Opening the heart and absorbing the pain

<p>To treat patients suffering from atherosclerosis, heart surgeons may insert tiny tubes, or stents, into blocked blood vessels that feed the heart, providing support and allowing blood to flow freely. There are different kinds of stents in use, but some of the most recent developments are in...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Nature Research (16552612) (author)
منشور في: 2016
الموضوعات:
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513562330791936
author Nature Research (16552612)
author_facet Nature Research (16552612)
author_role author
dc.creator.none.fl_str_mv Nature Research (16552612)
dc.date.none.fl_str_mv 2016-06-30T00:00:00Z
dc.identifier.none.fl_str_mv 10.57945/manara.23951088.v1
dc.relation.none.fl_str_mv https://figshare.com/articles/online_resource/Opening_the_heart_and_absorbing_the_pain/23951088
dc.rights.none.fl_str_mv CC BY 4.0
info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Biomedical and clinical sciences
Cardiovascular medicine and haematology
Cardiology
atherosclerosis
Absorb BVS
bioabsorbable stents
dc.title.none.fl_str_mv Opening the heart and absorbing the pain
dc.type.none.fl_str_mv Text
Online resource
info:eu-repo/semantics/publishedVersion
text
description <p>To treat patients suffering from atherosclerosis, heart surgeons may insert tiny tubes, or stents, into blocked blood vessels that feed the heart, providing support and allowing blood to flow freely. There are different kinds of stents in use, but some of the most recent developments are in biodegradable stents, which are absorbed into the body after a certain period of time. Non-degradable metal stents carry a risk of forming blot clots in the vessels, which is deterred by coating them with a slowly released drug to prevent the recurrence of blockage.</p><p>Researchers in the United States reviewed three recent trials, which compared the safety and efficacy of the first-generation biodegradable stent, Absorb Bioresorbable Vascular Scaffold (Absorb BVS), with the latest drug-eluting stent, Xience.</p><p>A clinical trial conducted in the USA involved 2008 cardiac patients, one-third of whom were treated with Absorb BVS while the rest received Xience. Failure of the trial was defined as “target lesion failure”, leading to one or more of patient death, death of heart tissue served by the treated vessel, or revascularization of heart tissue served by the treated vessel because it was unable to supply it with enough blood.</p><p>The trial did not indicate that Absorb BVS was equal in performance to Xience. Rather, it showed that Absorb BVS was at least not worse; in other words it was “non-inferior” after one year of insertion. Target lesion failure occurred in 7.8% of Absorb BVS-treated patients compared to 6.1% in Xience patients. The team believes long-term evaluation of these patients will be important to determine whether Absorb BVS-treated patients fare well due to encouraging observations that this stent also helps blood vessels repair themselves.</p><p>Two other trials conducted in China and Japan, involving 480 and 400 cardiac patients respectively, measured blood vessel diameter after the procedure and then one year later. Both trials also indicated that Absorb BVS was non-inferior to Xience.</p><p>Notably, all three trials only involved blood vessel lesions of moderate complexity. More complex lesions were excluded.</p><p>The researchers, from Emory University School of Medicine in Atlanta, Georgia, USA, recommend in their paper published in the journal <i>Global Cardiology and Practice</i> that experienced cardiologists use bioabsorbable stents such as Absorb BVS only in selected lesions until future design improvements are made.</p><p>Critically, bioresorbable stents are twice the price of drug-eluting stents currently available on the market. This raises the obvious question about the merit of using the more expensive technology when there is no evident superiority over less costly devices, the researchers write.</p><p></p><h2>Other Information</h2><p>Published in: QScience.com Highlights, Published by Nature Research for Hamad bin Khalifa University Press (HBKU Press)<br>License: <a>http://creativecommons.org/licenses/by/4.0</a><br></p>
eu_rights_str_mv openAccess
id Manara2_697966b82bd85543b03ceb73fbb66db0
identifier_str_mv 10.57945/manara.23951088.v1
network_acronym_str Manara2
network_name_str Manara2
oai_identifier_str oai:figshare.com:article/23951088
publishDate 2016
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv CC BY 4.0
spelling Opening the heart and absorbing the painNature Research (16552612)Biomedical and clinical sciencesCardiovascular medicine and haematologyCardiologyatherosclerosisAbsorb BVSbioabsorbable stents<p>To treat patients suffering from atherosclerosis, heart surgeons may insert tiny tubes, or stents, into blocked blood vessels that feed the heart, providing support and allowing blood to flow freely. There are different kinds of stents in use, but some of the most recent developments are in biodegradable stents, which are absorbed into the body after a certain period of time. Non-degradable metal stents carry a risk of forming blot clots in the vessels, which is deterred by coating them with a slowly released drug to prevent the recurrence of blockage.</p><p>Researchers in the United States reviewed three recent trials, which compared the safety and efficacy of the first-generation biodegradable stent, Absorb Bioresorbable Vascular Scaffold (Absorb BVS), with the latest drug-eluting stent, Xience.</p><p>A clinical trial conducted in the USA involved 2008 cardiac patients, one-third of whom were treated with Absorb BVS while the rest received Xience. Failure of the trial was defined as “target lesion failure”, leading to one or more of patient death, death of heart tissue served by the treated vessel, or revascularization of heart tissue served by the treated vessel because it was unable to supply it with enough blood.</p><p>The trial did not indicate that Absorb BVS was equal in performance to Xience. Rather, it showed that Absorb BVS was at least not worse; in other words it was “non-inferior” after one year of insertion. Target lesion failure occurred in 7.8% of Absorb BVS-treated patients compared to 6.1% in Xience patients. The team believes long-term evaluation of these patients will be important to determine whether Absorb BVS-treated patients fare well due to encouraging observations that this stent also helps blood vessels repair themselves.</p><p>Two other trials conducted in China and Japan, involving 480 and 400 cardiac patients respectively, measured blood vessel diameter after the procedure and then one year later. Both trials also indicated that Absorb BVS was non-inferior to Xience.</p><p>Notably, all three trials only involved blood vessel lesions of moderate complexity. More complex lesions were excluded.</p><p>The researchers, from Emory University School of Medicine in Atlanta, Georgia, USA, recommend in their paper published in the journal <i>Global Cardiology and Practice</i> that experienced cardiologists use bioabsorbable stents such as Absorb BVS only in selected lesions until future design improvements are made.</p><p>Critically, bioresorbable stents are twice the price of drug-eluting stents currently available on the market. This raises the obvious question about the merit of using the more expensive technology when there is no evident superiority over less costly devices, the researchers write.</p><p></p><h2>Other Information</h2><p>Published in: QScience.com Highlights, Published by Nature Research for Hamad bin Khalifa University Press (HBKU Press)<br>License: <a>http://creativecommons.org/licenses/by/4.0</a><br></p>2016-06-30T00:00:00ZTextOnline resourceinfo:eu-repo/semantics/publishedVersiontext10.57945/manara.23951088.v1https://figshare.com/articles/online_resource/Opening_the_heart_and_absorbing_the_pain/23951088CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/239510882016-06-30T00:00:00Z
spellingShingle Opening the heart and absorbing the pain
Nature Research (16552612)
Biomedical and clinical sciences
Cardiovascular medicine and haematology
Cardiology
atherosclerosis
Absorb BVS
bioabsorbable stents
status_str publishedVersion
title Opening the heart and absorbing the pain
title_full Opening the heart and absorbing the pain
title_fullStr Opening the heart and absorbing the pain
title_full_unstemmed Opening the heart and absorbing the pain
title_short Opening the heart and absorbing the pain
title_sort Opening the heart and absorbing the pain
topic Biomedical and clinical sciences
Cardiovascular medicine and haematology
Cardiology
atherosclerosis
Absorb BVS
bioabsorbable stents