Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE Office

Natural ventilation has been the main feature for maintaining thermal comfort in a space since ages. The research intends to merge the use of natural and artificial ventilation to create a comfortable thermal environment for the occupants of an office. It also helps to reduce the total energy consum...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Ajayan, Indu (author)
منشور في: 2015
الموضوعات:
الوصول للمادة أونلاين:http://bspace.buid.ac.ae/handle/1234/771
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1862980611628597248
author Ajayan, Indu
author_facet Ajayan, Indu
author_role author
dc.creator.none.fl_str_mv Ajayan, Indu
dc.date.none.fl_str_mv 2015-12-17T07:48:43Z
2015-12-17T07:48:43Z
2015-04
dc.identifier.none.fl_str_mv 120045
http://bspace.buid.ac.ae/handle/1234/771
dc.language.none.fl_str_mv en
dc.publisher.none.fl_str_mv The British University in Dubai (BUiD)
dc.subject.none.fl_str_mv thermal comfort
United Arab Emirates (UAE)
natural ventilation
energy consumption
dc.title.none.fl_str_mv Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE Office
dc.type.none.fl_str_mv Dissertation
description Natural ventilation has been the main feature for maintaining thermal comfort in a space since ages. The research intends to merge the use of natural and artificial ventilation to create a comfortable thermal environment for the occupants of an office. It also helps to reduce the total energy consumption of the building. Statistics suggest that UAE has been considered as one of the major per capita consumers of electricity and water, (Dubai Carbon, 2014). In order to reduce the total energy consumption, a strategy is formulated to use natural ventilation in office space with the use of operable windows. The study was conducted on a typical office building in Dubai, UAE. Integrated Environment Solutions (IES VE 2013) was used to analyze the various configurations on the virtual office created. The main factors that are taken into consideration in this system are the orientation of the opening, type of window, percentage opening of the window, the flow rate of the incoming air, the desired temperature of the occupant and the status of the external environment. An automation profile is created for ventilation so that it is available under the best suited weather conditions to reduce the use of air conditioners by making the interior thermally comfortable to the people. The total favorable hours is taken as the criteria of initial study. Based on these criteria specific cases were chosen to have the configuration for least energy consumption. The research concludes that a reduction of 35.49% in the annual energy consumption can be obtained from a combined ventilation systems. It is also noted that the major saving happens when there are more hours of favorable temperature which is the winter season. The temperature chosen by the occupant plays a major role in the energy reduction criteria. It was noticed that the major energy reduction is obtained by maintaining a proper set point temperature. The ventilation combined system also performs in a similar pattern at a lower level of energy consumption. The difference in the energy consumption between the two systems varies from 3% to 5%. The study concludes with the understanding that the ventilation pattern when incorporated into cooling system reduces the energy consumption but significant energy saving can be done using the right set point temperature. Also it can be noticed that the maximum saving occurs during the winter season.
id budr_05e924ef3581f63eee6c6d83b8d97aa3
identifier_str_mv 120045
language_invalid_str_mv en
network_acronym_str budr
network_name_str The British University in Dubai repository
oai_identifier_str oai:bspace.buid.ac.ae:1234/771
publishDate 2015
publisher.none.fl_str_mv The British University in Dubai (BUiD)
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE OfficeAjayan, Induthermal comfortUnited Arab Emirates (UAE)natural ventilationenergy consumptionNatural ventilation has been the main feature for maintaining thermal comfort in a space since ages. The research intends to merge the use of natural and artificial ventilation to create a comfortable thermal environment for the occupants of an office. It also helps to reduce the total energy consumption of the building. Statistics suggest that UAE has been considered as one of the major per capita consumers of electricity and water, (Dubai Carbon, 2014). In order to reduce the total energy consumption, a strategy is formulated to use natural ventilation in office space with the use of operable windows. The study was conducted on a typical office building in Dubai, UAE. Integrated Environment Solutions (IES VE 2013) was used to analyze the various configurations on the virtual office created. The main factors that are taken into consideration in this system are the orientation of the opening, type of window, percentage opening of the window, the flow rate of the incoming air, the desired temperature of the occupant and the status of the external environment. An automation profile is created for ventilation so that it is available under the best suited weather conditions to reduce the use of air conditioners by making the interior thermally comfortable to the people. The total favorable hours is taken as the criteria of initial study. Based on these criteria specific cases were chosen to have the configuration for least energy consumption. The research concludes that a reduction of 35.49% in the annual energy consumption can be obtained from a combined ventilation systems. It is also noted that the major saving happens when there are more hours of favorable temperature which is the winter season. The temperature chosen by the occupant plays a major role in the energy reduction criteria. It was noticed that the major energy reduction is obtained by maintaining a proper set point temperature. The ventilation combined system also performs in a similar pattern at a lower level of energy consumption. The difference in the energy consumption between the two systems varies from 3% to 5%. The study concludes with the understanding that the ventilation pattern when incorporated into cooling system reduces the energy consumption but significant energy saving can be done using the right set point temperature. Also it can be noticed that the maximum saving occurs during the winter season.The British University in Dubai (BUiD)2015-12-17T07:48:43Z2015-12-17T07:48:43Z2015-04Dissertation120045http://bspace.buid.ac.ae/handle/1234/771enoai:bspace.buid.ac.ae:1234/7712016-06-23T11:03:26Z
spellingShingle Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE Office
Ajayan, Indu
thermal comfort
United Arab Emirates (UAE)
natural ventilation
energy consumption
title Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE Office
title_full Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE Office
title_fullStr Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE Office
title_full_unstemmed Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE Office
title_short Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE Office
title_sort Impact of Ventilation on the Thermal Comfort by Operable Window in a Typical UAE Office
topic thermal comfort
United Arab Emirates (UAE)
natural ventilation
energy consumption
url http://bspace.buid.ac.ae/handle/1234/771