Sensitivity analysis of work plane illuminance to room surface reflectance values

Nowadays, the employees spend around 8 to 10 hours a day in their offices , therefore, the creating of right work environment is an essential matter in today’s designs for offices. However , some people till today don’t know how could the lighting influences the workers at the offices . In this stud...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: WAFI, RANA BASHIR (author)
منشور في: 2018
الموضوعات:
الوصول للمادة أونلاين:https://bspace.buid.ac.ae/handle/1234/1497
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1862980618149691393
author WAFI, RANA BASHIR
author_facet WAFI, RANA BASHIR
author_role author
dc.creator.none.fl_str_mv WAFI, RANA BASHIR
dc.date.none.fl_str_mv 2018-11
2019-10-30T06:08:17Z
2019-10-30T06:08:17Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv 2015317033
https://bspace.buid.ac.ae/handle/1234/1497
dc.language.none.fl_str_mv en
dc.publisher.none.fl_str_mv The British University in Dubai (BUiD)
dc.subject.none.fl_str_mv sensitivity analysis
illuminance
room surface
work environment
surface reflectance
dc.title.none.fl_str_mv Sensitivity analysis of work plane illuminance to room surface reflectance values
dc.type.none.fl_str_mv Dissertation
description Nowadays, the employees spend around 8 to 10 hours a day in their offices , therefore, the creating of right work environment is an essential matter in today’s designs for offices. However , some people till today don’t know how could the lighting influences the workers at the offices . In this study , the researcher has explored the effects and impacts of one parameter which is the ‘surface reflectance’ in interior spaces as walls , ceiling and floor , on the illuminance level that is visible on the work plane by employees . For the purpose of proving it , two digital models were created in this study in order to run the simulations. Significantly, the small area office illuminance increased with high values when the wall surface reflectance is high . In the large open spaces , and when the ceiling surface reflectance is high , the illumination will be increased more than results of increasing wall reflectance values . In this study , the researcher addressed the effects of the wall reflectance through a variety of simulations for the reflectance’s of ceiling , walls and floor , to demonstrate the effects of the surface reflectance on increasing the space illumination , which can play a role as an energy saving as well as cost saving while the high demand of lighting is needed .
id budr_81dfd9f4acc74299de7501a4e29d1981
identifier_str_mv 2015317033
language_invalid_str_mv en
network_acronym_str budr
network_name_str The British University in Dubai repository
oai_identifier_str oai:bspace.buid.ac.ae:1234/1497
publishDate 2018
publisher.none.fl_str_mv The British University in Dubai (BUiD)
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Sensitivity analysis of work plane illuminance to room surface reflectance valuesWAFI, RANA BASHIRsensitivity analysisilluminanceroom surfacework environmentsurface reflectanceNowadays, the employees spend around 8 to 10 hours a day in their offices , therefore, the creating of right work environment is an essential matter in today’s designs for offices. However , some people till today don’t know how could the lighting influences the workers at the offices . In this study , the researcher has explored the effects and impacts of one parameter which is the ‘surface reflectance’ in interior spaces as walls , ceiling and floor , on the illuminance level that is visible on the work plane by employees . For the purpose of proving it , two digital models were created in this study in order to run the simulations. Significantly, the small area office illuminance increased with high values when the wall surface reflectance is high . In the large open spaces , and when the ceiling surface reflectance is high , the illumination will be increased more than results of increasing wall reflectance values . In this study , the researcher addressed the effects of the wall reflectance through a variety of simulations for the reflectance’s of ceiling , walls and floor , to demonstrate the effects of the surface reflectance on increasing the space illumination , which can play a role as an energy saving as well as cost saving while the high demand of lighting is needed .The British University in Dubai (BUiD)2019-10-30T06:08:17Z2019-10-30T06:08:17Z2018-11Dissertationapplication/pdf2015317033https://bspace.buid.ac.ae/handle/1234/1497enoai:bspace.buid.ac.ae:1234/14972019-10-30T23:00:55Z
spellingShingle Sensitivity analysis of work plane illuminance to room surface reflectance values
WAFI, RANA BASHIR
sensitivity analysis
illuminance
room surface
work environment
surface reflectance
title Sensitivity analysis of work plane illuminance to room surface reflectance values
title_full Sensitivity analysis of work plane illuminance to room surface reflectance values
title_fullStr Sensitivity analysis of work plane illuminance to room surface reflectance values
title_full_unstemmed Sensitivity analysis of work plane illuminance to room surface reflectance values
title_short Sensitivity analysis of work plane illuminance to room surface reflectance values
title_sort Sensitivity analysis of work plane illuminance to room surface reflectance values
topic sensitivity analysis
illuminance
room surface
work environment
surface reflectance
url https://bspace.buid.ac.ae/handle/1234/1497