Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease Diagnosis

Detection of myocardial perfusion abnormalities using Tc-99m tetrofosmin was evaluated for sensitivity and specificity compared to coronary angiography. Between January 1996 and January 1998, exercise stress tests and myocardial scintigraphy were performed in 58 patients, followed by coronary angiog...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Ghanem, Georges (author)
مؤلفون آخرون: Tarcha, Walid (author), Sokhn, Kozhaya (author), Hage, Chadi (author), Yatim, Ahmad (author), Chammas, Elie (author)
التنسيق: article
منشور في: 2002
الوصول للمادة أونلاين:http://hdl.handle.net/10725/4042
http://dx.doi.org/10.1177/021849230201000312
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php
http://aan.sagepub.com/content/10/3/244.short
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513462836658176
author Ghanem, Georges
author2 Tarcha, Walid
Sokhn, Kozhaya
Hage, Chadi
Yatim, Ahmad
Chammas, Elie
author2_role author
author
author
author
author
author_facet Ghanem, Georges
Tarcha, Walid
Sokhn, Kozhaya
Hage, Chadi
Yatim, Ahmad
Chammas, Elie
author_role author
dc.creator.none.fl_str_mv Ghanem, Georges
Tarcha, Walid
Sokhn, Kozhaya
Hage, Chadi
Yatim, Ahmad
Chammas, Elie
dc.date.none.fl_str_mv 2002
2016-06-15T08:36:36Z
2016-06-15T08:36:36Z
2016-06-15
dc.identifier.none.fl_str_mv 0218-4923
http://hdl.handle.net/10725/4042
http://dx.doi.org/10.1177/021849230201000312
Chammas, E., Yatim, A., Hage, C., Sokhn, K., Tarcha, W., & Ghanem, G. (2002). Evaluation of Tc-99m tetrofosmin scan for coronary artery disease diagnosis. Asian Cardiovascular and Thoracic Annals, 10(3), 244-247.
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php
http://aan.sagepub.com/content/10/3/244.short
dc.language.none.fl_str_mv en
dc.relation.none.fl_str_mv Asian Cardiovascular and Thoracic Annals
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.title.none.fl_str_mv Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease Diagnosis
dc.type.none.fl_str_mv Article
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Detection of myocardial perfusion abnormalities using Tc-99m tetrofosmin was evaluated for sensitivity and specificity compared to coronary angiography. Between January 1996 and January 1998, exercise stress tests and myocardial scintigraphy were performed in 58 patients, followed by coronary angiography within 2 months. There were 48 males and 10 females, aged 33 to 72 years (mean, 57 years). The sensitivity and specificity of exercise stress tests were 64% and 68%, respectively, while the sensitivity and specificity of Tc-99m tetrofosmin scans were 88% and 75%, respectively, compared to angiography. For Tc-99m tetrofosmin scans, the sensitivity was 78% for the left anterior descending artery, 66% for the left circumflex artery, and 76% for the right coronary artery; specificity was 74% for the left anterior descending artery, 90% for the left circumflex artery, and 75% for the right coronary artery. It was concluded that Tc-99m tetrofosmin allowed high-quality myocardial perfusion imaging with results comparable to those obtained using thallium-201 chloride.
eu_rights_str_mv openAccess
format article
id LAURepo_23bb99c15bbcb21e40260237bd333dd4
identifier_str_mv 0218-4923
Chammas, E., Yatim, A., Hage, C., Sokhn, K., Tarcha, W., & Ghanem, G. (2002). Evaluation of Tc-99m tetrofosmin scan for coronary artery disease diagnosis. Asian Cardiovascular and Thoracic Annals, 10(3), 244-247.
language_invalid_str_mv en
network_acronym_str LAURepo
network_name_str Lebanese American University repository
oai_identifier_str oai:laur.lau.edu.lb:10725/4042
publishDate 2002
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease DiagnosisGhanem, GeorgesTarcha, WalidSokhn, KozhayaHage, ChadiYatim, AhmadChammas, ElieDetection of myocardial perfusion abnormalities using Tc-99m tetrofosmin was evaluated for sensitivity and specificity compared to coronary angiography. Between January 1996 and January 1998, exercise stress tests and myocardial scintigraphy were performed in 58 patients, followed by coronary angiography within 2 months. There were 48 males and 10 females, aged 33 to 72 years (mean, 57 years). The sensitivity and specificity of exercise stress tests were 64% and 68%, respectively, while the sensitivity and specificity of Tc-99m tetrofosmin scans were 88% and 75%, respectively, compared to angiography. For Tc-99m tetrofosmin scans, the sensitivity was 78% for the left anterior descending artery, 66% for the left circumflex artery, and 76% for the right coronary artery; specificity was 74% for the left anterior descending artery, 90% for the left circumflex artery, and 75% for the right coronary artery. It was concluded that Tc-99m tetrofosmin allowed high-quality myocardial perfusion imaging with results comparable to those obtained using thallium-201 chloride.PublishedN/A2016-06-15T08:36:36Z2016-06-15T08:36:36Z20022016-06-15Articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article0218-4923http://hdl.handle.net/10725/4042http://dx.doi.org/10.1177/021849230201000312Chammas, E., Yatim, A., Hage, C., Sokhn, K., Tarcha, W., & Ghanem, G. (2002). Evaluation of Tc-99m tetrofosmin scan for coronary artery disease diagnosis. Asian Cardiovascular and Thoracic Annals, 10(3), 244-247.http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.phphttp://aan.sagepub.com/content/10/3/244.shortenAsian Cardiovascular and Thoracic Annalsinfo:eu-repo/semantics/openAccessoai:laur.lau.edu.lb:10725/40422021-03-19T10:00:52Z
spellingShingle Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease Diagnosis
Ghanem, Georges
status_str publishedVersion
title Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease Diagnosis
title_full Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease Diagnosis
title_fullStr Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease Diagnosis
title_full_unstemmed Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease Diagnosis
title_short Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease Diagnosis
title_sort Evaluation of Tc-99m Tetrofosmin Scan for Coronary Artery Disease Diagnosis
url http://hdl.handle.net/10725/4042
http://dx.doi.org/10.1177/021849230201000312
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php
http://aan.sagepub.com/content/10/3/244.short