The effects of needleless connectors on catheter-related bloodstream infections

Needleless connectors, including the standard split septum and the luer-activated mechanical valve connectors, have been introduced into clinical practice to eliminate the risk of needlestick injuries by avoiding the use of needles when accessing the intravascular catheters. Negative and positive di...

Full description

Saved in:
Bibliographic Details
Main Author: Btaiche, Imad F. (author)
Other Authors: Kovacevich, Debra S. (author), Khalidi, Nabil (author), Papke, Lorelei F. (author)
Format: article
Published: 2011
Online Access:http://hdl.handle.net/10725/4524
http://dx.doi.org/10.1016/j.ajic.2010.07.011
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php
http://www.sciencedirect.com/science/article/pii/S0196655310008953
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1864513463950245888
author Btaiche, Imad F.
author2 Kovacevich, Debra S.
Khalidi, Nabil
Papke, Lorelei F.
author2_role author
author
author
author_facet Btaiche, Imad F.
Kovacevich, Debra S.
Khalidi, Nabil
Papke, Lorelei F.
author_role author
dc.creator.none.fl_str_mv Btaiche, Imad F.
Kovacevich, Debra S.
Khalidi, Nabil
Papke, Lorelei F.
dc.date.none.fl_str_mv 2011
2016-10-06T12:12:03Z
2016-10-06T12:12:03Z
2016-10-06
dc.identifier.none.fl_str_mv 0196-6553
http://hdl.handle.net/10725/4524
http://dx.doi.org/10.1016/j.ajic.2010.07.011
Btaiche, I. F., Kovacevich, D. S., Khalidi, N., & Papke, L. F. (2011). The effects of needleless connectors on catheter-related bloodstream infections. American journal of infection control, 39(4), 277-283.
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php
http://www.sciencedirect.com/science/article/pii/S0196655310008953
dc.language.none.fl_str_mv en
dc.relation.none.fl_str_mv American Journal of Infection Control
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.title.none.fl_str_mv The effects of needleless connectors on catheter-related bloodstream infections
dc.type.none.fl_str_mv Article
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Needleless connectors, including the standard split septum and the luer-activated mechanical valve connectors, have been introduced into clinical practice to eliminate the risk of needlestick injuries by avoiding the use of needles when accessing the intravascular catheters. Negative and positive displacement mechanical valves have been associated with increased rates of catheter-related bloodstream infections as compared with split septum connectors. Based on available data, split septum connectors should be preferentially used instead of mechanical valves. Adequate disinfection by scrubbing the access port preferably with chlorhexidine is recommended to minimize the risk of catheter microbial contamination along with proper infection control practices. Large prospective randomized clinical trials are needed to evaluate further the possible causes and effects of different types of mechanical valve needleless connectors on bloodstream infections.
eu_rights_str_mv openAccess
format article
id LAURepo_ea60ee43e95f7de59ddcfffe648a68f6
identifier_str_mv 0196-6553
Btaiche, I. F., Kovacevich, D. S., Khalidi, N., & Papke, L. F. (2011). The effects of needleless connectors on catheter-related bloodstream infections. American journal of infection control, 39(4), 277-283.
language_invalid_str_mv en
network_acronym_str LAURepo
network_name_str Lebanese American University repository
oai_identifier_str oai:laur.lau.edu.lb:10725/4524
publishDate 2011
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling The effects of needleless connectors on catheter-related bloodstream infectionsBtaiche, Imad F.Kovacevich, Debra S.Khalidi, NabilPapke, Lorelei F.Needleless connectors, including the standard split septum and the luer-activated mechanical valve connectors, have been introduced into clinical practice to eliminate the risk of needlestick injuries by avoiding the use of needles when accessing the intravascular catheters. Negative and positive displacement mechanical valves have been associated with increased rates of catheter-related bloodstream infections as compared with split septum connectors. Based on available data, split septum connectors should be preferentially used instead of mechanical valves. Adequate disinfection by scrubbing the access port preferably with chlorhexidine is recommended to minimize the risk of catheter microbial contamination along with proper infection control practices. Large prospective randomized clinical trials are needed to evaluate further the possible causes and effects of different types of mechanical valve needleless connectors on bloodstream infections.PublishedN/A2016-10-06T12:12:03Z2016-10-06T12:12:03Z20112016-10-06Articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article0196-6553http://hdl.handle.net/10725/4524http://dx.doi.org/10.1016/j.ajic.2010.07.011Btaiche, I. F., Kovacevich, D. S., Khalidi, N., & Papke, L. F. (2011). The effects of needleless connectors on catheter-related bloodstream infections. American journal of infection control, 39(4), 277-283.http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.phphttp://www.sciencedirect.com/science/article/pii/S0196655310008953enAmerican Journal of Infection Controlinfo:eu-repo/semantics/openAccessoai:laur.lau.edu.lb:10725/45242021-03-19T10:03:23Z
spellingShingle The effects of needleless connectors on catheter-related bloodstream infections
Btaiche, Imad F.
status_str publishedVersion
title The effects of needleless connectors on catheter-related bloodstream infections
title_full The effects of needleless connectors on catheter-related bloodstream infections
title_fullStr The effects of needleless connectors on catheter-related bloodstream infections
title_full_unstemmed The effects of needleless connectors on catheter-related bloodstream infections
title_short The effects of needleless connectors on catheter-related bloodstream infections
title_sort The effects of needleless connectors on catheter-related bloodstream infections
url http://hdl.handle.net/10725/4524
http://dx.doi.org/10.1016/j.ajic.2010.07.011
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php
http://www.sciencedirect.com/science/article/pii/S0196655310008953