Eco-friendly paper-based colorimetric sensor for portable and rapid detection of lead (II) ions in aqueous environment

<p dir="ltr">Lead contamination in water bodies poses significant environmental and health risks, necessitating effective detection methods. This study presents a novel, cost-effective, and portable paper-based sensor for the visual detection of lead (II) ions in an aqueous medium us...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: N. M. Poovadichalil (22927906) (author)
مؤلفون آخرون: A. Ullah (7209965) (author), M. R. Maurya (22927909) (author), A. Hasan (5635746) (author), K. K. Sadasivuni (22927912) (author)
منشور في: 2025
الموضوعات:
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
الوصف
الملخص:<p dir="ltr">Lead contamination in water bodies poses significant environmental and health risks, necessitating effective detection methods. This study presents a novel, cost-effective, and portable paper-based sensor for the visual detection of lead (II) ions in an aqueous medium using the colorimetric dyes Eriochrome Black T and Bromothymol Blue. The sensor's sensitivity to varying concentrations of lead (II) ions is explored using UV–visible spectroscopy, with pH-adjusted dye solutions in acidic, neutral, and basic conditions. Both Eriochrome Black T and Bromothymol Blue dyes exhibited distinct colorimetric responses to the presence of lead (II), with optimal detection occurring in neutral pH environment. A concentration range of 60–140 ppm of lead (II) ions was examined, and the detection limits were lowest for Bromothymol Blue dye, found to be around 6 ppm. Furthermore, the selectivity of the dyes was tested against other metal ions, showing high specificity for lead (II) ions. The sensor's stability was verified across a temperature range of 25–90 °C. Finally, a paper-based chemo sensor was fabricated to demonstrate the sensor's real-time applicability, where visual color changes confirmed lead (II) detection in water. The developed sensor offers a promising alternative for field-based detection of lead in contaminated water sources, providing a low-cost, easy-to-use, and reliable method for environmental monitoring.</p><h2 dir="ltr">Other Information</h2><p dir="ltr">Published in: International Journal of Environmental Science and Technology<br>License: <a href="https://creativecommons.org/licenses/by/4.0" target="_blank">https://creativecommons.org/licenses/by/4.0</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1007/s13762-025-06636-6" target="_blank">https://dx.doi.org/10.1007/s13762-025-06636-6</a></p>