Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4

Background<p>Transcatheter aortic valve implantation (TAVI) has gained widespread clinical acceptance owing to its minimally invasive approach and enhanced postoperative recovery. This study developed a standardized ovine aortic stenosis (AS) model through surgical implantation of a circular b...

Full description

Saved in:
Bibliographic Details
Main Author: Yan Zhu (112437) (author)
Other Authors: Nana Qin (11472282) (author), Jie Hou (130874) (author), Baoyin Li (1745980) (author), Fangxu Liu (22678985) (author), Xin Jiang (6348) (author), Zhuo Chen (135585) (author), Xiongtao Lin (22678988) (author), Xiaohang Tong (247126) (author), Xufeng Wei (22678991) (author), Dejian Li (769540) (author), Mengsi Hu (12433419) (author)
Published: 2025
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849927636603633664
author Yan Zhu (112437)
author2 Nana Qin (11472282)
Jie Hou (130874)
Baoyin Li (1745980)
Fangxu Liu (22678985)
Xin Jiang (6348)
Zhuo Chen (135585)
Xiongtao Lin (22678988)
Xiaohang Tong (247126)
Xufeng Wei (22678991)
Dejian Li (769540)
Mengsi Hu (12433419)
author2_role author
author
author
author
author
author
author
author
author
author
author
author_facet Yan Zhu (112437)
Nana Qin (11472282)
Jie Hou (130874)
Baoyin Li (1745980)
Fangxu Liu (22678985)
Xin Jiang (6348)
Zhuo Chen (135585)
Xiongtao Lin (22678988)
Xiaohang Tong (247126)
Xufeng Wei (22678991)
Dejian Li (769540)
Mengsi Hu (12433419)
author_role author
dc.creator.none.fl_str_mv Yan Zhu (112437)
Nana Qin (11472282)
Jie Hou (130874)
Baoyin Li (1745980)
Fangxu Liu (22678985)
Xin Jiang (6348)
Zhuo Chen (135585)
Xiongtao Lin (22678988)
Xiaohang Tong (247126)
Xufeng Wei (22678991)
Dejian Li (769540)
Mengsi Hu (12433419)
dc.date.none.fl_str_mv 2025-11-25T06:15:34Z
dc.identifier.none.fl_str_mv 10.3389/fcvm.2025.1663130.s001
dc.relation.none.fl_str_mv https://figshare.com/articles/media/Video_3_Development_of_a_standardized_ovine_aortic_stenosis_model_a_pathomimetic_platform_for_TAVI_evaluation_and_durability_testing_mp4/30703694
dc.rights.none.fl_str_mv CC BY 4.0
info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Cardiology
aortic stenosis
TAVI
sheep model
hemodynamics
calcification
dc.title.none.fl_str_mv Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4
dc.type.none.fl_str_mv Dataset
Media
info:eu-repo/semantics/publishedVersion
dataset
description Background<p>Transcatheter aortic valve implantation (TAVI) has gained widespread clinical acceptance owing to its minimally invasive approach and enhanced postoperative recovery. This study developed a standardized ovine aortic stenosis (AS) model through surgical implantation of a circular bioengineered annular stent in the aortic root, creating a reproducible pathomimetic platform for TAVI evaluation. Following hemodynamic stabilization, TAVI procedures were performed to systematically assess mid-to-long-term valve functionality and calcification progression.</p>Methods<p>AS model was established in 11 sheep using extracorporeal circulation assistance technology. Following hemodynamic stabilization (2–4 weeks), TAVI was performed. The modeled sheep were divided into two groups to monitor valve conditions at 3 months (n = 6) and 6 months (n = 5), respectively. Additionally, a non-modeled control group was established, with valve conditions assessed at 3 months (n = 2) and 6 months (n = 1). Preoperative ultrasound data, collected on the day of TAVI, which served as the baseline. Key hemodynamic parameters including blood flow velocity, transvalvular pressure gradient, and left ventricular ejection fraction were measured at 30, 90, and 180 days postoperatively, in accordance with Valve Academic Research Consortium-3 (VARC-3), to evaluate temporal changes in hemodynamics. The effects of the AS model on valve function were further analyzed by integrating final histopathological findings and calcification degree outcomes.</p>Results<p>Successful AS model establishment was achieved in all 11 sheep, with significant increases in mean transvalvular pressure gradient (Δ+17.98 ± 12.71 mmHg) and peak flow velocity observed post-modeling (Δ+ 2.23 ± 0.38 m/s). Post-TAVI evaluation demonstrated progressive hemodynamic normalization, achieving pre-modeling levels (1.72 vs. 6.91 mmHg, P = 0.058/0.80 vs. 1.51 m/s, P = 0.065) at 180-day follow-up. LVEF remained stable throughout the experimental period. Histopathological analysis indicated comparable calcification burden between 90 and 180 days (Calcium Content: P = 0.7459 and Calcification Score: P = 0.5455).</p>Conclusions<p>The surgically induced ovine AS model effectively replicates clinically relevant hemodynamic perturbations while maintaining excellent procedural feasibility. TAVI in this model achieves complete hemodynamic normalization without accelerating bioprosthetic valve degeneration or calcification. This standardized preclinical platform enables rigorous evaluation of TAVI device performance and durability, providing robust scientific validation for translational applications.</p>
eu_rights_str_mv openAccess
id Manara_3446ba2411410f8874f0ac96fff53049
identifier_str_mv 10.3389/fcvm.2025.1663130.s001
network_acronym_str Manara
network_name_str ManaraRepo
oai_identifier_str oai:figshare.com:article/30703694
publishDate 2025
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv CC BY 4.0
spelling Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4Yan Zhu (112437)Nana Qin (11472282)Jie Hou (130874)Baoyin Li (1745980)Fangxu Liu (22678985)Xin Jiang (6348)Zhuo Chen (135585)Xiongtao Lin (22678988)Xiaohang Tong (247126)Xufeng Wei (22678991)Dejian Li (769540)Mengsi Hu (12433419)Cardiologyaortic stenosisTAVIsheep modelhemodynamicscalcificationBackground<p>Transcatheter aortic valve implantation (TAVI) has gained widespread clinical acceptance owing to its minimally invasive approach and enhanced postoperative recovery. This study developed a standardized ovine aortic stenosis (AS) model through surgical implantation of a circular bioengineered annular stent in the aortic root, creating a reproducible pathomimetic platform for TAVI evaluation. Following hemodynamic stabilization, TAVI procedures were performed to systematically assess mid-to-long-term valve functionality and calcification progression.</p>Methods<p>AS model was established in 11 sheep using extracorporeal circulation assistance technology. Following hemodynamic stabilization (2–4 weeks), TAVI was performed. The modeled sheep were divided into two groups to monitor valve conditions at 3 months (n = 6) and 6 months (n = 5), respectively. Additionally, a non-modeled control group was established, with valve conditions assessed at 3 months (n = 2) and 6 months (n = 1). Preoperative ultrasound data, collected on the day of TAVI, which served as the baseline. Key hemodynamic parameters including blood flow velocity, transvalvular pressure gradient, and left ventricular ejection fraction were measured at 30, 90, and 180 days postoperatively, in accordance with Valve Academic Research Consortium-3 (VARC-3), to evaluate temporal changes in hemodynamics. The effects of the AS model on valve function were further analyzed by integrating final histopathological findings and calcification degree outcomes.</p>Results<p>Successful AS model establishment was achieved in all 11 sheep, with significant increases in mean transvalvular pressure gradient (Δ+17.98 ± 12.71 mmHg) and peak flow velocity observed post-modeling (Δ+ 2.23 ± 0.38 m/s). Post-TAVI evaluation demonstrated progressive hemodynamic normalization, achieving pre-modeling levels (1.72 vs. 6.91 mmHg, P = 0.058/0.80 vs. 1.51 m/s, P = 0.065) at 180-day follow-up. LVEF remained stable throughout the experimental period. Histopathological analysis indicated comparable calcification burden between 90 and 180 days (Calcium Content: P = 0.7459 and Calcification Score: P = 0.5455).</p>Conclusions<p>The surgically induced ovine AS model effectively replicates clinically relevant hemodynamic perturbations while maintaining excellent procedural feasibility. TAVI in this model achieves complete hemodynamic normalization without accelerating bioprosthetic valve degeneration or calcification. This standardized preclinical platform enables rigorous evaluation of TAVI device performance and durability, providing robust scientific validation for translational applications.</p>2025-11-25T06:15:34ZDatasetMediainfo:eu-repo/semantics/publishedVersiondataset10.3389/fcvm.2025.1663130.s001https://figshare.com/articles/media/Video_3_Development_of_a_standardized_ovine_aortic_stenosis_model_a_pathomimetic_platform_for_TAVI_evaluation_and_durability_testing_mp4/30703694CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/307036942025-11-25T06:15:34Z
spellingShingle Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4
Yan Zhu (112437)
Cardiology
aortic stenosis
TAVI
sheep model
hemodynamics
calcification
status_str publishedVersion
title Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4
title_full Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4
title_fullStr Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4
title_full_unstemmed Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4
title_short Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4
title_sort Video 3_Development of a standardized ovine aortic stenosis model: a pathomimetic platform for TAVI evaluation and durability testing.mp4
topic Cardiology
aortic stenosis
TAVI
sheep model
hemodynamics
calcification