Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes

<h3>Background</h3><p dir="ltr">Implantable cardioverter defibrillators (ICD) are battery‐operated devices used to manage irregular heart rhythms and deliver therapeutic shocks to the heart. This updated systematic review and meta‐analysis compares the efficacy and extrac...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Muhammad Fawad Tahir (22073279) (author)
مؤلفون آخرون: Adeena Maryyum (22330483) (author), Zainab Mubbashir (22330486) (author), Abdul Moiz Khan (22330489) (author), Syed Irtiza Imam (22330492) (author), Fatima Mustafa (9773756) (author), Syeda Zahra Hasan (22330495) (author), Umer Shoaib (22330498) (author), Areej Iqbal (22330501) (author), Osama Saeed (22330504) (author), Manisha Purushotham (22330507) (author), Maimoona Khan (22330510) (author), Shahtaj Tariq (22330513) (author), Muhammad Omar Larik (20365932) (author), Muhammad Umair Anjum (21296653) (author), Muhammad Hasanain (14055585) (author), Tanesh Ayyalu (22073309) (author), Mah I. Kan Changez (20542744) (author), Javed Iqbal (2121922) (author)
منشور في: 2025
الموضوعات:
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513538092957696
author Muhammad Fawad Tahir (22073279)
author2 Adeena Maryyum (22330483)
Zainab Mubbashir (22330486)
Abdul Moiz Khan (22330489)
Syed Irtiza Imam (22330492)
Fatima Mustafa (9773756)
Syeda Zahra Hasan (22330495)
Umer Shoaib (22330498)
Areej Iqbal (22330501)
Osama Saeed (22330504)
Manisha Purushotham (22330507)
Maimoona Khan (22330510)
Shahtaj Tariq (22330513)
Muhammad Omar Larik (20365932)
Muhammad Umair Anjum (21296653)
Muhammad Hasanain (14055585)
Tanesh Ayyalu (22073309)
Mah I. Kan Changez (20542744)
Javed Iqbal (2121922)
author2_role author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author_facet Muhammad Fawad Tahir (22073279)
Adeena Maryyum (22330483)
Zainab Mubbashir (22330486)
Abdul Moiz Khan (22330489)
Syed Irtiza Imam (22330492)
Fatima Mustafa (9773756)
Syeda Zahra Hasan (22330495)
Umer Shoaib (22330498)
Areej Iqbal (22330501)
Osama Saeed (22330504)
Manisha Purushotham (22330507)
Maimoona Khan (22330510)
Shahtaj Tariq (22330513)
Muhammad Omar Larik (20365932)
Muhammad Umair Anjum (21296653)
Muhammad Hasanain (14055585)
Tanesh Ayyalu (22073309)
Mah I. Kan Changez (20542744)
Javed Iqbal (2121922)
author_role author
dc.creator.none.fl_str_mv Muhammad Fawad Tahir (22073279)
Adeena Maryyum (22330483)
Zainab Mubbashir (22330486)
Abdul Moiz Khan (22330489)
Syed Irtiza Imam (22330492)
Fatima Mustafa (9773756)
Syeda Zahra Hasan (22330495)
Umer Shoaib (22330498)
Areej Iqbal (22330501)
Osama Saeed (22330504)
Manisha Purushotham (22330507)
Maimoona Khan (22330510)
Shahtaj Tariq (22330513)
Muhammad Omar Larik (20365932)
Muhammad Umair Anjum (21296653)
Muhammad Hasanain (14055585)
Tanesh Ayyalu (22073309)
Mah I. Kan Changez (20542744)
Javed Iqbal (2121922)
dc.date.none.fl_str_mv 2025-02-05T03:00:00Z
dc.identifier.none.fl_str_mv 10.1002/clc.70083
dc.relation.none.fl_str_mv https://figshare.com/articles/journal_contribution/Comparison_of_Single_Coil_Versus_Dual_Coil_Implantable_Cardioverter_Defibrillator_Devices_A_Systematic_Review_and_Meta_Analysis_of_Efficacy_and_Extraction_Related_Outcomes/30233980
dc.rights.none.fl_str_mv CC BY 4.0
info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Biomedical and clinical sciences
Cardiovascular medicine and haematology
dual‐coil
ICD
implantable cardioverter defibrillators
lead extraction
single‐coil
dc.title.none.fl_str_mv Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes
dc.type.none.fl_str_mv Text
Journal contribution
info:eu-repo/semantics/publishedVersion
text
contribution to journal
description <h3>Background</h3><p dir="ltr">Implantable cardioverter defibrillators (ICD) are battery‐operated devices used to manage irregular heart rhythms and deliver therapeutic shocks to the heart. This updated systematic review and meta‐analysis compares the efficacy and extraction‐related outcomes of single‐coil versus dual‐coil ICDs in view of conflicting data.</p><h3>Methods</h3><p dir="ltr">Several databases, including PubMed, Cochrane Library, and Google Scholar, were comprehensively explored dating from inception to April 1, 2024. Data were compared using odds ratio (OR), hazard ratio (HR), and mean differences (MD). A value of <i>p</i> < 0.05 indicated statistical significance.</p><h3>Results</h3><p dir="ltr">Ultimately, 28 studies were included in this quantitative synthesis. Defibrillation threshold (DFT) indicated statistical superiority in the dual‐coil cohort (MD: 0.58; 95% confidence interval [CI]: 0.07–1.09; <i>p</i> = 0.03). In addition, all‐cause mortality was significantly elevated in the dual‐coil cohort (HR: 0.91; 95% CI: 0.87–0.97; <i>p</i> = 0.001). Furthermore, implant time was significantly lower in the single‐coil group (MD: −7.44; 95% CI: −13.44 to −1.43; <i>p</i> = 0.02). Other outcomes, including first shock efficacy, cardiac mortality, post‐extraction major complications, post‐extraction procedural success, and post‐extraction mortality, did not demonstrate any significant statistical differences.</p><h3>Conclusion</h3><p dir="ltr">In conclusion, despite the desirable safety profile of single‐coil ICDs, the use of dual‐coil ICDs continues to hold merit due to their superior efficacy and advanced sensing capabilities, especially in complex cases. In addition, the perceived risk of a greater adverse profile in dual‐coil lead extraction can be refuted by preliminary aggregate results generated within this meta‐analysis. However, further robust studies are warranted before arriving at a valid conclusion.</p><h2>Other Information</h2><p dir="ltr">Published in: Clinical Cardiology<br>License: <a href="http://creativecommons.org/licenses/by/4.0/" target="_blank">http://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1002/clc.70083" target="_blank">https://dx.doi.org/10.1002/clc.70083</a></p>
eu_rights_str_mv openAccess
id Manara2_1c15c2e26df865662c0839be659bf116
identifier_str_mv 10.1002/clc.70083
network_acronym_str Manara2
network_name_str Manara2
oai_identifier_str oai:figshare.com:article/30233980
publishDate 2025
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv CC BY 4.0
spelling Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related OutcomesMuhammad Fawad Tahir (22073279)Adeena Maryyum (22330483)Zainab Mubbashir (22330486)Abdul Moiz Khan (22330489)Syed Irtiza Imam (22330492)Fatima Mustafa (9773756)Syeda Zahra Hasan (22330495)Umer Shoaib (22330498)Areej Iqbal (22330501)Osama Saeed (22330504)Manisha Purushotham (22330507)Maimoona Khan (22330510)Shahtaj Tariq (22330513)Muhammad Omar Larik (20365932)Muhammad Umair Anjum (21296653)Muhammad Hasanain (14055585)Tanesh Ayyalu (22073309)Mah I. Kan Changez (20542744)Javed Iqbal (2121922)Biomedical and clinical sciencesCardiovascular medicine and haematologydual‐coilICDimplantable cardioverter defibrillatorslead extractionsingle‐coil<h3>Background</h3><p dir="ltr">Implantable cardioverter defibrillators (ICD) are battery‐operated devices used to manage irregular heart rhythms and deliver therapeutic shocks to the heart. This updated systematic review and meta‐analysis compares the efficacy and extraction‐related outcomes of single‐coil versus dual‐coil ICDs in view of conflicting data.</p><h3>Methods</h3><p dir="ltr">Several databases, including PubMed, Cochrane Library, and Google Scholar, were comprehensively explored dating from inception to April 1, 2024. Data were compared using odds ratio (OR), hazard ratio (HR), and mean differences (MD). A value of <i>p</i> < 0.05 indicated statistical significance.</p><h3>Results</h3><p dir="ltr">Ultimately, 28 studies were included in this quantitative synthesis. Defibrillation threshold (DFT) indicated statistical superiority in the dual‐coil cohort (MD: 0.58; 95% confidence interval [CI]: 0.07–1.09; <i>p</i> = 0.03). In addition, all‐cause mortality was significantly elevated in the dual‐coil cohort (HR: 0.91; 95% CI: 0.87–0.97; <i>p</i> = 0.001). Furthermore, implant time was significantly lower in the single‐coil group (MD: −7.44; 95% CI: −13.44 to −1.43; <i>p</i> = 0.02). Other outcomes, including first shock efficacy, cardiac mortality, post‐extraction major complications, post‐extraction procedural success, and post‐extraction mortality, did not demonstrate any significant statistical differences.</p><h3>Conclusion</h3><p dir="ltr">In conclusion, despite the desirable safety profile of single‐coil ICDs, the use of dual‐coil ICDs continues to hold merit due to their superior efficacy and advanced sensing capabilities, especially in complex cases. In addition, the perceived risk of a greater adverse profile in dual‐coil lead extraction can be refuted by preliminary aggregate results generated within this meta‐analysis. However, further robust studies are warranted before arriving at a valid conclusion.</p><h2>Other Information</h2><p dir="ltr">Published in: Clinical Cardiology<br>License: <a href="http://creativecommons.org/licenses/by/4.0/" target="_blank">http://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1002/clc.70083" target="_blank">https://dx.doi.org/10.1002/clc.70083</a></p>2025-02-05T03:00:00ZTextJournal contributioninfo:eu-repo/semantics/publishedVersiontextcontribution to journal10.1002/clc.70083https://figshare.com/articles/journal_contribution/Comparison_of_Single_Coil_Versus_Dual_Coil_Implantable_Cardioverter_Defibrillator_Devices_A_Systematic_Review_and_Meta_Analysis_of_Efficacy_and_Extraction_Related_Outcomes/30233980CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/302339802025-02-05T03:00:00Z
spellingShingle Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes
Muhammad Fawad Tahir (22073279)
Biomedical and clinical sciences
Cardiovascular medicine and haematology
dual‐coil
ICD
implantable cardioverter defibrillators
lead extraction
single‐coil
status_str publishedVersion
title Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes
title_full Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes
title_fullStr Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes
title_full_unstemmed Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes
title_short Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes
title_sort Comparison of Single‐Coil Versus Dual‐Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta‐Analysis of Efficacy and Extraction‐Related Outcomes
topic Biomedical and clinical sciences
Cardiovascular medicine and haematology
dual‐coil
ICD
implantable cardioverter defibrillators
lead extraction
single‐coil