Strengthening of Pre-Damaged Columns exposed to Fire using FRCM

A Master of Science thesis in Civil Engineering by Bashar Al-Momani entitled, “Strengthening of Pre-Damaged Columns exposed to Fire using FRCM”, submitted in November 2025. Thesis advisor is Dr. Farid Abed. Soft copy is available (Thesis, Completion Certificate, Approval Signatures, and AUS Archives...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Al-Momani, Bashar (author)
التنسيق: doctoralThesis
منشور في: 2025
الموضوعات:
الوصول للمادة أونلاين:https://hdl.handle.net/11073/32592
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1864513443332096000
author Al-Momani, Bashar
author_facet Al-Momani, Bashar
author_role author
dc.contributor.none.fl_str_mv Abed, Farid
dc.creator.none.fl_str_mv Al-Momani, Bashar
dc.date.none.fl_str_mv 2025-11
2026-01-15T07:55:00Z
2026-01-15T07:55:00Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv 35.232-2025.45
https://hdl.handle.net/11073/32592
dc.language.none.fl_str_mv en_US
dc.relation.none.fl_str_mv Master of Science in Civil Engineering (MSCE)
dc.subject.none.fl_str_mv Fire-damaged
Column
FRCM
Axial Performance
dc.title.none.fl_str_mv Strengthening of Pre-Damaged Columns exposed to Fire using FRCM
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/doctoralThesis
description A Master of Science thesis in Civil Engineering by Bashar Al-Momani entitled, “Strengthening of Pre-Damaged Columns exposed to Fire using FRCM”, submitted in November 2025. Thesis advisor is Dr. Farid Abed. Soft copy is available (Thesis, Completion Certificate, Approval Signatures, and AUS Archives Consent Form).
format doctoralThesis
id aus_d5afc6eae820707ca0ed78304a8a4c0e
identifier_str_mv 35.232-2025.45
language_invalid_str_mv en_US
network_acronym_str aus
network_name_str aus
oai_identifier_str oai:repository.aus.edu:11073/32592
publishDate 2025
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Strengthening of Pre-Damaged Columns exposed to Fire using FRCMAl-Momani, BasharFire-damagedColumnFRCMAxial PerformanceA Master of Science thesis in Civil Engineering by Bashar Al-Momani entitled, “Strengthening of Pre-Damaged Columns exposed to Fire using FRCM”, submitted in November 2025. Thesis advisor is Dr. Farid Abed. Soft copy is available (Thesis, Completion Certificate, Approval Signatures, and AUS Archives Consent Form).Fabric-Reinforced Cementitious Matrix (FRCM) systems have recently emerged as an effective method for strengthening and repairing concrete structures. This technology embeds textile reinforcement within an inorganic cementitious mortar, creating a durable composite. Unlike traditional epoxy-based Fiber-Reinforced Polymers (FRP), FRCM maintains structural integrity at significantly higher temperatures, offering notable advantages for fire-prone applications. This study evaluates the performance of poly-paraphenylene-benzobisoxazole (PBO)-FRCM as a retrofitting solution for fire damaged reinforced concrete (RC) short columns. Seven circular RC columns, each 1.2 meters tall and 200 mm in diameter with a 1.5% reinforcement ratio, were tested under axial compression. Two columns served as control samples and were not exposed to fire, while five columns were exposed to fire for 133 minutes in accordance with ASTM E119, then repaired with two layers of PBO-FRCM. Variables included concrete type as normal (NSC) or Ultra-high performance concrete (UHPC), pre-fire wrapping with FRCM or FRP, and the presence of a cement-based insulation system prior to fire exposure. The findings demonstrated that post-fire strengthening plays a significant role in restoring the original capacity of the tested normal concrete specimens. Repairing the fire-exposed column, which lacked both insulation and wrapping, recovered 68% of its axial capacity. Pre-fire FRCM strengthening combined with insulation improved the post-fire axial behavior to similar levels to that of the unwrapped control specimens, but the axial capacity remained about 17% lower than that of the unheated FRCM-wrapped control column. PBO-FRCM effectively improved the axial performance of the UHPC column, where its axial capacity was 183% higher than that of the unrepaired counterpart. However, relative to the nominal capacity predicted by ACI ITG-4.3R, the repaired column retained only 36.5% of the original capacity. Analytical predictions based on international codes closely aligned with experimental findings, yielding experimental-to-predicted capacity ratios of 1.13–1.30 for control columns and 1.17–1.50 for fire-exposed columns, reflecting uncertainties associated with modeling post-fire material degradation.College of EngineeringDepartment of Civil EngineeringMaster of Science in Civil Engineering (MSCE)Abed, Farid2026-01-15T07:55:00Z2026-01-15T07:55:00Z2025-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdf35.232-2025.45https://hdl.handle.net/11073/32592en_USMaster of Science in Civil Engineering (MSCE)oai:repository.aus.edu:11073/325922026-01-15T11:33:29Z
spellingShingle Strengthening of Pre-Damaged Columns exposed to Fire using FRCM
Al-Momani, Bashar
Fire-damaged
Column
FRCM
Axial Performance
status_str publishedVersion
title Strengthening of Pre-Damaged Columns exposed to Fire using FRCM
title_full Strengthening of Pre-Damaged Columns exposed to Fire using FRCM
title_fullStr Strengthening of Pre-Damaged Columns exposed to Fire using FRCM
title_full_unstemmed Strengthening of Pre-Damaged Columns exposed to Fire using FRCM
title_short Strengthening of Pre-Damaged Columns exposed to Fire using FRCM
title_sort Strengthening of Pre-Damaged Columns exposed to Fire using FRCM
topic Fire-damaged
Column
FRCM
Axial Performance
url https://hdl.handle.net/11073/32592