Successful use of MiniMed 780G during pregnancy
<h3>Background</h3><p dir="ltr">Pregnancy in the setting of type 1 diabetes (T1D) is associated with increased morbidity and mortality. There is strong evidence to suggest that the use of continuous glucose monitoring (CGM) is associated with better glycemic control and r...
محفوظ في:
| المؤلف الرئيسي: | |
|---|---|
| مؤلفون آخرون: | , , , , , , |
| منشور في: |
2023
|
| الموضوعات: | |
| الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
| _version_ | 1864513560091033600 |
|---|---|
| author | Khaled Ahmed Baagar (17032266) |
| author2 | Hamda Ali (14115357) Dabia Al-Mohanadi (17032269) Kawsar Mohamed Mohamud (17032272) Najlaa Sultan Alnaimi (17032275) Naglaa Alsharkawy (17032278) Eman Mahmoud Othman (17032281) Mohammed Bashir (5593550) |
| author2_role | author author author author author author author |
| author_facet | Khaled Ahmed Baagar (17032266) Hamda Ali (14115357) Dabia Al-Mohanadi (17032269) Kawsar Mohamed Mohamud (17032272) Najlaa Sultan Alnaimi (17032275) Naglaa Alsharkawy (17032278) Eman Mahmoud Othman (17032281) Mohammed Bashir (5593550) |
| author_role | author |
| dc.creator.none.fl_str_mv | Khaled Ahmed Baagar (17032266) Hamda Ali (14115357) Dabia Al-Mohanadi (17032269) Kawsar Mohamed Mohamud (17032272) Najlaa Sultan Alnaimi (17032275) Naglaa Alsharkawy (17032278) Eman Mahmoud Othman (17032281) Mohammed Bashir (5593550) |
| dc.date.none.fl_str_mv | 2023-12-01T00:00:00Z |
| dc.identifier.none.fl_str_mv | 10.1016/j.jecr.2023.100156 |
| dc.relation.none.fl_str_mv | https://figshare.com/articles/journal_contribution/Successful_use_of_MiniMed_780G_during_pregnancy/24188289 |
| dc.rights.none.fl_str_mv | CC BY 4.0 info:eu-repo/semantics/openAccess |
| dc.subject.none.fl_str_mv | Biomedical and clinical sciences Clinical sciences Reproductive medicine Pregnancy Type 1 diabetes Hybrid closed-loop Automated insulin delivery MiniMed 780G Insulin pump |
| dc.title.none.fl_str_mv | Successful use of MiniMed 780G during pregnancy |
| dc.type.none.fl_str_mv | Text Journal contribution info:eu-repo/semantics/publishedVersion text contribution to journal |
| description | <h3>Background</h3><p dir="ltr">Pregnancy in the setting of type 1 diabetes (T1D) is associated with increased morbidity and mortality. There is strong evidence to suggest that the use of continuous glucose monitoring (CGM) is associated with better glycemic control and reduced adverse pregnancy outcomes. As hybrid closed-loop (HCL) systems are increasingly used among women with T1D, many prefer to continue off-label use of these systems during pregnancy. However, most of the available HCL systems’ glucose targets and algorithms are not designed to overcome the challenges that face insulin therapy during pregnancy. We are reporting on two females with T1D who used MiniMed 780G, an advanced HCL system, during their pregnancy with good outcomes.</p><h3>Cases presentation</h3><p dir="ltr">Case 1: A 23-year-old woman with T1D presented at 6 weeks gestation. She used MiniMed 780G before pregnancy and throughout her pregnancy. By assisting her HCL system with some techniques, such as earlier bolusing before meals and the use of fake carbs to correct high glucose, and providing frequent follow-up, she achieved pregnancy-specific HbA1C and CGM glycemic targets and had good perinatal outcomes. Case 2: A 26-year-old female with T1D presented at 10 weeks gestation. She had been using MiniMed 670G since before pregnancy, thereafter, she was shifted to MiniMed 780G at 23 weeks gestation. We offered her the same techniques to support her HCL, and she achieved pregnancy-specific time in range (psTIR) in the 3rd trimester with good perinatal outcomes.</p><h3>Conclusion</h3><p dir="ltr">We could achieve most of the pregnancy-specific glycemic targets with good maternal, fetal, and neonatal outcomes using MiniMed 780G, assisted with some techniques to increase the efficiency of insulin therapy during pregnancy.</p><h2>Other Information</h2><p dir="ltr">Published in: Journal of Clinical and Translational Endocrinology: Case Reports<br>License: <a href="http://creativecommons.org/licenses/by/4.0/" target="_blank">http://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1016/j.jecr.2023.100156" target="_blank">https://dx.doi.org/10.1016/j.jecr.2023.100156</a></p> |
| eu_rights_str_mv | openAccess |
| id | Manara2_117c37d29077ea13a418b972c6aeab6e |
| identifier_str_mv | 10.1016/j.jecr.2023.100156 |
| network_acronym_str | Manara2 |
| network_name_str | Manara2 |
| oai_identifier_str | oai:figshare.com:article/24188289 |
| publishDate | 2023 |
| repository.mail.fl_str_mv | |
| repository.name.fl_str_mv | |
| repository_id_str | |
| rights_invalid_str_mv | CC BY 4.0 |
| spelling | Successful use of MiniMed 780G during pregnancyKhaled Ahmed Baagar (17032266)Hamda Ali (14115357)Dabia Al-Mohanadi (17032269)Kawsar Mohamed Mohamud (17032272)Najlaa Sultan Alnaimi (17032275)Naglaa Alsharkawy (17032278)Eman Mahmoud Othman (17032281)Mohammed Bashir (5593550)Biomedical and clinical sciencesClinical sciencesReproductive medicinePregnancyType 1 diabetesHybrid closed-loopAutomated insulin deliveryMiniMed 780GInsulin pump<h3>Background</h3><p dir="ltr">Pregnancy in the setting of type 1 diabetes (T1D) is associated with increased morbidity and mortality. There is strong evidence to suggest that the use of continuous glucose monitoring (CGM) is associated with better glycemic control and reduced adverse pregnancy outcomes. As hybrid closed-loop (HCL) systems are increasingly used among women with T1D, many prefer to continue off-label use of these systems during pregnancy. However, most of the available HCL systems’ glucose targets and algorithms are not designed to overcome the challenges that face insulin therapy during pregnancy. We are reporting on two females with T1D who used MiniMed 780G, an advanced HCL system, during their pregnancy with good outcomes.</p><h3>Cases presentation</h3><p dir="ltr">Case 1: A 23-year-old woman with T1D presented at 6 weeks gestation. She used MiniMed 780G before pregnancy and throughout her pregnancy. By assisting her HCL system with some techniques, such as earlier bolusing before meals and the use of fake carbs to correct high glucose, and providing frequent follow-up, she achieved pregnancy-specific HbA1C and CGM glycemic targets and had good perinatal outcomes. Case 2: A 26-year-old female with T1D presented at 10 weeks gestation. She had been using MiniMed 670G since before pregnancy, thereafter, she was shifted to MiniMed 780G at 23 weeks gestation. We offered her the same techniques to support her HCL, and she achieved pregnancy-specific time in range (psTIR) in the 3rd trimester with good perinatal outcomes.</p><h3>Conclusion</h3><p dir="ltr">We could achieve most of the pregnancy-specific glycemic targets with good maternal, fetal, and neonatal outcomes using MiniMed 780G, assisted with some techniques to increase the efficiency of insulin therapy during pregnancy.</p><h2>Other Information</h2><p dir="ltr">Published in: Journal of Clinical and Translational Endocrinology: Case Reports<br>License: <a href="http://creativecommons.org/licenses/by/4.0/" target="_blank">http://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1016/j.jecr.2023.100156" target="_blank">https://dx.doi.org/10.1016/j.jecr.2023.100156</a></p>2023-12-01T00:00:00ZTextJournal contributioninfo:eu-repo/semantics/publishedVersiontextcontribution to journal10.1016/j.jecr.2023.100156https://figshare.com/articles/journal_contribution/Successful_use_of_MiniMed_780G_during_pregnancy/24188289CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/241882892023-12-01T00:00:00Z |
| spellingShingle | Successful use of MiniMed 780G during pregnancy Khaled Ahmed Baagar (17032266) Biomedical and clinical sciences Clinical sciences Reproductive medicine Pregnancy Type 1 diabetes Hybrid closed-loop Automated insulin delivery MiniMed 780G Insulin pump |
| status_str | publishedVersion |
| title | Successful use of MiniMed 780G during pregnancy |
| title_full | Successful use of MiniMed 780G during pregnancy |
| title_fullStr | Successful use of MiniMed 780G during pregnancy |
| title_full_unstemmed | Successful use of MiniMed 780G during pregnancy |
| title_short | Successful use of MiniMed 780G during pregnancy |
| title_sort | Successful use of MiniMed 780G during pregnancy |
| topic | Biomedical and clinical sciences Clinical sciences Reproductive medicine Pregnancy Type 1 diabetes Hybrid closed-loop Automated insulin delivery MiniMed 780G Insulin pump |