Overview and Partial Discharge Analysis of Power Transformers: A Literature Review

<p>The high voltage power transformer is the critical element of the power system, which requires continuous monitoring to prevent sudden catastrophic failures and to ensure an uninterrupted power supply. The most common failures in the transformer are due to partial discharge (PD) in electric...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Md Rashid Hussain (16870113) (author)
مؤلفون آخرون: Shady S. Refaat (16864269) (author), Haitham Abu-Rub (16855500) (author)
منشور في: 2021
الموضوعات:
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513560348983296
author Md Rashid Hussain (16870113)
author2 Shady S. Refaat (16864269)
Haitham Abu-Rub (16855500)
author2_role author
author
author_facet Md Rashid Hussain (16870113)
Shady S. Refaat (16864269)
Haitham Abu-Rub (16855500)
author_role author
dc.creator.none.fl_str_mv Md Rashid Hussain (16870113)
Shady S. Refaat (16864269)
Haitham Abu-Rub (16855500)
dc.date.none.fl_str_mv 2021-04-23T00:00:00Z
dc.identifier.none.fl_str_mv 10.1109/access.2021.3075288
dc.relation.none.fl_str_mv https://figshare.com/articles/journal_contribution/Overview_and_Partial_Discharge_Analysis_of_Power_Transformers_A_Literature_Review/24042483
dc.rights.none.fl_str_mv CC BY 4.0
info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Engineering
Electrical engineering
Partial discharges
Insulation
Power transformer insulation
Discharges (electric)
Circuit faults
Monitoring
Oil insulation
Power transformer
Partial discharge
Condition monitoring
Fault diagnosis
Feature extraction
dc.title.none.fl_str_mv Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
dc.type.none.fl_str_mv Text
Journal contribution
info:eu-repo/semantics/publishedVersion
text
contribution to journal
description <p>The high voltage power transformer is the critical element of the power system, which requires continuous monitoring to prevent sudden catastrophic failures and to ensure an uninterrupted power supply. The most common failures in the transformer are due to partial discharge (PD) in electrical insulations which are the results of the insulation degradation over time. Different approaches have been proposed to monitor, detect, and locate the partial discharge in power transformers. This paper reviews and evaluates the current state-of-the-art methods for PD detection and localization techniques, and methodologies in power transformers. Detailed comparisons of PD detection techniques have been identified and discussed in this paper. The drawbacks and challenges of different partial discharge measurement techniques have been elaborated. Finally, brief reviews of PD denoising signals, feature extraction of PD signals, and classification of partial discharge sources have been addressed.</p><h2>Other Information</h2><p>Published in: IEEE Access<br>License: <a href="https://creativecommons.org/licenses/by/4.0/legalcode" target="_blank">https://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1109/access.2021.3075288" target="_blank">https://dx.doi.org/10.1109/access.2021.3075288</a></p>
eu_rights_str_mv openAccess
id Manara2_66062ca461d7f8fec65909549d49f952
identifier_str_mv 10.1109/access.2021.3075288
network_acronym_str Manara2
network_name_str Manara2
oai_identifier_str oai:figshare.com:article/24042483
publishDate 2021
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv CC BY 4.0
spelling Overview and Partial Discharge Analysis of Power Transformers: A Literature ReviewMd Rashid Hussain (16870113)Shady S. Refaat (16864269)Haitham Abu-Rub (16855500)EngineeringElectrical engineeringPartial dischargesInsulationPower transformer insulationDischarges (electric)Circuit faultsMonitoringOil insulationPower transformerPartial dischargeCondition monitoringFault diagnosisFeature extraction<p>The high voltage power transformer is the critical element of the power system, which requires continuous monitoring to prevent sudden catastrophic failures and to ensure an uninterrupted power supply. The most common failures in the transformer are due to partial discharge (PD) in electrical insulations which are the results of the insulation degradation over time. Different approaches have been proposed to monitor, detect, and locate the partial discharge in power transformers. This paper reviews and evaluates the current state-of-the-art methods for PD detection and localization techniques, and methodologies in power transformers. Detailed comparisons of PD detection techniques have been identified and discussed in this paper. The drawbacks and challenges of different partial discharge measurement techniques have been elaborated. Finally, brief reviews of PD denoising signals, feature extraction of PD signals, and classification of partial discharge sources have been addressed.</p><h2>Other Information</h2><p>Published in: IEEE Access<br>License: <a href="https://creativecommons.org/licenses/by/4.0/legalcode" target="_blank">https://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1109/access.2021.3075288" target="_blank">https://dx.doi.org/10.1109/access.2021.3075288</a></p>2021-04-23T00:00:00ZTextJournal contributioninfo:eu-repo/semantics/publishedVersiontextcontribution to journal10.1109/access.2021.3075288https://figshare.com/articles/journal_contribution/Overview_and_Partial_Discharge_Analysis_of_Power_Transformers_A_Literature_Review/24042483CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/240424832021-04-23T00:00:00Z
spellingShingle Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
Md Rashid Hussain (16870113)
Engineering
Electrical engineering
Partial discharges
Insulation
Power transformer insulation
Discharges (electric)
Circuit faults
Monitoring
Oil insulation
Power transformer
Partial discharge
Condition monitoring
Fault diagnosis
Feature extraction
status_str publishedVersion
title Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
title_full Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
title_fullStr Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
title_full_unstemmed Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
title_short Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
title_sort Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
topic Engineering
Electrical engineering
Partial discharges
Insulation
Power transformer insulation
Discharges (electric)
Circuit faults
Monitoring
Oil insulation
Power transformer
Partial discharge
Condition monitoring
Fault diagnosis
Feature extraction