Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)

A Master of Science thesis in Civil Engineering by Nour Al Huda Haitham Tello entitled, “Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)”, submitted in May 2021. Thesis advisor is Dr. Farid Abed and thesis co-advisor is Dr. Tamer El Maaddawy. Soft copy is ava...

Full description

Saved in:
Bibliographic Details
Main Author: Tello, Noor Al Huda Haitham (author)
Format: doctoralThesis
Published: 2021
Subjects:
Online Access:http://hdl.handle.net/11073/21547
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1864513432884084736
author Tello, Noor Al Huda Haitham
author_facet Tello, Noor Al Huda Haitham
author_role author
dc.contributor.none.fl_str_mv Abed, Farid
El Maaddawy, Tamer
dc.creator.none.fl_str_mv Tello, Noor Al Huda Haitham
dc.date.none.fl_str_mv 2021-09-22T11:39:51Z
2021-09-22T11:39:51Z
2021-05
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv 35.232-2021.32
http://hdl.handle.net/11073/21547
dc.language.none.fl_str_mv en_US
dc.subject.none.fl_str_mv Reinforced concrete
RC columns
Short columns
FRCM
Fiber Reinforced Cementitious Matrix (FRCM)
PBO-FRCM
Concrete strengthening
Ultimate capacity
Ductility
dc.title.none.fl_str_mv Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/doctoralThesis
description A Master of Science thesis in Civil Engineering by Nour Al Huda Haitham Tello entitled, “Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)”, submitted in May 2021. Thesis advisor is Dr. Farid Abed and thesis co-advisor is Dr. Tamer El Maaddawy. Soft copy is available (Thesis, Completion Certificate, Approval Signatures, and AUS Archives Consent Form).
format doctoralThesis
id aus_da2450adbeb16557f229c4999829cebb
identifier_str_mv 35.232-2021.32
language_invalid_str_mv en_US
network_acronym_str aus
network_name_str aus
oai_identifier_str oai:repository.aus.edu:11073/21547
publishDate 2021
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)Tello, Noor Al Huda HaithamReinforced concreteRC columnsShort columnsFRCMFiber Reinforced Cementitious Matrix (FRCM)PBO-FRCMConcrete strengtheningUltimate capacityDuctilityA Master of Science thesis in Civil Engineering by Nour Al Huda Haitham Tello entitled, “Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)”, submitted in May 2021. Thesis advisor is Dr. Farid Abed and thesis co-advisor is Dr. Tamer El Maaddawy. Soft copy is available (Thesis, Completion Certificate, Approval Signatures, and AUS Archives Consent Form).A recently emerging technique to strengthen existing concrete structures using Fiber-Reinforced Cementitious Matrix (FRCM) is introduced to retrofit structural members. FRCM is an inorganic matrix that consists of textile layers sandwiched between cementitious mortar layers. The main objective of this study is to investigate the response of reinforced concrete (RC) short columns strengthened with poly-paraphenylene-ben-zobisoxazole (PBO) FRCM under pure axial compression. The aim is to study the effect of the column cross-section shape as well as the number of FRCM layers on the effectiveness of PBO-FRCM systems in improving the strength and ductility of pre-damaged and non-damaged RC columns. A total of 10 columns with a clear height of 800 mm and a longitudinal reinforcement ratio of 1.5% were cast and tested monotonically until failure. Also, columns were either unwrapped which served as controls, wrapped with 2 PBO-FRCM layers or wrapped with 4 PBO-FRCM layers. Experimental results showed that strengthening pre-damaged RC columns with PBO-FRCM is highly efficient in restoring and increasing the original capacity, where the capacity increased with the increase of number of PBO-FRCM layers. Circular columns showed a better improvement in ultimate capacity where the capacity increase ranged from 38 to 71%. Also, strengthening short RC columns with PBO-FRCM increased the column ductility with a range of 19 to 82%. Finally, theoretical ultimate capacities of strengthened columns calculated using the provisions of ACI 549.4R-13 code showed that the code is accurate at estimating the capacity of short RC columns strengthened with PBO-FRCM.College of EngineeringDepartment of Civil EngineeringMaster of Science in Civil Engineering (MSCE)Abed, FaridEl Maaddawy, Tamer2021-09-22T11:39:51Z2021-09-22T11:39:51Z2021-05info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdf35.232-2021.32http://hdl.handle.net/11073/21547en_USoai:repository.aus.edu:11073/215472025-06-26T12:22:33Z
spellingShingle Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)
Tello, Noor Al Huda Haitham
Reinforced concrete
RC columns
Short columns
FRCM
Fiber Reinforced Cementitious Matrix (FRCM)
PBO-FRCM
Concrete strengthening
Ultimate capacity
Ductility
status_str publishedVersion
title Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)
title_full Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)
title_fullStr Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)
title_full_unstemmed Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)
title_short Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)
title_sort Performance of RC Columns Strengthened with Fabric-Reinforced Cementitious Matrix (FRCM)
topic Reinforced concrete
RC columns
Short columns
FRCM
Fiber Reinforced Cementitious Matrix (FRCM)
PBO-FRCM
Concrete strengthening
Ultimate capacity
Ductility
url http://hdl.handle.net/11073/21547