Objective<p>Osseointegration is a critical determinant of the long-term stability and functional performance of orthopedic implants, with prosthetic morphology exerting substantial influence on biomechanical loading and bone–implant interface dynamics. This study aimed to evaluate the biomecha...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Zi-Xuan Guo (22817582) (author)
مؤلفون آخرون: Zhen Wang (72451) (author), Xue-Lin Zhao (22817585) (author), Cheng-Wei Cao (22817588) (author), Zi-Fu Huang (22817591) (author), Zhao-Hang Sun (22817594) (author), Yu-Shu Zheng (22817597) (author), Meng Xu (62933) (author)
منشور في: 2025
الموضوعات:
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1852014057414983680
author Zi-Xuan Guo (22817582)
author2 Zhen Wang (72451)
Xue-Lin Zhao (22817585)
Cheng-Wei Cao (22817588)
Zi-Fu Huang (22817591)
Zhao-Hang Sun (22817594)
Yu-Shu Zheng (22817597)
Meng Xu (62933)
author2_role author
author
author
author
author
author
author
author_facet Zi-Xuan Guo (22817582)
Zhen Wang (72451)
Xue-Lin Zhao (22817585)
Cheng-Wei Cao (22817588)
Zi-Fu Huang (22817591)
Zhao-Hang Sun (22817594)
Yu-Shu Zheng (22817597)
Meng Xu (62933)
author_role author
dc.creator.none.fl_str_mv Zi-Xuan Guo (22817582)
Zhen Wang (72451)
Xue-Lin Zhao (22817585)
Cheng-Wei Cao (22817588)
Zi-Fu Huang (22817591)
Zhao-Hang Sun (22817594)
Yu-Shu Zheng (22817597)
Meng Xu (62933)
dc.date.none.fl_str_mv 2025-12-10T06:31:18Z
dc.identifier.none.fl_str_mv 10.3389/fbioe.2025.1694169.s002
dc.relation.none.fl_str_mv https://figshare.com/articles/figure/Image_1_Finite_element_analysis_of_the_biomechanical_behavior_of_four_osseointegrated_prosthetic_designs_tif/30845822
dc.rights.none.fl_str_mv CC BY 4.0
info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Biotechnology
finite element
osseointegrated prosthesis
stress shielding
analysis
biomechanical
dc.title.none.fl_str_mv Image 1_Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.tif
dc.type.none.fl_str_mv Image
Figure
info:eu-repo/semantics/publishedVersion
image
description Objective<p>Osseointegration is a critical determinant of the long-term stability and functional performance of orthopedic implants, with prosthetic morphology exerting substantial influence on biomechanical loading and bone–implant interface dynamics. This study aimed to evaluate the biomechanical behavior of four representative osseointegrated prosthetic designs using finite element analysis, to inform clinical application and guide optimization in prosthetic design.</p>Methods<p>Three-dimensional finite element models were constructed to simulate host bone integrated with four distinct prosthetic configurations: (1) a threaded prosthesis representing the Osseointegrated Prostheses for the Rehabilitation of Amputees system, (2) a smooth press-fit prosthesis simulating the Osseointegrated Prosthetic Limb, (3) a titanium alloy prosthesis with a multi-porous surface, and (4) a molybdenum-rhenium (Mo-Re) alloy prosthesis with a multi-porous surface. Simulated physiological loading conditions were applied to evaluate stress distribution within prosthetic structures, interfacial mechanics at the bone-prosthesis junction, and stress transfer to surrounding osseous tissue.</p>Results<p>All four prosthetic designs exhibited stress concentration at the distal stem region, with peak stress values ranging from 179 to 185 MPa, indicating comparable load-bearing characteristics. Incorporation of a multi-porous surface effectively reduced stress concentration on the inner cortical wall associated with groove geometry. The two multi-porous configurations demonstrated similar load transfer patterns, with maximum stress in adjacent bone tissue recorded at 20.4 MPa. The Mo–Re alloy prosthesis exhibited reduced deformation under equivalent loading due to its higher elastic modulus. Maximum stress within the porous section was 5.3 MPa for the Mo–Re prosthesis and 9.3 MPa for the titanium alloy variant, with no evidence of critical stress accumulation.</p>Conclusion<p>The multi-porous Mo–Re alloy prosthesis demonstrated favorable mechanical compatibility through the optimized integration of material properties and structural design. Findings from the finite element analysis support its potential utility in osseointegrated orthopedic applications.</p>
eu_rights_str_mv openAccess
id Manara_65823b338bd4c463eb00a608a3fd8883
identifier_str_mv 10.3389/fbioe.2025.1694169.s002
network_acronym_str Manara
network_name_str ManaraRepo
oai_identifier_str oai:figshare.com:article/30845822
publishDate 2025
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv CC BY 4.0
spelling Image 1_Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.tifZi-Xuan Guo (22817582)Zhen Wang (72451)Xue-Lin Zhao (22817585)Cheng-Wei Cao (22817588)Zi-Fu Huang (22817591)Zhao-Hang Sun (22817594)Yu-Shu Zheng (22817597)Meng Xu (62933)Biotechnologyfinite elementosseointegrated prosthesisstress shieldinganalysisbiomechanicalObjective<p>Osseointegration is a critical determinant of the long-term stability and functional performance of orthopedic implants, with prosthetic morphology exerting substantial influence on biomechanical loading and bone–implant interface dynamics. This study aimed to evaluate the biomechanical behavior of four representative osseointegrated prosthetic designs using finite element analysis, to inform clinical application and guide optimization in prosthetic design.</p>Methods<p>Three-dimensional finite element models were constructed to simulate host bone integrated with four distinct prosthetic configurations: (1) a threaded prosthesis representing the Osseointegrated Prostheses for the Rehabilitation of Amputees system, (2) a smooth press-fit prosthesis simulating the Osseointegrated Prosthetic Limb, (3) a titanium alloy prosthesis with a multi-porous surface, and (4) a molybdenum-rhenium (Mo-Re) alloy prosthesis with a multi-porous surface. Simulated physiological loading conditions were applied to evaluate stress distribution within prosthetic structures, interfacial mechanics at the bone-prosthesis junction, and stress transfer to surrounding osseous tissue.</p>Results<p>All four prosthetic designs exhibited stress concentration at the distal stem region, with peak stress values ranging from 179 to 185 MPa, indicating comparable load-bearing characteristics. Incorporation of a multi-porous surface effectively reduced stress concentration on the inner cortical wall associated with groove geometry. The two multi-porous configurations demonstrated similar load transfer patterns, with maximum stress in adjacent bone tissue recorded at 20.4 MPa. The Mo–Re alloy prosthesis exhibited reduced deformation under equivalent loading due to its higher elastic modulus. Maximum stress within the porous section was 5.3 MPa for the Mo–Re prosthesis and 9.3 MPa for the titanium alloy variant, with no evidence of critical stress accumulation.</p>Conclusion<p>The multi-porous Mo–Re alloy prosthesis demonstrated favorable mechanical compatibility through the optimized integration of material properties and structural design. Findings from the finite element analysis support its potential utility in osseointegrated orthopedic applications.</p>2025-12-10T06:31:18ZImageFigureinfo:eu-repo/semantics/publishedVersionimage10.3389/fbioe.2025.1694169.s002https://figshare.com/articles/figure/Image_1_Finite_element_analysis_of_the_biomechanical_behavior_of_four_osseointegrated_prosthetic_designs_tif/30845822CC BY 4.0info:eu-repo/semantics/openAccessoai:figshare.com:article/308458222025-12-10T06:31:18Z
spellingShingle Image 1_Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.tif
Zi-Xuan Guo (22817582)
Biotechnology
finite element
osseointegrated prosthesis
stress shielding
analysis
biomechanical
status_str publishedVersion
title Image 1_Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.tif
title_full Image 1_Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.tif
title_fullStr Image 1_Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.tif
title_full_unstemmed Image 1_Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.tif
title_short Image 1_Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.tif
title_sort Image 1_Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.tif
topic Biotechnology
finite element
osseointegrated prosthesis
stress shielding
analysis
biomechanical