Characterization and modeling of the ionomer-conductor interface in ionic polymer

Ionomeric polymer transducers consist of an ion-exchange membrane plated with conductive metal layers on its outer surfaces. Such materials are known to exhibit electromechanical coupling under the application of electric fields and imposed deformation (Oguro et al., 1992; Shahinpoor et al., 1998)....

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Akle, Barbar J. (author)
التنسيق: masterThesis
منشور في: 2005
الوصول للمادة أونلاين:http://hdl.handle.net/10725/6934
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php
https://vtechworks.lib.vt.edu/bitstream/handle/10919/28682/Barbar_Akle_Dissertation_2005.pdf?sequence=1&isAllowed=y
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513481063006208
author Akle, Barbar J.
author_facet Akle, Barbar J.
author_role author
dc.creator.none.fl_str_mv Akle, Barbar J.
dc.date.none.fl_str_mv 2005
2018-01-22T14:34:01Z
2018-01-22T14:34:01Z
2018-01-22
dc.identifier.none.fl_str_mv http://hdl.handle.net/10725/6934
Akle, B. J. (2005). Characterization and modeling of the ionomer-conductor interface in ionic polymer transducers (Doctoral dissertation).
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php
https://vtechworks.lib.vt.edu/bitstream/handle/10919/28682/Barbar_Akle_Dissertation_2005.pdf?sequence=1&isAllowed=y
dc.language.none.fl_str_mv en
dc.publisher.none.fl_str_mv Virginia Polytechnic Institute and State University
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.title.none.fl_str_mv Characterization and modeling of the ionomer-conductor interface in ionic polymer
dc.type.none.fl_str_mv Thesis
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description Ionomeric polymer transducers consist of an ion-exchange membrane plated with conductive metal layers on its outer surfaces. Such materials are known to exhibit electromechanical coupling under the application of electric fields and imposed deformation (Oguro et al., 1992; Shahinpoor et al., 1998). Compared to other types of electromechanical transducers, such as piezoelectric materials, ionomeric transducers have the advantage of high-strain output (> 9% is possible), low-voltage operation (typically less than 5 V), and high sensitivity in the charge-sensing mode. A series of experiments on actuators with various ionic polymers such as Nafion and novel poly(Arylene ether disulphonate) systems (BPS and PATS) and electrode composition demonstrated the existence of a linear correlation between the strain response and the capacitance of the material. This correlation was shown to be independent of the polymer composition and the plating parameters. Due to the fact that the low-frequency capacitance of an ionomer is strongly related to charge accumulation at the electrodes, this correlation suggests a strong relationship between the surface charge accumulation and the mechanical deformation in ionomeric actuators. The strain response of water-hydrated transducers varies from 50 μstrain/V to 750 μstrain/V at 1Hz while the strain-to-charge response is between 9 μstrain and 15 μstrain. This contribution suggests a strong correlation between cationic motion and the strain in the polymer at the ionomer-conductor interface. A novel fabrication technique for ionic polymer transducers was developed for this dissertation for the purpose of quantifying the relationship between electrode composition and transducer performance. It consists of mixing an ionic polymer dispersion (or solution) with a fine conducting powder and attaching it to the membrane as an electrode. The Direct Assembly Process (DAP) allows the use of any type of ionomer, diluent, conducting powder, and counter ion in the transducer, and permits the exploration of any novel polymeric design. Several conducting powders have been incorporated in the electrode including single-walled carbon nanotubes (SWNT), polyaniline (PANI) powders, high surface area RuO2, and carbon black electrodes. The DAP provided the tool which enabled us to study the effect of electrode architecture on performance of ionic polymer transducers. The DAP allows the variation in the electrode architecture which enabled us to fabricate dry transducers with 50x better performance compared to transducers made using the state of the art impregnation-reduction technique. DAP fabricated transducers achieved a strain of 9.4% at a strain rate of 1%/s. Each electrode material had an optimal concentration in the electrode. For RuO2, the optimal loading was approximately 45% by volume. This study also demonstrated that carbon nanotubes electrodes have an optimal performance at loadings around 30 vol%, while PANI electrodes are optimized at 95 vol%. Extensional actuation in ionic polymer transducers was first reported and characterized in this dissertation. An electromechanical coupling model presented by Leo et al. (2005) defined the strain in the active areas as a function of the charge. This model assumed a linear and a quadratic term that produces a nonlinear response for a sine wave actuation input. The quadratic term in the strain generates a zero net bending moment for ionic polymer transducers with symmetric electrodes, while the linear term is canceled in extensional actuation for symmetric electrodes. Experimental results demonstrated strains on the order of 110 μstrain in the thickness direction compared to 1700 μstrain peak to peak on the external fibers for the same transducer, could be achieved when it is allowed to bend under +/-2V potential at 0.5 Hz. Extensional and bending actuation in ionic polymer transducers were explained using a bimorph active area model. Several experiments were performed to compare the bending actuation with the extensional actuation capability. The active area in the model was assumed to be the high surface area electrode. Electric double layer theory states that ions accumulate in a thin boundary layer close to the metal-polymer interface. Since the metal powders are evenly dispersed in the electrode area of the transducer, this area is expected to actuate evenly upon voltage application. This active area model emphasizes the importance the boundary layer on the conductor-ionomer interfacial area. Computing model parameters based on experimental results demonstrated that the active areas model collapses the bending data from a maximum variation of 200% for the strain per charge, to less than 68% for the model linear term. Furthermore, the model successfully predicted bending response from parameters computed using thickness experimental results. The prediction was particularly precise in estimating the trends of non-linearity as a function of the amount of asymmetry between the two electrodes.
eu_rights_str_mv openAccess
format masterThesis
id LAURepo_d630c3af325ddd31e5880bbd175100de
identifier_str_mv Akle, B. J. (2005). Characterization and modeling of the ionomer-conductor interface in ionic polymer transducers (Doctoral dissertation).
language_invalid_str_mv en
network_acronym_str LAURepo
network_name_str Lebanese American University repository
oai_identifier_str oai:laur.lau.edu.lb:10725/6934
publishDate 2005
publisher.none.fl_str_mv Virginia Polytechnic Institute and State University
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Characterization and modeling of the ionomer-conductor interface in ionic polymerAkle, Barbar J.Ionomeric polymer transducers consist of an ion-exchange membrane plated with conductive metal layers on its outer surfaces. Such materials are known to exhibit electromechanical coupling under the application of electric fields and imposed deformation (Oguro et al., 1992; Shahinpoor et al., 1998). Compared to other types of electromechanical transducers, such as piezoelectric materials, ionomeric transducers have the advantage of high-strain output (> 9% is possible), low-voltage operation (typically less than 5 V), and high sensitivity in the charge-sensing mode. A series of experiments on actuators with various ionic polymers such as Nafion and novel poly(Arylene ether disulphonate) systems (BPS and PATS) and electrode composition demonstrated the existence of a linear correlation between the strain response and the capacitance of the material. This correlation was shown to be independent of the polymer composition and the plating parameters. Due to the fact that the low-frequency capacitance of an ionomer is strongly related to charge accumulation at the electrodes, this correlation suggests a strong relationship between the surface charge accumulation and the mechanical deformation in ionomeric actuators. The strain response of water-hydrated transducers varies from 50 μstrain/V to 750 μstrain/V at 1Hz while the strain-to-charge response is between 9 μstrain and 15 μstrain. This contribution suggests a strong correlation between cationic motion and the strain in the polymer at the ionomer-conductor interface. A novel fabrication technique for ionic polymer transducers was developed for this dissertation for the purpose of quantifying the relationship between electrode composition and transducer performance. It consists of mixing an ionic polymer dispersion (or solution) with a fine conducting powder and attaching it to the membrane as an electrode. The Direct Assembly Process (DAP) allows the use of any type of ionomer, diluent, conducting powder, and counter ion in the transducer, and permits the exploration of any novel polymeric design. Several conducting powders have been incorporated in the electrode including single-walled carbon nanotubes (SWNT), polyaniline (PANI) powders, high surface area RuO2, and carbon black electrodes. The DAP provided the tool which enabled us to study the effect of electrode architecture on performance of ionic polymer transducers. The DAP allows the variation in the electrode architecture which enabled us to fabricate dry transducers with 50x better performance compared to transducers made using the state of the art impregnation-reduction technique. DAP fabricated transducers achieved a strain of 9.4% at a strain rate of 1%/s. Each electrode material had an optimal concentration in the electrode. For RuO2, the optimal loading was approximately 45% by volume. This study also demonstrated that carbon nanotubes electrodes have an optimal performance at loadings around 30 vol%, while PANI electrodes are optimized at 95 vol%. Extensional actuation in ionic polymer transducers was first reported and characterized in this dissertation. An electromechanical coupling model presented by Leo et al. (2005) defined the strain in the active areas as a function of the charge. This model assumed a linear and a quadratic term that produces a nonlinear response for a sine wave actuation input. The quadratic term in the strain generates a zero net bending moment for ionic polymer transducers with symmetric electrodes, while the linear term is canceled in extensional actuation for symmetric electrodes. Experimental results demonstrated strains on the order of 110 μstrain in the thickness direction compared to 1700 μstrain peak to peak on the external fibers for the same transducer, could be achieved when it is allowed to bend under +/-2V potential at 0.5 Hz. Extensional and bending actuation in ionic polymer transducers were explained using a bimorph active area model. Several experiments were performed to compare the bending actuation with the extensional actuation capability. The active area in the model was assumed to be the high surface area electrode. Electric double layer theory states that ions accumulate in a thin boundary layer close to the metal-polymer interface. Since the metal powders are evenly dispersed in the electrode area of the transducer, this area is expected to actuate evenly upon voltage application. This active area model emphasizes the importance the boundary layer on the conductor-ionomer interfacial area. Computing model parameters based on experimental results demonstrated that the active areas model collapses the bending data from a maximum variation of 200% for the strain per charge, to less than 68% for the model linear term. Furthermore, the model successfully predicted bending response from parameters computed using thickness experimental results. The prediction was particularly precise in estimating the trends of non-linearity as a function of the amount of asymmetry between the two electrodes.N/Axviii, 130 p illVirginia Polytechnic Institute and State University2018-01-22T14:34:01Z2018-01-22T14:34:01Z20052018-01-22Thesisinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10725/6934Akle, B. J. (2005). Characterization and modeling of the ionomer-conductor interface in ionic polymer transducers (Doctoral dissertation).http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.phphttps://vtechworks.lib.vt.edu/bitstream/handle/10919/28682/Barbar_Akle_Dissertation_2005.pdf?sequence=1&isAllowed=yeninfo:eu-repo/semantics/openAccessoai:laur.lau.edu.lb:10725/69342021-03-19T10:43:19Z
spellingShingle Characterization and modeling of the ionomer-conductor interface in ionic polymer
Akle, Barbar J.
status_str publishedVersion
title Characterization and modeling of the ionomer-conductor interface in ionic polymer
title_full Characterization and modeling of the ionomer-conductor interface in ionic polymer
title_fullStr Characterization and modeling of the ionomer-conductor interface in ionic polymer
title_full_unstemmed Characterization and modeling of the ionomer-conductor interface in ionic polymer
title_short Characterization and modeling of the ionomer-conductor interface in ionic polymer
title_sort Characterization and modeling of the ionomer-conductor interface in ionic polymer
url http://hdl.handle.net/10725/6934
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php
https://vtechworks.lib.vt.edu/bitstream/handle/10919/28682/Barbar_Akle_Dissertation_2005.pdf?sequence=1&isAllowed=y