Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configuration

Buildings’ retrofit has been evolving throughout the past decades worldwide, aiming to improve the overall efficiency of the buildings and its operations, and many owners on private and public sectors are looking for highly effective systems and systems’ components to operate and manage their buildi...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: MAHMOUD, ABDALLAH (author)
منشور في: 2021
الموضوعات:
الوصول للمادة أونلاين:https://bspace.buid.ac.ae/handle/1234/1962
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1862980610537029632
author MAHMOUD, ABDALLAH
author_facet MAHMOUD, ABDALLAH
author_role author
dc.creator.none.fl_str_mv MAHMOUD, ABDALLAH
dc.date.none.fl_str_mv 2021-08
2022-02-09T13:08:34Z
2022-02-09T13:08:34Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv 20180730
https://bspace.buid.ac.ae/handle/1234/1962
dc.language.none.fl_str_mv en
dc.publisher.none.fl_str_mv The British University in Dubai (BUiD)
dc.subject.none.fl_str_mv energy retrofit
United Arab Emirates (UAE)
chilled water risers
chilled water pumps
dc.title.none.fl_str_mv Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configuration
dc.type.none.fl_str_mv Dissertation
description Buildings’ retrofit has been evolving throughout the past decades worldwide, aiming to improve the overall efficiency of the buildings and its operations, and many owners on private and public sectors are looking for highly effective systems and systems’ components to operate and manage their building stock due to the excessive energy consumption, thermal comfort, indoor air quality and hygienic requirements. This research is going to provide practical insights in building technologies, what multiple attempts have been evolving to improve HVAC systems, either from the effectiveness of heating and cooling distribution systems designs and retrofits or from the system components and operational strategies and techniques, particularly on the chilled water loops’ configuration retrofit and temperature difference “ΔT”. Such retrofit debates have been going into many experimental methods, on-premises’ solutions, new technologies, and multiple techniques of operations, and many guidelines have been published and shared for the sake of continuous improvement of chilled water systems and the optimum ways of operations and to clear those doubts surrounding those kinds of debates, this dissertation is verifying couple of those retrofit measures. With that being said, this research aims to provide reliable information and outputs on the best practice of operating chilled water network for a UAE-based building by converting the constant primary network to a variable one in addition to solve permanently the building ΔT issues by replacing the conventional pressure dependent control valves and adding intelligent valves on the main risers and the main airside equipment for this selected building, aiming to be quite practical as could as possible and have the outcome of combining both measures together, accordingly, the results show a potential energy saving on the range of 14-21% on the conservative side by applying the suggested retrofit measures, which leads to approximately an energy cost of savings of at least half a million to seven hundred thousands of UAE dirhams along with simple payback of 3-4 years which is considered an attractive SPB period for investors on such fields. Such energy cost savings is derived as a result of the significant reduction on pumping capacity in addition to insignificant but noticeable reduction on the lift of the air-cooled chillers’ compressors. Additionally, the research tries to present to buildings’ retrofit community a methodology to be followed for any future attempts on the same field by utilizing computer-based modeling software “IESVE” to simulate the existing cases and compare multiple scenarios for chilled water loops and ΔT. As a result of this research, it is made proven to any debates that retrofitting a typical UAE building by converting constant primary pumps into variable loop in addition to limiting the ΔT between 6 to 9oC on the risers side should lead to a magnificent energy cost saving.
id budr_37853a9b6aab101339c4e54cfe2446a6
identifier_str_mv 20180730
language_invalid_str_mv en
network_acronym_str budr
network_name_str The British University in Dubai repository
oai_identifier_str oai:bspace.buid.ac.ae:1234/1962
publishDate 2021
publisher.none.fl_str_mv The British University in Dubai (BUiD)
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configurationMAHMOUD, ABDALLAHenergy retrofitUnited Arab Emirates (UAE)chilled water riserschilled water pumpsBuildings’ retrofit has been evolving throughout the past decades worldwide, aiming to improve the overall efficiency of the buildings and its operations, and many owners on private and public sectors are looking for highly effective systems and systems’ components to operate and manage their building stock due to the excessive energy consumption, thermal comfort, indoor air quality and hygienic requirements. This research is going to provide practical insights in building technologies, what multiple attempts have been evolving to improve HVAC systems, either from the effectiveness of heating and cooling distribution systems designs and retrofits or from the system components and operational strategies and techniques, particularly on the chilled water loops’ configuration retrofit and temperature difference “ΔT”. Such retrofit debates have been going into many experimental methods, on-premises’ solutions, new technologies, and multiple techniques of operations, and many guidelines have been published and shared for the sake of continuous improvement of chilled water systems and the optimum ways of operations and to clear those doubts surrounding those kinds of debates, this dissertation is verifying couple of those retrofit measures. With that being said, this research aims to provide reliable information and outputs on the best practice of operating chilled water network for a UAE-based building by converting the constant primary network to a variable one in addition to solve permanently the building ΔT issues by replacing the conventional pressure dependent control valves and adding intelligent valves on the main risers and the main airside equipment for this selected building, aiming to be quite practical as could as possible and have the outcome of combining both measures together, accordingly, the results show a potential energy saving on the range of 14-21% on the conservative side by applying the suggested retrofit measures, which leads to approximately an energy cost of savings of at least half a million to seven hundred thousands of UAE dirhams along with simple payback of 3-4 years which is considered an attractive SPB period for investors on such fields. Such energy cost savings is derived as a result of the significant reduction on pumping capacity in addition to insignificant but noticeable reduction on the lift of the air-cooled chillers’ compressors. Additionally, the research tries to present to buildings’ retrofit community a methodology to be followed for any future attempts on the same field by utilizing computer-based modeling software “IESVE” to simulate the existing cases and compare multiple scenarios for chilled water loops and ΔT. As a result of this research, it is made proven to any debates that retrofitting a typical UAE building by converting constant primary pumps into variable loop in addition to limiting the ΔT between 6 to 9oC on the risers side should lead to a magnificent energy cost saving.The British University in Dubai (BUiD)2022-02-09T13:08:34Z2022-02-09T13:08:34Z2021-08Dissertationapplication/pdf20180730https://bspace.buid.ac.ae/handle/1234/1962enoai:bspace.buid.ac.ae:1234/19622024-05-20T23:00:17Z
spellingShingle Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configuration
MAHMOUD, ABDALLAH
energy retrofit
United Arab Emirates (UAE)
chilled water risers
chilled water pumps
title Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configuration
title_full Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configuration
title_fullStr Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configuration
title_full_unstemmed Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configuration
title_short Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configuration
title_sort Studying the impact of an energy retrofit of a UAE-based existing building by adding intelligent valves on the main chilled water risers and reconfigure the chilled water pumps to be on variable water flow loop configuration
topic energy retrofit
United Arab Emirates (UAE)
chilled water risers
chilled water pumps
url https://bspace.buid.ac.ae/handle/1234/1962