Robotic Aortic Annular Enlargement With Y-Incision and Rectangular Patch

<p dir="ltr">Surgical enlargement of the aortic annulus enables insertion of a larger prosthetic valve, avoiding patient–prosthesis mismatch (PPM). Although several aortic annular enlargement techniques have been described, the rectangular patch technique with an inverted Y-incision...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Ahsan Ehtesham (17316907) (author)
مؤلفون آخرون: Jai Parkash (380693) (author), Muhammad Zain Shaikh (22996354) (author), Korey Zellner (22996357) (author), Ghulam Murtaza (2559319) (author)
منشور في: 2025
الموضوعات:
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513524573667328
author Ahsan Ehtesham (17316907)
author2 Jai Parkash (380693)
Muhammad Zain Shaikh (22996354)
Korey Zellner (22996357)
Ghulam Murtaza (2559319)
author2_role author
author
author
author
author_facet Ahsan Ehtesham (17316907)
Jai Parkash (380693)
Muhammad Zain Shaikh (22996354)
Korey Zellner (22996357)
Ghulam Murtaza (2559319)
author_role author
dc.creator.none.fl_str_mv Ahsan Ehtesham (17316907)
Jai Parkash (380693)
Muhammad Zain Shaikh (22996354)
Korey Zellner (22996357)
Ghulam Murtaza (2559319)
dc.date.none.fl_str_mv 2025-09-16T09:00:00Z
dc.identifier.none.fl_str_mv 10.1177/15569845251375582
dc.relation.none.fl_str_mv https://figshare.com/articles/journal_contribution/Robotic_Aortic_Annular_Enlargement_With_Y-Incision_and_Rectangular_Patch/31056229
dc.rights.none.fl_str_mv CC BY 4.0
info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Biomedical and clinical sciences
Cardiovascular medicine and haematology
Engineering
Biomedical engineering
Cardiothoracic Surgery
Cardiac Valve Surgery
Robotic-Assisted Surgery
Prosthetic Heart Valves
Aortic Annulus
dc.title.none.fl_str_mv Robotic Aortic Annular Enlargement With Y-Incision and Rectangular Patch
dc.type.none.fl_str_mv Text
Journal contribution
info:eu-repo/semantics/publishedVersion
text
contribution to journal
description <p dir="ltr">Surgical enlargement of the aortic annulus enables insertion of a larger prosthetic valve, avoiding patient–prosthesis mismatch (PPM). Although several aortic annular enlargement techniques have been described, the rectangular patch technique with an inverted Y-incision along the left and noncoronary cusps is relatively recent. These procedures are technically challenging via minimally invasive approaches, but robotic assistance makes them possible.</p><p dir="ltr">The patient had symptomatic severe aortic valve stenosis with evidence of left ventricular dysfunction (ejection fraction = 45%, peak gradient = 47.2 mm Hg, mean gradient = 29.3 mm Hg, and aortic valve area = 0.6 cm<sup>2</sup>). Preoperative computed tomography measured the aortic annulus at 18 mm (patient body surface area = 1.9). Notably, moderate aortic stenosis was documented 6 months earlier with preserved ejection fraction (55% to 65%), indicating rapid disease progression.</p><h2 dir="ltr">Other Information</h2><p dir="ltr">Published in: Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery<br>License: <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank">https://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1177/15569845251375582" target="_blank">https://dx.doi.org/10.1177/15569845251375582</a></p>
eu_rights_str_mv openAccess
id Manara2_18e4a7d48e1fbee00f5585d97f14daa5
identifier_str_mv 10.1177/15569845251375582
network_acronym_str Manara2
network_name_str Manara2
oai_identifier_str oai:figshare.com:article/31056229
publishDate 2025
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv CC BY 4.0
spelling Robotic Aortic Annular Enlargement With Y-Incision and Rectangular PatchAhsan Ehtesham (17316907)Jai Parkash (380693)Muhammad Zain Shaikh (22996354)Korey Zellner (22996357)Ghulam Murtaza (2559319)Biomedical and clinical sciencesCardiovascular medicine and haematologyEngineeringBiomedical engineeringCardiothoracic SurgeryCardiac Valve SurgeryRobotic-Assisted SurgeryProsthetic Heart ValvesAortic Annulus<p dir="ltr">Surgical enlargement of the aortic annulus enables insertion of a larger prosthetic valve, avoiding patient–prosthesis mismatch (PPM). Although several aortic annular enlargement techniques have been described, the rectangular patch technique with an inverted Y-incision along the left and noncoronary cusps is relatively recent. These procedures are technically challenging via minimally invasive approaches, but robotic assistance makes them possible.</p><p dir="ltr">The patient had symptomatic severe aortic valve stenosis with evidence of left ventricular dysfunction (ejection fraction = 45%, peak gradient = 47.2 mm Hg, mean gradient = 29.3 mm Hg, and aortic valve area = 0.6 cm<sup>2</sup>). Preoperative computed tomography measured the aortic annulus at 18 mm (patient body surface area = 1.9). Notably, moderate aortic stenosis was documented 6 months earlier with preserved ejection fraction (55% to 65%), indicating rapid disease progression.</p><h2 dir="ltr">Other Information</h2><p dir="ltr">Published in: Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery<br>License: <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank">https://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1177/15569845251375582" target="_blank">https://dx.doi.org/10.1177/15569845251375582</a></p>2025-09-16T09:00:00ZTextJournal contributioninfo:eu-repo/semantics/publishedVersiontextcontribution to journal10.1177/15569845251375582https://figshare.com/articles/journal_contribution/Robotic_Aortic_Annular_Enlargement_With_Y-Incision_and_Rectangular_Patch/31056229CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/310562292025-09-16T09:00:00Z
spellingShingle Robotic Aortic Annular Enlargement With Y-Incision and Rectangular Patch
Ahsan Ehtesham (17316907)
Biomedical and clinical sciences
Cardiovascular medicine and haematology
Engineering
Biomedical engineering
Cardiothoracic Surgery
Cardiac Valve Surgery
Robotic-Assisted Surgery
Prosthetic Heart Valves
Aortic Annulus
status_str publishedVersion
title Robotic Aortic Annular Enlargement With Y-Incision and Rectangular Patch
title_full Robotic Aortic Annular Enlargement With Y-Incision and Rectangular Patch
title_fullStr Robotic Aortic Annular Enlargement With Y-Incision and Rectangular Patch
title_full_unstemmed Robotic Aortic Annular Enlargement With Y-Incision and Rectangular Patch
title_short Robotic Aortic Annular Enlargement With Y-Incision and Rectangular Patch
title_sort Robotic Aortic Annular Enlargement With Y-Incision and Rectangular Patch
topic Biomedical and clinical sciences
Cardiovascular medicine and haematology
Engineering
Biomedical engineering
Cardiothoracic Surgery
Cardiac Valve Surgery
Robotic-Assisted Surgery
Prosthetic Heart Valves
Aortic Annulus