Trueness and precision of facial scan and virtual patient representation workflow

<h3>Purpose</h3><p dir="ltr">To investigate the feasibility and accuracy (trueness and precision) of facial scanning and virtual patient representation (VPR).</p><h3>Materials and Methods</h3><p dir="ltr">One participant was recruited and...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Khaled Q. Al Hamad (21768251) (author)
مؤلفون آخرون: Jad Q. Ayyad (22330648) (author), Bashar A. Al‐Rashdan (22330651) (author), Firas A. Al Quran (22330654) (author)
منشور في: 2025
الموضوعات:
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513538058354688
author Khaled Q. Al Hamad (21768251)
author2 Jad Q. Ayyad (22330648)
Bashar A. Al‐Rashdan (22330651)
Firas A. Al Quran (22330654)
author2_role author
author
author
author_facet Khaled Q. Al Hamad (21768251)
Jad Q. Ayyad (22330648)
Bashar A. Al‐Rashdan (22330651)
Firas A. Al Quran (22330654)
author_role author
dc.creator.none.fl_str_mv Khaled Q. Al Hamad (21768251)
Jad Q. Ayyad (22330648)
Bashar A. Al‐Rashdan (22330651)
Firas A. Al Quran (22330654)
dc.date.none.fl_str_mv 2025-01-21T06:00:00Z
dc.identifier.none.fl_str_mv 10.1111/jopr.14024
dc.relation.none.fl_str_mv https://figshare.com/articles/journal_contribution/Trueness_and_precision_of_facial_scan_and_virtual_patient_representation_workflow/30234133
dc.rights.none.fl_str_mv CC BY 4.0
info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Biomedical and clinical sciences
Dentistry
Engineering
Biomedical engineering
accuracy
digital dentistry
digital patient
facial scanning
scanners
structured light
dc.title.none.fl_str_mv Trueness and precision of facial scan and virtual patient representation workflow
dc.type.none.fl_str_mv Text
Journal contribution
info:eu-repo/semantics/publishedVersion
text
contribution to journal
description <h3>Purpose</h3><p dir="ltr">To investigate the feasibility and accuracy (trueness and precision) of facial scanning and virtual patient representation (VPR).</p><h3>Materials and Methods</h3><p dir="ltr">One participant was recruited and informed consent was obtained. VPR was performed 30 times with a custom fabricated intraoral scan body (ISB). Thirteen adhesive markers were added to the face as an extraoral scan body (ESB). Two facial scans were obtained for each VPR using an infra‐red laser accessory sensor (Structure sensor; Occipital Inc) mounted on a computer tablet (iPad Pro; Apple Inc), including one with seated ISB and one without ISB. Two maxillary intraoral scans were obtained using an intraoral scanner (Omnicam; Dentsply Sirona) with and without the ISB. All files were imported to a dental software program (exocad; exocad GmbH) and VPR was obtained by aligning the facial and IOS scans using the ISB and ESB as common elements for alignment. Five fiducial face landmarks, four intraoral dental landmarks, and six perioral landmarks were selected for measurements. A total of 32 linear measurements, including 14 face‐face (for facial scan accuracy) and 18 face‐dental (for VPR accuracy) representing total face, lower face, and perioral regions, were performed directly using a digital caliper (FINO Digital Caliper; FINO GmbH) and virtually on the VPR. Trueness was evaluated by mean absolute difference (MAD) between the virtual and direct measurements, and the standard deviation represented Precision. Statistical analyses were performed with a statistical software package (IBM SPSS Statistics v25; IBM Corp), with α = 0.05. Data were analyzed for normality with Shapiro‐Wilk test, and 1‐sample t‐ (or Wilcoxon signed rank test), technical error of measurement (TEM), and relative error magnitude (REM).</p><h3>Results</h3><p dir="ltr">The facial scan had 2.04, 1.66, 0.8 trueness, and 1.05, 0.92, 0.91 precision for total, lower face, and perioral regions. VPR had higher MAD (lower trueness) than facial scan, including 3.32, 2.40, 1.21 trueness and 2.2, 1.47, 1.2 precision for total, lower face, and perioral regions. Both TEM and REM were lowest for the perioral region and increased with increasing measurement distance.</p><h3>Conclusion</h3><p dir="ltr">Error in face scanning increased with increased distance and intricate details. VPR accuracy was lower than face scan accuracy because of added errors in the alignment process. The investigated VPR workflow might be feasible for treatment planning and smile design. However, it would be unreliable for more demanding prostheses manufacturing purposes.</p><h2>Other Information</h2><p dir="ltr">Published in: Journal of Prosthodontics<br>License: <a href="http://creativecommons.org/licenses/by/4.0/" target="_blank">http://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1111/jopr.14024" target="_blank">https://dx.doi.org/10.1111/jopr.14024</a></p>
eu_rights_str_mv openAccess
id Manara2_f421b8651df5106abcc5ee0a689a97e4
identifier_str_mv 10.1111/jopr.14024
network_acronym_str Manara2
network_name_str Manara2
oai_identifier_str oai:figshare.com:article/30234133
publishDate 2025
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv CC BY 4.0
spelling Trueness and precision of facial scan and virtual patient representation workflowKhaled Q. Al Hamad (21768251)Jad Q. Ayyad (22330648)Bashar A. Al‐Rashdan (22330651)Firas A. Al Quran (22330654)Biomedical and clinical sciencesDentistryEngineeringBiomedical engineeringaccuracydigital dentistrydigital patientfacial scanningscannersstructured light<h3>Purpose</h3><p dir="ltr">To investigate the feasibility and accuracy (trueness and precision) of facial scanning and virtual patient representation (VPR).</p><h3>Materials and Methods</h3><p dir="ltr">One participant was recruited and informed consent was obtained. VPR was performed 30 times with a custom fabricated intraoral scan body (ISB). Thirteen adhesive markers were added to the face as an extraoral scan body (ESB). Two facial scans were obtained for each VPR using an infra‐red laser accessory sensor (Structure sensor; Occipital Inc) mounted on a computer tablet (iPad Pro; Apple Inc), including one with seated ISB and one without ISB. Two maxillary intraoral scans were obtained using an intraoral scanner (Omnicam; Dentsply Sirona) with and without the ISB. All files were imported to a dental software program (exocad; exocad GmbH) and VPR was obtained by aligning the facial and IOS scans using the ISB and ESB as common elements for alignment. Five fiducial face landmarks, four intraoral dental landmarks, and six perioral landmarks were selected for measurements. A total of 32 linear measurements, including 14 face‐face (for facial scan accuracy) and 18 face‐dental (for VPR accuracy) representing total face, lower face, and perioral regions, were performed directly using a digital caliper (FINO Digital Caliper; FINO GmbH) and virtually on the VPR. Trueness was evaluated by mean absolute difference (MAD) between the virtual and direct measurements, and the standard deviation represented Precision. Statistical analyses were performed with a statistical software package (IBM SPSS Statistics v25; IBM Corp), with α = 0.05. Data were analyzed for normality with Shapiro‐Wilk test, and 1‐sample t‐ (or Wilcoxon signed rank test), technical error of measurement (TEM), and relative error magnitude (REM).</p><h3>Results</h3><p dir="ltr">The facial scan had 2.04, 1.66, 0.8 trueness, and 1.05, 0.92, 0.91 precision for total, lower face, and perioral regions. VPR had higher MAD (lower trueness) than facial scan, including 3.32, 2.40, 1.21 trueness and 2.2, 1.47, 1.2 precision for total, lower face, and perioral regions. Both TEM and REM were lowest for the perioral region and increased with increasing measurement distance.</p><h3>Conclusion</h3><p dir="ltr">Error in face scanning increased with increased distance and intricate details. VPR accuracy was lower than face scan accuracy because of added errors in the alignment process. The investigated VPR workflow might be feasible for treatment planning and smile design. However, it would be unreliable for more demanding prostheses manufacturing purposes.</p><h2>Other Information</h2><p dir="ltr">Published in: Journal of Prosthodontics<br>License: <a href="http://creativecommons.org/licenses/by/4.0/" target="_blank">http://creativecommons.org/licenses/by/4.0/</a><br>See article on publisher's website: <a href="https://dx.doi.org/10.1111/jopr.14024" target="_blank">https://dx.doi.org/10.1111/jopr.14024</a></p>2025-01-21T06:00:00ZTextJournal contributioninfo:eu-repo/semantics/publishedVersiontextcontribution to journal10.1111/jopr.14024https://figshare.com/articles/journal_contribution/Trueness_and_precision_of_facial_scan_and_virtual_patient_representation_workflow/30234133CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/302341332025-01-21T06:00:00Z
spellingShingle Trueness and precision of facial scan and virtual patient representation workflow
Khaled Q. Al Hamad (21768251)
Biomedical and clinical sciences
Dentistry
Engineering
Biomedical engineering
accuracy
digital dentistry
digital patient
facial scanning
scanners
structured light
status_str publishedVersion
title Trueness and precision of facial scan and virtual patient representation workflow
title_full Trueness and precision of facial scan and virtual patient representation workflow
title_fullStr Trueness and precision of facial scan and virtual patient representation workflow
title_full_unstemmed Trueness and precision of facial scan and virtual patient representation workflow
title_short Trueness and precision of facial scan and virtual patient representation workflow
title_sort Trueness and precision of facial scan and virtual patient representation workflow
topic Biomedical and clinical sciences
Dentistry
Engineering
Biomedical engineering
accuracy
digital dentistry
digital patient
facial scanning
scanners
structured light