Performance characteristics of an ammonia-water absorption heat pump system

The influences of the performance parameters and the heat transfer characteristics of the absorption heat pump using ammonia-water mixture are theoretically carried out. There is a pronounced effect of the ammonia concentration ξ after rectifier on the temperature glides that has been investigated....

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Gadalla, Mohamed (author)
مؤلفون آخرون: Talaat A., Ibrahim (author), Hassan, Mohammed A.M (author)
التنسيق: article
منشور في: 2013
الوصول للمادة أونلاين:http://hdl.handle.net/11073/8560
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513441253818368
author Gadalla, Mohamed
author2 Talaat A., Ibrahim
Hassan, Mohammed A.M
author2_role author
author
author_facet Gadalla, Mohamed
Talaat A., Ibrahim
Hassan, Mohammed A.M
author_role author
dc.creator.none.fl_str_mv Gadalla, Mohamed
Talaat A., Ibrahim
Hassan, Mohammed A.M
dc.date.none.fl_str_mv 2013-11
2016-10-20T06:19:26Z
2016-10-20T06:19:26Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv Gadalla, Mohamed, Talaat A. Ibrahim, and Mohamed A.M. Hassan. "Performance characteristics of an ammonia-water absorption heat pump system." International Journal of Energy Research 37, no. 4 (2013): 1917-1927
1099-114X
http://hdl.handle.net/11073/8560
10.1002/er.2992
dc.language.none.fl_str_mv en_US
dc.relation.none.fl_str_mv International Journal of Energy Research
http://dx.doi.org/10.1002/er.2992
dc.title.none.fl_str_mv Performance characteristics of an ammonia-water absorption heat pump system
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description The influences of the performance parameters and the heat transfer characteristics of the absorption heat pump using ammonia-water mixture are theoretically carried out. There is a pronounced effect of the ammonia concentration ξ after rectifier on the temperature glides that has been investigated. At ξ=0.9000 and saturation pressures of 75 and 0.5bar, the temperature glides are 64.4°C and 81.21°C, respectively, whereas these glides are 0°C and 16.1°C at ξ=0.9999 and at the same pressures. This mixture property considerably affects the absorption system performance and the design of the rectifier as well as other absorption components. A correlation of the Nusselt number, Nu, is developed and compared with some published work in the literature for plate type heat exchanger. The effects of ammonia concentration ξ, mass fraction spread Δξ, specific solution circulation ratio f, and pressure ratio Rp on the refrigerant mass flow rate, the pressure drop, and the heat transfer coefficients during the condensation, the evaporation, and the absorption processes are investigated. It was found that increasing ammonia mass fraction spread Δξ results in both specific circulation ratio f and Rp that have insignificant effects on the refrigerant mass flow rate. Mounting Δξ at constant f reduces the pressure drop gradually and subsequently starts to increase as Δξ escalates. The ammonia concentration ξ has insignificant effect on the evaporation heat transfer coefficient but has a little effect on the condensation and the absorber heat transfer coefficients. The ammonia mass fraction spread Δξ and f have considerable effects on the heat transfer coefficient for different absorption heat pump components. Rp has a pronounced effect on the evaporation heat transfer coefficient, although it has a slight effect on the condensation and the absorber heat transfer coefficients. The effect of Rp on the heat transfer coefficient may be eliminated in the absorber for Δξ>0.18.
format article
id aus_02eed30699c6329969b7a00370ffa7f1
identifier_str_mv Gadalla, Mohamed, Talaat A. Ibrahim, and Mohamed A.M. Hassan. "Performance characteristics of an ammonia-water absorption heat pump system." International Journal of Energy Research 37, no. 4 (2013): 1917-1927
1099-114X
10.1002/er.2992
language_invalid_str_mv en_US
network_acronym_str aus
network_name_str aus
oai_identifier_str oai:repository.aus.edu:11073/8560
publishDate 2013
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Performance characteristics of an ammonia-water absorption heat pump systemGadalla, MohamedTalaat A., IbrahimHassan, Mohammed A.MThe influences of the performance parameters and the heat transfer characteristics of the absorption heat pump using ammonia-water mixture are theoretically carried out. There is a pronounced effect of the ammonia concentration ξ after rectifier on the temperature glides that has been investigated. At ξ=0.9000 and saturation pressures of 75 and 0.5bar, the temperature glides are 64.4°C and 81.21°C, respectively, whereas these glides are 0°C and 16.1°C at ξ=0.9999 and at the same pressures. This mixture property considerably affects the absorption system performance and the design of the rectifier as well as other absorption components. A correlation of the Nusselt number, Nu, is developed and compared with some published work in the literature for plate type heat exchanger. The effects of ammonia concentration ξ, mass fraction spread Δξ, specific solution circulation ratio f, and pressure ratio Rp on the refrigerant mass flow rate, the pressure drop, and the heat transfer coefficients during the condensation, the evaporation, and the absorption processes are investigated. It was found that increasing ammonia mass fraction spread Δξ results in both specific circulation ratio f and Rp that have insignificant effects on the refrigerant mass flow rate. Mounting Δξ at constant f reduces the pressure drop gradually and subsequently starts to increase as Δξ escalates. The ammonia concentration ξ has insignificant effect on the evaporation heat transfer coefficient but has a little effect on the condensation and the absorber heat transfer coefficients. The ammonia mass fraction spread Δξ and f have considerable effects on the heat transfer coefficient for different absorption heat pump components. Rp has a pronounced effect on the evaporation heat transfer coefficient, although it has a slight effect on the condensation and the absorber heat transfer coefficients. The effect of Rp on the heat transfer coefficient may be eliminated in the absorber for Δξ>0.18.2016-10-20T06:19:26Z2016-10-20T06:19:26Z2013-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfGadalla, Mohamed, Talaat A. Ibrahim, and Mohamed A.M. Hassan. "Performance characteristics of an ammonia-water absorption heat pump system." International Journal of Energy Research 37, no. 4 (2013): 1917-19271099-114Xhttp://hdl.handle.net/11073/856010.1002/er.2992en_USInternational Journal of Energy Researchhttp://dx.doi.org/10.1002/er.2992oai:repository.aus.edu:11073/85602024-08-22T12:16:38Z
spellingShingle Performance characteristics of an ammonia-water absorption heat pump system
Gadalla, Mohamed
status_str publishedVersion
title Performance characteristics of an ammonia-water absorption heat pump system
title_full Performance characteristics of an ammonia-water absorption heat pump system
title_fullStr Performance characteristics of an ammonia-water absorption heat pump system
title_full_unstemmed Performance characteristics of an ammonia-water absorption heat pump system
title_short Performance characteristics of an ammonia-water absorption heat pump system
title_sort Performance characteristics of an ammonia-water absorption heat pump system
url http://hdl.handle.net/11073/8560