Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docx
Objective<p>This study aimed to evaluate the efficacy and safety of flow diverters (FDs) in the treatment of small intracranial aneurysms (≤10 mm).</p>Methods<p>PubMed, Embase, Web of Science, and Cochrane Library were comprehensively searched up to July 2025. Eligible studies incl...
Na minha lista:
| Autor principal: | |
|---|---|
| Outros Autores: | , , , , , , , , , , |
| Publicado em: |
2025
|
| Assuntos: | |
| Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
| _version_ | 1849927624804007936 |
|---|---|
| author | Kuerban Maimaitiaili (22686191) |
| author2 | Maimaitiaili Nuermaimaiti (22686194) Adili Rouzi (22686197) Aisan Seyiti (22686200) Mairidan Yasheng (22686203) Xiong Guo (189516) Moming Abulaiti (22686206) Ying Xiao (6517) Hongbo Pan (5338070) Ainipai Sidike (22686209) Yanbing Hu (5731397) Dawutijiang Yilamu (22686227) |
| author2_role | author author author author author author author author author author author |
| author_facet | Kuerban Maimaitiaili (22686191) Maimaitiaili Nuermaimaiti (22686194) Adili Rouzi (22686197) Aisan Seyiti (22686200) Mairidan Yasheng (22686203) Xiong Guo (189516) Moming Abulaiti (22686206) Ying Xiao (6517) Hongbo Pan (5338070) Ainipai Sidike (22686209) Yanbing Hu (5731397) Dawutijiang Yilamu (22686227) |
| author_role | author |
| dc.creator.none.fl_str_mv | Kuerban Maimaitiaili (22686191) Maimaitiaili Nuermaimaiti (22686194) Adili Rouzi (22686197) Aisan Seyiti (22686200) Mairidan Yasheng (22686203) Xiong Guo (189516) Moming Abulaiti (22686206) Ying Xiao (6517) Hongbo Pan (5338070) Ainipai Sidike (22686209) Yanbing Hu (5731397) Dawutijiang Yilamu (22686227) |
| dc.date.none.fl_str_mv | 2025-11-26T05:14:25Z |
| dc.identifier.none.fl_str_mv | 10.3389/fneur.2025.1706462.s001 |
| dc.relation.none.fl_str_mv | https://figshare.com/articles/dataset/Table_1_Efficacy_and_safety_of_flow_diverters_in_small_intracranial_aneurysms_a_systematic_review_and_single-arm_meta-analysis_docx/30717464 |
| dc.rights.none.fl_str_mv | CC BY 4.0 info:eu-repo/semantics/openAccess |
| dc.subject.none.fl_str_mv | Neurology and Neuromuscular Diseases flow diverters small intracranial aneurysms intracranial aneurysms FDs meta-analysis |
| dc.title.none.fl_str_mv | Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docx |
| dc.type.none.fl_str_mv | Dataset info:eu-repo/semantics/publishedVersion dataset |
| description | Objective<p>This study aimed to evaluate the efficacy and safety of flow diverters (FDs) in the treatment of small intracranial aneurysms (≤10 mm).</p>Methods<p>PubMed, Embase, Web of Science, and Cochrane Library were comprehensively searched up to July 2025. Eligible studies included retrospective cohort studies reporting angiographic and clinical outcomes of FD treatment in small intracranial aneurysms. Data analysis was conducted using STATA 15.0. Pooled proportions and 95% confidence intervals (CIs) were calculated using Freeman–Tukey double arcsine transformation. Publication bias was evaluated using funnel plots and Egger’s test.</p>Results<p>Ten retrospective studies comprising 2,275 patients with 1,938 aneurysms were included. The pooled complete or near-complete occlusion rate was 86% (95% CI: 80–92%). The treatment-related mortality rate was 1% (95% CI: 0–2%), and the hemorrhagic event rate was 1% (95% CI: 1–2%). The ischemic event rate was 2% (95% CI: 1–3%), and the stroke rate was 3% (95% CI: 1–5%). The overall complication rate was 9% (95% CI: 5–12%), while 98% (95% CI: 94–100%) of patients achieved favorable functional outcomes. Egger’s test showed no significant publication bias (p = 0.791).</p>Conclusion<p>FDs appear to be both effective and safe for the treatment of small intracranial aneurysms, achieving high occlusion rates and favorable functional outcomes with low rates of mortality and complications. However, given the high heterogeneity and retrospective nature of the included studies, further large-scale prospective studies are warranted to confirm these findings and refine treatment strategies.</p> |
| eu_rights_str_mv | openAccess |
| id | Manara_11d367c4006c699f37cb49f0908aea84 |
| identifier_str_mv | 10.3389/fneur.2025.1706462.s001 |
| network_acronym_str | Manara |
| network_name_str | ManaraRepo |
| oai_identifier_str | oai:figshare.com:article/30717464 |
| publishDate | 2025 |
| repository.mail.fl_str_mv | |
| repository.name.fl_str_mv | |
| repository_id_str | |
| rights_invalid_str_mv | CC BY 4.0 |
| spelling | Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docxKuerban Maimaitiaili (22686191)Maimaitiaili Nuermaimaiti (22686194)Adili Rouzi (22686197)Aisan Seyiti (22686200)Mairidan Yasheng (22686203)Xiong Guo (189516)Moming Abulaiti (22686206)Ying Xiao (6517)Hongbo Pan (5338070)Ainipai Sidike (22686209)Yanbing Hu (5731397)Dawutijiang Yilamu (22686227)Neurology and Neuromuscular Diseasesflow diverterssmall intracranial aneurysmsintracranial aneurysmsFDsmeta-analysisObjective<p>This study aimed to evaluate the efficacy and safety of flow diverters (FDs) in the treatment of small intracranial aneurysms (≤10 mm).</p>Methods<p>PubMed, Embase, Web of Science, and Cochrane Library were comprehensively searched up to July 2025. Eligible studies included retrospective cohort studies reporting angiographic and clinical outcomes of FD treatment in small intracranial aneurysms. Data analysis was conducted using STATA 15.0. Pooled proportions and 95% confidence intervals (CIs) were calculated using Freeman–Tukey double arcsine transformation. Publication bias was evaluated using funnel plots and Egger’s test.</p>Results<p>Ten retrospective studies comprising 2,275 patients with 1,938 aneurysms were included. The pooled complete or near-complete occlusion rate was 86% (95% CI: 80–92%). The treatment-related mortality rate was 1% (95% CI: 0–2%), and the hemorrhagic event rate was 1% (95% CI: 1–2%). The ischemic event rate was 2% (95% CI: 1–3%), and the stroke rate was 3% (95% CI: 1–5%). The overall complication rate was 9% (95% CI: 5–12%), while 98% (95% CI: 94–100%) of patients achieved favorable functional outcomes. Egger’s test showed no significant publication bias (p = 0.791).</p>Conclusion<p>FDs appear to be both effective and safe for the treatment of small intracranial aneurysms, achieving high occlusion rates and favorable functional outcomes with low rates of mortality and complications. However, given the high heterogeneity and retrospective nature of the included studies, further large-scale prospective studies are warranted to confirm these findings and refine treatment strategies.</p>2025-11-26T05:14:25ZDatasetinfo:eu-repo/semantics/publishedVersiondataset10.3389/fneur.2025.1706462.s001https://figshare.com/articles/dataset/Table_1_Efficacy_and_safety_of_flow_diverters_in_small_intracranial_aneurysms_a_systematic_review_and_single-arm_meta-analysis_docx/30717464CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/307174642025-11-26T05:14:25Z |
| spellingShingle | Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docx Kuerban Maimaitiaili (22686191) Neurology and Neuromuscular Diseases flow diverters small intracranial aneurysms intracranial aneurysms FDs meta-analysis |
| status_str | publishedVersion |
| title | Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docx |
| title_full | Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docx |
| title_fullStr | Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docx |
| title_full_unstemmed | Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docx |
| title_short | Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docx |
| title_sort | Table 1_Efficacy and safety of flow diverters in small intracranial aneurysms: a systematic review and single-arm meta-analysis.docx |
| topic | Neurology and Neuromuscular Diseases flow diverters small intracranial aneurysms intracranial aneurysms FDs meta-analysis |