Neonatal Simulation Program: A 5 Years Educational Journey From Qatar
<p dir="ltr">We describe the process of implementation, adaptation, expansion and some related clinical intuitional impacts of the neonatal simulation program since its launch in 2016 in a non-simulation neonatal unit. The team has developed 6 types of curricula: 1 full-day course an...
Saved in:
| Main Author: | |
|---|---|
| Other Authors: | , , , , , , , , , , , , , |
| Published: |
2022
|
| Subjects: | |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | <p dir="ltr">We describe the process of implementation, adaptation, expansion and some related clinical intuitional impacts of the neonatal simulation program since its launch in 2016 in a non-simulation neonatal unit. The team has developed 6 types of curricula: 1 full-day course and 5 half-day workshops. A total of 35 free of charge simulation courses/workshops were conducted, 32 in Qatar and 3 abroad with a total of 799 diverse participants. There was a steady increase in the overall success rate of PICC insertion from 81.7% (309/378) to 97.6% (439/450) across 3 years (<i>P</i> < 0.0001). The first attempt PICC insertion success rate has been also increased from 57.7% (218/378) to 66.9% (301/450) across 3 years. The mean duration of PICC insertion has been improved from 39.7 ± 25 to 34.9 ± 12.4 min after implementing the program (<i>P</i> = 0.33). The mean duration of the LISA catheter insertion at the beginning of the workshop was 23.5 ± 15.9 compared to 12.1 ± 8.5 s at the end of the workshop (<i>P</i> = 0.001). When it came to clinical practise in real patients by the same participants, the overall LISA catheter insertion success rate was 100% and the first attempt success rate was 80.4%. The mean duration of LISA catheter insertion in real patients was 26.9 ± 13.9 s compared to the end of the workshop (<i>P</i> = 0.001). The mean duration of the endotracheal intubation at the beginning of the workshop was 12.5 ± 9.2 compared to 4.2 ± 3.8 s at the end of the workshop (<i>P</i> = 0.001). In real patients, the first-attempt intubation success rate has been improved from 37/139 (26.6%) in the first year to 141/187 (75.5%) in the second year after the program implementation (<i>P</i> = 0.001). The mean duration of successful endotracheal intubation attempts has been improved from 39.1 ± 52.4 to 20.1 ± 9.9 s (<i>P</i> = 0.78). As per the participants, the skills learned in the program sessions help in protecting neonates from potential harm and improve the overall neonatal outcome. Implementing a neonatal simulation program is a promising and feasible idea. Our experience can be generalised and replicated in other neonatal care institutions.</p><h2>Other Information</h2><p dir="ltr">Published in: Frontiers in Pediatrics<br>License: <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank">https://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.3389/fped.2022.843147" target="_blank">https://dx.doi.org/10.3389/fped.2022.843147</a></p> |
|---|