Performance Evaluation of a Thermal Energy Storage

The direct contact heat transfer technique gives better heat transfer rates. In this paper, the operation of a simple system was simulated under different operating conditions. During the charging mode of the operation, refrigerant R134a is injected into water stored in an evaporator to exchange dir...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Gadalla, Mohamed (author)
مؤلفون آخرون: Ahmed, Saad (author)
التنسيق: article
منشور في: 2013
الموضوعات:
الوصول للمادة أونلاين:http://hdl.handle.net/11073/8212
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513436193390592
author Gadalla, Mohamed
author2 Ahmed, Saad
author2_role author
author_facet Gadalla, Mohamed
Ahmed, Saad
author_role author
dc.creator.none.fl_str_mv Gadalla, Mohamed
Ahmed, Saad
dc.date.none.fl_str_mv 2013-02
2016-03-07T08:58:01Z
2016-03-07T08:58:01Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv Gadalla, Mohamed, and Saad Ahmed. "Performance evaluation of a thermal energy storage." Applied Mechanics and Materials 291-294 (2013): 642-647.
1662-7482
http://hdl.handle.net/11073/8212
10.4028/www.scientific.net/AMM.291-294.642
dc.language.none.fl_str_mv en_US
dc.relation.none.fl_str_mv http://www.scientific.net/AMM.291-294.642
dc.subject.none.fl_str_mv Direct Contact Heat Exchanger
Refrigeration Cycle
Thermal Energy Storage TES
dc.title.none.fl_str_mv Performance Evaluation of a Thermal Energy Storage
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description The direct contact heat transfer technique gives better heat transfer rates. In this paper, the operation of a simple system was simulated under different operating conditions. During the charging mode of the operation, refrigerant R134a is injected into water stored in an evaporator to exchange directly heat with the water and form clathrates. Later, the clathrate is used to cool water which is used for air-conditioning purposes. Direct contact charging and/or discharging eliminate the necessity of a heat exchanger inside the storage tank and leads to an effective heat transfer method. The results indicate that the performance of the system depends on the refrigerant type, compressor speed and the mass flow rate of the refrigerant.
format article
id aus_1611bab119a67a26653227778eaaffc6
identifier_str_mv Gadalla, Mohamed, and Saad Ahmed. "Performance evaluation of a thermal energy storage." Applied Mechanics and Materials 291-294 (2013): 642-647.
1662-7482
10.4028/www.scientific.net/AMM.291-294.642
language_invalid_str_mv en_US
network_acronym_str aus
network_name_str aus
oai_identifier_str oai:repository.aus.edu:11073/8212
publishDate 2013
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Performance Evaluation of a Thermal Energy StorageGadalla, MohamedAhmed, SaadDirect Contact Heat ExchangerRefrigeration CycleThermal Energy Storage TESThe direct contact heat transfer technique gives better heat transfer rates. In this paper, the operation of a simple system was simulated under different operating conditions. During the charging mode of the operation, refrigerant R134a is injected into water stored in an evaporator to exchange directly heat with the water and form clathrates. Later, the clathrate is used to cool water which is used for air-conditioning purposes. Direct contact charging and/or discharging eliminate the necessity of a heat exchanger inside the storage tank and leads to an effective heat transfer method. The results indicate that the performance of the system depends on the refrigerant type, compressor speed and the mass flow rate of the refrigerant.2016-03-07T08:58:01Z2016-03-07T08:58:01Z2013-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfGadalla, Mohamed, and Saad Ahmed. "Performance evaluation of a thermal energy storage." Applied Mechanics and Materials 291-294 (2013): 642-647.1662-7482http://hdl.handle.net/11073/821210.4028/www.scientific.net/AMM.291-294.642en_UShttp://www.scientific.net/AMM.291-294.642oai:repository.aus.edu:11073/82122024-08-22T12:16:27Z
spellingShingle Performance Evaluation of a Thermal Energy Storage
Gadalla, Mohamed
Direct Contact Heat Exchanger
Refrigeration Cycle
Thermal Energy Storage TES
status_str publishedVersion
title Performance Evaluation of a Thermal Energy Storage
title_full Performance Evaluation of a Thermal Energy Storage
title_fullStr Performance Evaluation of a Thermal Energy Storage
title_full_unstemmed Performance Evaluation of a Thermal Energy Storage
title_short Performance Evaluation of a Thermal Energy Storage
title_sort Performance Evaluation of a Thermal Energy Storage
topic Direct Contact Heat Exchanger
Refrigeration Cycle
Thermal Energy Storage TES
url http://hdl.handle.net/11073/8212