Integrated Renewable Energy Options for HVAC-Cooling Systems

A Master of Science thesis in Mechanical Engineering by Amani Shaheen Ali Al Hammadi entitled, "Integrated Renewable Energy Options for HVAC-Cooling Systems," submitted in June 2013. Thesis advisor is Dr. Mohamed Gadalla. Available are both soft and hard copies of the thesis.

Saved in:
Bibliographic Details
Main Author: Al Hammadi, Amani Shaheen Ali (author)
Format: doctoralThesis
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/11073/5908
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1864513438003232768
author Al Hammadi, Amani Shaheen Ali
author_facet Al Hammadi, Amani Shaheen Ali
author_role author
dc.contributor.none.fl_str_mv Gadalla, Mohamed
dc.creator.none.fl_str_mv Al Hammadi, Amani Shaheen Ali
dc.date.none.fl_str_mv 2013-09-11T08:34:38Z
2013-09-11T08:34:38Z
2013-06
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv 35.232-2013.35
http://hdl.handle.net/11073/5908
dc.language.none.fl_str_mv en_US
dc.subject.none.fl_str_mv HVAC
PEM fuel cell
flat plate solar collector
parabolic trough solar collector
PV/T
double effect
triple effect
Air conditioning
Design and construction
Fuel cells
Solar collectors
dc.title.none.fl_str_mv Integrated Renewable Energy Options for HVAC-Cooling Systems
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/doctoralThesis
description A Master of Science thesis in Mechanical Engineering by Amani Shaheen Ali Al Hammadi entitled, "Integrated Renewable Energy Options for HVAC-Cooling Systems," submitted in June 2013. Thesis advisor is Dr. Mohamed Gadalla. Available are both soft and hard copies of the thesis.
format doctoralThesis
id aus_78ec1e03ee4ae821635e346c5cc430e1
identifier_str_mv 35.232-2013.35
language_invalid_str_mv en_US
network_acronym_str aus
network_name_str aus
oai_identifier_str oai:repository.aus.edu:11073/5908
publishDate 2013
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Integrated Renewable Energy Options for HVAC-Cooling SystemsAl Hammadi, Amani Shaheen AliHVACPEM fuel cellflat plate solar collectorparabolic trough solar collectorPV/Tdouble effecttriple effectAir conditioningDesign and constructionFuel cellsSolar collectorsA Master of Science thesis in Mechanical Engineering by Amani Shaheen Ali Al Hammadi entitled, "Integrated Renewable Energy Options for HVAC-Cooling Systems," submitted in June 2013. Thesis advisor is Dr. Mohamed Gadalla. Available are both soft and hard copies of the thesis.The demand for energy is increasing at an unexpected rate all over the world. Most of the present worldwide energy usage is based on fossil fuel and results in continuous depletion of this resource. Conventional Heating Ventilation and Air conditioning (HVAC) cooling systems are the dominant source of power consumption. These systems have some problems such as low performance, high emissions, and high costs. So, more economically and environmentally friendly HVAC systems are desired which can provide the required power while saving energy and having high performance and low emissions to the environment. In this thesis, fuel cells and solar collectors are integrated with absorption cooling systems for sustainable development. This thesis examines the Coefficient of Performance (COP) and/or overall efficiency of a Proton Exchange Membrane Fuel Cell (PEMFC), Flat Plate Solar Collector (FPSC), Parabolic Trough Solar Collector (PTSC), and Photovoltaic-Thermal Collector (PV/T) integrated with Double Effect and Triple Effect Absorption Systems (DEAS and TEAS) to produce 10 kW of cooling capacity. A computer program is developed using Engineering Equation Solver (EES) software. The software is used to obtain all required thermodynamic properties of a water-lithium bromide (H2O/LiBr) solution and to carry out detailed energy and exergy analyses for each integrated system. The analyses show that the PEMFC system integrated with DEAS results in the highest COP. This is followed by the PV/T integrated with TEAS. The maximum energetic and exergetic COPs obtained for PEMFC integrated with DEAS are 2.70 and 2.30, respectively, while those obtained for PV/T integrated with TEAS are 2.32 and 2.06, respectively. However, the integration of PEMFC, PTSC, and PV/T with DEAS results in improved COP where the maximum energetic and exergetic COPs obtained are 2.94 and 2.50, respectively. Thus, this hybrid system is considered to be the optimum design from the performance point of view. This research provides a new interpretation of how alternative energy is utilized in operating HVAC cooling systems and presents a new insight into the most sustainable integrated systems that can be applied in residential and commercial buildings in the UAE.College of EngineeringDepartment of Mechanical EngineeringMaster of Science in Mechanical Engineering (MSME)Gadalla, Mohamed2013-09-11T08:34:38Z2013-09-11T08:34:38Z2013-06info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdf35.232-2013.35http://hdl.handle.net/11073/5908en_USoai:repository.aus.edu:11073/59082025-06-26T12:25:27Z
spellingShingle Integrated Renewable Energy Options for HVAC-Cooling Systems
Al Hammadi, Amani Shaheen Ali
HVAC
PEM fuel cell
flat plate solar collector
parabolic trough solar collector
PV/T
double effect
triple effect
Air conditioning
Design and construction
Fuel cells
Solar collectors
status_str publishedVersion
title Integrated Renewable Energy Options for HVAC-Cooling Systems
title_full Integrated Renewable Energy Options for HVAC-Cooling Systems
title_fullStr Integrated Renewable Energy Options for HVAC-Cooling Systems
title_full_unstemmed Integrated Renewable Energy Options for HVAC-Cooling Systems
title_short Integrated Renewable Energy Options for HVAC-Cooling Systems
title_sort Integrated Renewable Energy Options for HVAC-Cooling Systems
topic HVAC
PEM fuel cell
flat plate solar collector
parabolic trough solar collector
PV/T
double effect
triple effect
Air conditioning
Design and construction
Fuel cells
Solar collectors
url http://hdl.handle.net/11073/5908