Simulating blood vessel scaffolds

<p dir="ltr">Computer simulations of how drug-releasing stents interact with flowing blood immediately following implantation may improve design of such devices, as well as help predict the outcomes of patients in whom they are implanted, according to a new study by researchers at Em...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Nature Research (16552612) (author)
منشور في: 2015
الموضوعات:
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513559528996864
author Nature Research (16552612)
author_facet Nature Research (16552612)
author_role author
dc.creator.none.fl_str_mv Nature Research (16552612)
dc.date.none.fl_str_mv 2015-03-30T00:00:00Z
dc.identifier.none.fl_str_mv 10.57945/manara.23909742.v1
dc.relation.none.fl_str_mv https://figshare.com/articles/online_resource/Simulating_blood_vessel_scaffolds/23909742
dc.rights.none.fl_str_mv CC BY 4.0
info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Biomedical and clinical sciences
Cardiovascular medicine and haematology
cardiology
heart disease
angioplasty
stents
bioresorption
dc.title.none.fl_str_mv Simulating blood vessel scaffolds
dc.type.none.fl_str_mv Text
Online resource
info:eu-repo/semantics/publishedVersion
text
description <p dir="ltr">Computer simulations of how drug-releasing stents interact with flowing blood immediately following implantation may improve design of such devices, as well as help predict the outcomes of patients in whom they are implanted, according to a new study by researchers at Emory University . Stents are usually made of metallic scaffolds, and are commonly implanted into heart disease patients, by a procedure called angioplasty, in order to widen narrowed arteries and alleviate symptoms such as chest pain. In recent years there have been a number of important innovations in stent design, including a reduction in the size of the devices, and the development of stents made of absorbent materials that can be coated with drugs. Nevertheless, implantation still carries risks, as it often causes inflammation. Stents also affect the function of blood vessels function by altering their diameter, and blood clots can sometimes form inside them following transplantation. Habib Samady and his colleagues used computational fluid dynamics to generate three-dimensional simulations of how drug-releasing bioresorbable scaffolds interact with vessels and affect blood flow. These devices are designed to release drugs slowly and then dissolve or be absorbed by the tissues surrounding them. The researchers simulated the effects of a stent positioned in various locations of straight and curved blood vessels, focusing on the amount of shear stress the device places on the walls of the vessels, and how this affects blood flow. According to their simulations, the amount of shear stress is highest at the endoluminal strut surface, where the stent comes into contact with the inner lining of the vessels, but very low at the areas where blood flows in and out of the device. At 33% bioresorption of the stent, the picture began to change. The model showed that the amount of stress at the endoluminal surface — where the stent comes into contact with the side of the vessel — is reduced by about one third, but increases by more than 100% at the in-flow and out-flow regions, leading to a more uniform distribution of stress across the device at this stage. The model also revealed that these effects were more pronounced at the inner than the outer curvatures of curved vessels.</p><p><br></p><h2>Other Information</h2><p dir="ltr">Published in: QScience.com Highlights, Published by Nature Research for Hamad bin Khalifa University Press (HBKU Press)<br>License: <a href="http://creativecommons.org/licenses/by/4.0" target="_blank">http://creativecommons.org/licenses/by/4.0</a><br></p>
eu_rights_str_mv openAccess
id Manara2_a61fd74ea1f26d09c25891f4266154b6
identifier_str_mv 10.57945/manara.23909742.v1
network_acronym_str Manara2
network_name_str Manara2
oai_identifier_str oai:figshare.com:article/23909742
publishDate 2015
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv CC BY 4.0
spelling Simulating blood vessel scaffoldsNature Research (16552612)Biomedical and clinical sciencesCardiovascular medicine and haematologycardiologyheart diseaseangioplastystentsbioresorption<p dir="ltr">Computer simulations of how drug-releasing stents interact with flowing blood immediately following implantation may improve design of such devices, as well as help predict the outcomes of patients in whom they are implanted, according to a new study by researchers at Emory University . Stents are usually made of metallic scaffolds, and are commonly implanted into heart disease patients, by a procedure called angioplasty, in order to widen narrowed arteries and alleviate symptoms such as chest pain. In recent years there have been a number of important innovations in stent design, including a reduction in the size of the devices, and the development of stents made of absorbent materials that can be coated with drugs. Nevertheless, implantation still carries risks, as it often causes inflammation. Stents also affect the function of blood vessels function by altering their diameter, and blood clots can sometimes form inside them following transplantation. Habib Samady and his colleagues used computational fluid dynamics to generate three-dimensional simulations of how drug-releasing bioresorbable scaffolds interact with vessels and affect blood flow. These devices are designed to release drugs slowly and then dissolve or be absorbed by the tissues surrounding them. The researchers simulated the effects of a stent positioned in various locations of straight and curved blood vessels, focusing on the amount of shear stress the device places on the walls of the vessels, and how this affects blood flow. According to their simulations, the amount of shear stress is highest at the endoluminal strut surface, where the stent comes into contact with the inner lining of the vessels, but very low at the areas where blood flows in and out of the device. At 33% bioresorption of the stent, the picture began to change. The model showed that the amount of stress at the endoluminal surface — where the stent comes into contact with the side of the vessel — is reduced by about one third, but increases by more than 100% at the in-flow and out-flow regions, leading to a more uniform distribution of stress across the device at this stage. The model also revealed that these effects were more pronounced at the inner than the outer curvatures of curved vessels.</p><p><br></p><h2>Other Information</h2><p dir="ltr">Published in: QScience.com Highlights, Published by Nature Research for Hamad bin Khalifa University Press (HBKU Press)<br>License: <a href="http://creativecommons.org/licenses/by/4.0" target="_blank">http://creativecommons.org/licenses/by/4.0</a><br></p>2015-03-30T00:00:00ZTextOnline resourceinfo:eu-repo/semantics/publishedVersiontext10.57945/manara.23909742.v1https://figshare.com/articles/online_resource/Simulating_blood_vessel_scaffolds/23909742CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/239097422015-03-30T00:00:00Z
spellingShingle Simulating blood vessel scaffolds
Nature Research (16552612)
Biomedical and clinical sciences
Cardiovascular medicine and haematology
cardiology
heart disease
angioplasty
stents
bioresorption
status_str publishedVersion
title Simulating blood vessel scaffolds
title_full Simulating blood vessel scaffolds
title_fullStr Simulating blood vessel scaffolds
title_full_unstemmed Simulating blood vessel scaffolds
title_short Simulating blood vessel scaffolds
title_sort Simulating blood vessel scaffolds
topic Biomedical and clinical sciences
Cardiovascular medicine and haematology
cardiology
heart disease
angioplasty
stents
bioresorption