Electrical Power Transformer Health Condition Assessment Using Health Index Model

Power Transformer is the principal to preserve Transmission network operation and is required to ensure the stability of the power grid. Over time, Power Transformer is degrading, and it is essential to assess its condition to avoid system interruptions and breakdowns. Moreover, condition evaluation...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: ALASHI, LUBNA (author)
منشور في: 2023
الموضوعات:
الوصول للمادة أونلاين:https://bspace.buid.ac.ae/handle/1234/2464
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1862980614192365568
author ALASHI, LUBNA
author_facet ALASHI, LUBNA
author_role author
dc.contributor.none.fl_str_mv Professor Alaa A-Ameer
dc.creator.none.fl_str_mv ALASHI, LUBNA
dc.date.none.fl_str_mv 2023-12-07T08:48:02Z
2023-12-07T08:48:02Z
2023-06
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv 20206322
https://bspace.buid.ac.ae/handle/1234/2464
dc.language.none.fl_str_mv en
dc.publisher.none.fl_str_mv The British University in Dubai (BUiD)
dc.subject.none.fl_str_mv electric power transformer, health condition assessment, Middle East
dc.title.none.fl_str_mv Electrical Power Transformer Health Condition Assessment Using Health Index Model
dc.type.none.fl_str_mv Dissertation
description Power Transformer is the principal to preserve Transmission network operation and is required to ensure the stability of the power grid. Over time, Power Transformer is degrading, and it is essential to assess its condition to avoid system interruptions and breakdowns. Moreover, condition evaluation may help to regularly revise and adjust the maintenance strategy to effectively optimize the recourses used with respect to the desired quality. Health Index formulation is one of the effective models to evaluate the asset condition. It comprises a series of evaluation parameters combined into a single value to indicate the health index from different aspects for the best asset management planning. This study aims to develop a Health Index model for Power Transformers based on the most suitable parameters. Furthermore, the research will propose a decision-making Flow Chart for the maintenance requirements and determining the remaining life. The major parameters selected in this research are electrical and laboratory tests, location, age, and site observations. Basically, the existing methods of Health Index are usually a combination of experts’ knowledge and data-driven. Therefore, the method used in this research is the scoring and weighting method to evaluate the parameters using experts’ experience, international standards, and previous studies. The data is collected based on a real case study of Three Power Transformers in the Middle East region. Further, a Flow Chart diagram is established to make a decision on the most appropriate maintenance requirement needed for each Power Transformer. After that, the remaining expected life is also determined. The findings of the Three Power Transformers states are Good, close to Fair, and close to Poor. Accordingly, further enhancement is required for the two Power Transformers by adjusting the maintenance plan and continuously monitoring their condition. A replacement plan should also be prepared as both Power Transformers' end of life are less than Ten years. In conclusion, the key factor in establishing a successful Health Index model is selecting realistic and suitable parameters, scores and weight.
id budr_9dbc76432878c0f3d63f74be944be96e
identifier_str_mv 20206322
language_invalid_str_mv en
network_acronym_str budr
network_name_str The British University in Dubai repository
oai_identifier_str oai:bspace.buid.ac.ae:1234/2464
publishDate 2023
publisher.none.fl_str_mv The British University in Dubai (BUiD)
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Electrical Power Transformer Health Condition Assessment Using Health Index ModelALASHI, LUBNAelectric power transformer, health condition assessment, Middle EastPower Transformer is the principal to preserve Transmission network operation and is required to ensure the stability of the power grid. Over time, Power Transformer is degrading, and it is essential to assess its condition to avoid system interruptions and breakdowns. Moreover, condition evaluation may help to regularly revise and adjust the maintenance strategy to effectively optimize the recourses used with respect to the desired quality. Health Index formulation is one of the effective models to evaluate the asset condition. It comprises a series of evaluation parameters combined into a single value to indicate the health index from different aspects for the best asset management planning. This study aims to develop a Health Index model for Power Transformers based on the most suitable parameters. Furthermore, the research will propose a decision-making Flow Chart for the maintenance requirements and determining the remaining life. The major parameters selected in this research are electrical and laboratory tests, location, age, and site observations. Basically, the existing methods of Health Index are usually a combination of experts’ knowledge and data-driven. Therefore, the method used in this research is the scoring and weighting method to evaluate the parameters using experts’ experience, international standards, and previous studies. The data is collected based on a real case study of Three Power Transformers in the Middle East region. Further, a Flow Chart diagram is established to make a decision on the most appropriate maintenance requirement needed for each Power Transformer. After that, the remaining expected life is also determined. The findings of the Three Power Transformers states are Good, close to Fair, and close to Poor. Accordingly, further enhancement is required for the two Power Transformers by adjusting the maintenance plan and continuously monitoring their condition. A replacement plan should also be prepared as both Power Transformers' end of life are less than Ten years. In conclusion, the key factor in establishing a successful Health Index model is selecting realistic and suitable parameters, scores and weight.The British University in Dubai (BUiD)Professor Alaa A-Ameer2023-12-07T08:48:02Z2023-12-07T08:48:02Z2023-06Dissertationapplication/pdf20206322https://bspace.buid.ac.ae/handle/1234/2464enoai:bspace.buid.ac.ae:1234/24642023-12-07T23:00:41Z
spellingShingle Electrical Power Transformer Health Condition Assessment Using Health Index Model
ALASHI, LUBNA
electric power transformer, health condition assessment, Middle East
title Electrical Power Transformer Health Condition Assessment Using Health Index Model
title_full Electrical Power Transformer Health Condition Assessment Using Health Index Model
title_fullStr Electrical Power Transformer Health Condition Assessment Using Health Index Model
title_full_unstemmed Electrical Power Transformer Health Condition Assessment Using Health Index Model