Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes

Targeted liposomes triggered by ultrasound are a promising drug delivery system as they potentially improve the clinical outcomes of chemotherapy while reducing associated side effects. In this work, a comprehensive model fitting was performed for a large dataset of liposomal release profiles with s...

Full description

Saved in:
Bibliographic Details
Main Author: Almajed, Zeyad Mohamed (author)
Other Authors: Salkho, Najla (author), Sulieman, Hana (author), Husseini, Ghaleb (author)
Format: article
Published: 2022
Subjects:
Online Access:http://hdl.handle.net/11073/25088
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1864513443270230016
author Almajed, Zeyad Mohamed
author2 Salkho, Najla
Sulieman, Hana
Husseini, Ghaleb
author2_role author
author
author
author_facet Almajed, Zeyad Mohamed
Salkho, Najla
Sulieman, Hana
Husseini, Ghaleb
author_role author
dc.creator.none.fl_str_mv Almajed, Zeyad Mohamed
Salkho, Najla
Sulieman, Hana
Husseini, Ghaleb
dc.date.none.fl_str_mv 2022-12-07T10:22:53Z
2022-12-07T10:22:53Z
2022-12-05
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv AlMajed, Z.; Salkho, N.M.; Sulieman, H.; Husseini, G.A. Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes. Biomedicines 2022, 10, 3139. https://doi.org/10.3390/biomedicines10123139
2227-9059
http://hdl.handle.net/11073/25088
10.3390/biomedicines10123139
dc.language.none.fl_str_mv en_US
dc.publisher.none.fl_str_mv MDPI
dc.relation.none.fl_str_mv https://doi.org/10.3390/biomedicines10123139
dc.subject.none.fl_str_mv Drug delivery systems
Cancer treatment
Liposomes
Ligand targeting
Ultrasound
Drug release
Kinetic model fitting
dc.title.none.fl_str_mv Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes
dc.type.none.fl_str_mv Peer-Reviewed
Published version
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Targeted liposomes triggered by ultrasound are a promising drug delivery system as they potentially improve the clinical outcomes of chemotherapy while reducing associated side effects. In this work, a comprehensive model fitting was performed for a large dataset of liposomal release profiles with seven targeting moieties (albumin, cRGD, estrone, hyaluronic acid, Herceptin, lactobionic acid, and transferrin) in addition to the control liposomes under ultrasound release protocols. Two levels of ultrasound frequencies were tested: low frequency (20 kHz) at 6.2, 9, and 10 mW/cm2 as well as high frequencies (1.07 MHz and 3 MHz) at 10.5 and 173 W/cm2. At a low frequency, Hixson–Crowell, Korsmeyer–Peppas, Gompertz, Weibull, and Lu–Hagen showed good fits to our release profiles at all three power densities. At high frequencies, the former three models reflected the best fit. These models will aid in predicting drug release profiles for future in vitro studies.
format article
id aus_cb01761a2b9f7d09d53ed51ba318859f
identifier_str_mv AlMajed, Z.; Salkho, N.M.; Sulieman, H.; Husseini, G.A. Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes. Biomedicines 2022, 10, 3139. https://doi.org/10.3390/biomedicines10123139
2227-9059
10.3390/biomedicines10123139
language_invalid_str_mv en_US
network_acronym_str aus
network_name_str aus
oai_identifier_str oai:repository.aus.edu:11073/25088
publishDate 2022
publisher.none.fl_str_mv MDPI
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted LiposomesAlmajed, Zeyad MohamedSalkho, NajlaSulieman, HanaHusseini, GhalebDrug delivery systemsCancer treatmentLiposomesLigand targetingUltrasoundDrug releaseKinetic model fittingTargeted liposomes triggered by ultrasound are a promising drug delivery system as they potentially improve the clinical outcomes of chemotherapy while reducing associated side effects. In this work, a comprehensive model fitting was performed for a large dataset of liposomal release profiles with seven targeting moieties (albumin, cRGD, estrone, hyaluronic acid, Herceptin, lactobionic acid, and transferrin) in addition to the control liposomes under ultrasound release protocols. Two levels of ultrasound frequencies were tested: low frequency (20 kHz) at 6.2, 9, and 10 mW/cm2 as well as high frequencies (1.07 MHz and 3 MHz) at 10.5 and 173 W/cm2. At a low frequency, Hixson–Crowell, Korsmeyer–Peppas, Gompertz, Weibull, and Lu–Hagen showed good fits to our release profiles at all three power densities. At high frequencies, the former three models reflected the best fit. These models will aid in predicting drug release profiles for future in vitro studies.Dana Gas Endowed Chair for Chemical EngineeringAmerican University of SharjahSheikh Hamdan Award for Medical SciencesFriends of Cancer PatientsMDPI2022-12-07T10:22:53Z2022-12-07T10:22:53Z2022-12-05Peer-ReviewedPublished versioninfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfAlMajed, Z.; Salkho, N.M.; Sulieman, H.; Husseini, G.A. Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes. Biomedicines 2022, 10, 3139. https://doi.org/10.3390/biomedicines101231392227-9059http://hdl.handle.net/11073/2508810.3390/biomedicines10123139en_UShttps://doi.org/10.3390/biomedicines10123139oai:repository.aus.edu:11073/250882024-08-22T12:05:46Z
spellingShingle Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes
Almajed, Zeyad Mohamed
Drug delivery systems
Cancer treatment
Liposomes
Ligand targeting
Ultrasound
Drug release
Kinetic model fitting
status_str publishedVersion
title Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes
title_full Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes
title_fullStr Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes
title_full_unstemmed Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes
title_short Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes
title_sort Modeling of the In Vitro Release Kinetics of Sonosensitive Targeted Liposomes
topic Drug delivery systems
Cancer treatment
Liposomes
Ligand targeting
Ultrasound
Drug release
Kinetic model fitting
url http://hdl.handle.net/11073/25088