IEEE, 1. |
| language_invalid_str_mv | en |
| network_acronym_str | KFUPM |
| network_name_str | King Fahd University of Petroleum and Minerals |
| oai_identifier_str | oai::14432 |
| publishDate | 1992 |
| publisher.none.fl_str_mv | IEEE |
| repository.mail.fl_str_mv | |
| repository.name.fl_str_mv | |
| repository_id_str | |
| spelling | Induced voltages on fence wires and pipe lines by AC powertransmission linesAbdel-Salam, M.M.Al-Shehri, A.M.unknownComputerA method is developed for calculating the induced voltages on fence wires and pipelines underneath AC power transmission lines. The method is based on the charge simulation techniques and takes into account disturbances of the electric field and potential due to the presence of the fence wire or pipeline underneath the line. The calculated and previously measured induced voltages on fence wires are compared. Induced voltages on pipelines underneath 230 and 380 kV lines were measured. The results are correlated with the calculated values and discussed in the light of electric field induction on objects adjacent to AC power transmission linesIEEE1992-102020ArticlePeerReviewedinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfapplication/mswordhttps://eprints.kfupm.edu.sa/id/eprint/14432/1/14432_1.pdfhttps://eprints.kfupm.edu.sa/id/eprint/14432/2/14432_2.doc (1992) Induced voltages on fence wires and pipe lines by AC powertransmission lines. Industry Applications Society Annual Meeting, 1992., Conference Record of the 1992 IEEE, 1. enenhttps://eprints.kfupm.edu.sa/id/eprint/14432/info:eu-repo/semantics/openAccessoai::144322019-11-01T14:05:46Z |
| spellingShingle | Induced voltages on fence wires and pipe lines by AC powertransmission lines Abdel-Salam, M.M. Computer |
| status_str | publishedVersion |
| title | Induced voltages on fence wires and pipe lines by AC powertransmission lines |
| title_full | Induced voltages on fence wires and pipe lines by AC powertransmission lines |
| title_fullStr | Induced voltages on fence wires and pipe lines by AC powertransmission lines |
| title_full_unstemmed | Induced voltages on fence wires and pipe lines by AC powertransmission lines |
| title_short | Induced voltages on fence wires and pipe lines by AC powertransmission lines |
| title_sort | Induced voltages on fence wires and pipe lines by AC powertransmission lines |
| topic | Computer |
| url | https://eprints.kfupm.edu.sa/id/eprint/14432/1/14432_1.pdf https://eprints.kfupm.edu.sa/id/eprint/14432/2/14432_2.doc |