Potential of horizontal louvers in increased energy savings in a commercial building in Dubai

Building façade contributes to a major share of energy expenditure in residential as well as commercial buildings. There is a need to look for alternate options of façade design, in order to replace the glazing option contributing to greenhouse gases and global warming. This dissertation investigate...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: BORDAWEKAR, SANIYA (author)
منشور في: 2018
الموضوعات:
الوصول للمادة أونلاين:https://bspace.buid.ac.ae/handle/1234/1404
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1862980619379671040
author BORDAWEKAR, SANIYA
author_facet BORDAWEKAR, SANIYA
author_role author
dc.creator.none.fl_str_mv BORDAWEKAR, SANIYA
dc.date.none.fl_str_mv 2018-10
2019-05-07T08:21:53Z
2019-05-07T08:21:53Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv 2015217038
https://bspace.buid.ac.ae/handle/1234/1404
dc.language.none.fl_str_mv en
dc.publisher.none.fl_str_mv The British University in Dubai (BUiD)
dc.subject.none.fl_str_mv horizontal louvers
energy efficiency
commercial building
United Arab Emirates (UAE)
Building facade
dc.title.none.fl_str_mv Potential of horizontal louvers in increased energy savings in a commercial building in Dubai
dc.type.none.fl_str_mv Dissertation
description Building façade contributes to a major share of energy expenditure in residential as well as commercial buildings. There is a need to look for alternate options of façade design, in order to replace the glazing option contributing to greenhouse gases and global warming. This dissertation investigates the use of horizontal louvers in increasing the energy efficiency of an office cabin in Dubai, facing south direction. The base case is simulated for further comparative simulations. Fixed and variable parameters of the simulation are investigated and simulation matrix is made for 1) Variation in Angle, 2) Variation in Width, 3) Variation in CC, 4) Variation in PV types. Each parameter is simulated with its variable options, and results are tabulated. The configuration for louvers with and without PV cells are noted separately. The artificial lighting in the cabin is linked to the dimmer sensors to a configuration that the lights will dim to 0.4% its original power if the lux level in the room is more than 500 Lux. Effect of dimmer sensor on and off is investigated in each simulation. The dissertation creates a correlation link between the simulation results and changes in parameters. Dimmer sensor configuration shows about 10-15 % increase in energy savings than the configuration with sensor off. The most efficient case is the configuration of 50 degree louver angle, 90mm width, 90mm center to center and mono crystalline PV cells. Comparative analysis of 90mm and 150mm dimensions for both louver width and CC, highlights that if the dimensions of the two are equal, energy savings in more. This is because the louver dimensions give an optimum solution for shading profile of the horizontal louvers used on south direction. Efficient case shows 28% more savings than base case for louvers without PV, and 40% more savings for louvers with PV. Economic case is also configured, which gives the best possible solution considering the justification of cost for the efficient case. This case configures thin film type of PV cells and shows a result of 27.88% and 34.92% more savings than base case for louvers without and with PV respectively. Payback period for efficient and economic case is 18 years and 12 years respectively. The result highlights that using the dimmer sensors can considerably add to energy efficiency in the most economical way. After this, the priority can be given to change in optimum configuration of louver parameters. Integration of photovoltaic cells is the last option to be recommended. The payback period of this is considerably more due to the highly subsidized rates of electricity tariff in UAE. The dissertation creates a benchmark for horizontal louver configuration and its role in increasing the energy savings. This can be used as a module to recreate horizontal louvered façade on the whole building and create an impact in reducing energy expenditure of office buildings in Dubai.
id budr_b176cd6871cfdc7769cac9018def94cc
identifier_str_mv 2015217038
language_invalid_str_mv en
network_acronym_str budr
network_name_str The British University in Dubai repository
oai_identifier_str oai:bspace.buid.ac.ae:1234/1404
publishDate 2018
publisher.none.fl_str_mv The British University in Dubai (BUiD)
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Potential of horizontal louvers in increased energy savings in a commercial building in DubaiBORDAWEKAR, SANIYAhorizontal louversenergy efficiencycommercial buildingUnited Arab Emirates (UAE)Building facadeBuilding façade contributes to a major share of energy expenditure in residential as well as commercial buildings. There is a need to look for alternate options of façade design, in order to replace the glazing option contributing to greenhouse gases and global warming. This dissertation investigates the use of horizontal louvers in increasing the energy efficiency of an office cabin in Dubai, facing south direction. The base case is simulated for further comparative simulations. Fixed and variable parameters of the simulation are investigated and simulation matrix is made for 1) Variation in Angle, 2) Variation in Width, 3) Variation in CC, 4) Variation in PV types. Each parameter is simulated with its variable options, and results are tabulated. The configuration for louvers with and without PV cells are noted separately. The artificial lighting in the cabin is linked to the dimmer sensors to a configuration that the lights will dim to 0.4% its original power if the lux level in the room is more than 500 Lux. Effect of dimmer sensor on and off is investigated in each simulation. The dissertation creates a correlation link between the simulation results and changes in parameters. Dimmer sensor configuration shows about 10-15 % increase in energy savings than the configuration with sensor off. The most efficient case is the configuration of 50 degree louver angle, 90mm width, 90mm center to center and mono crystalline PV cells. Comparative analysis of 90mm and 150mm dimensions for both louver width and CC, highlights that if the dimensions of the two are equal, energy savings in more. This is because the louver dimensions give an optimum solution for shading profile of the horizontal louvers used on south direction. Efficient case shows 28% more savings than base case for louvers without PV, and 40% more savings for louvers with PV. Economic case is also configured, which gives the best possible solution considering the justification of cost for the efficient case. This case configures thin film type of PV cells and shows a result of 27.88% and 34.92% more savings than base case for louvers without and with PV respectively. Payback period for efficient and economic case is 18 years and 12 years respectively. The result highlights that using the dimmer sensors can considerably add to energy efficiency in the most economical way. After this, the priority can be given to change in optimum configuration of louver parameters. Integration of photovoltaic cells is the last option to be recommended. The payback period of this is considerably more due to the highly subsidized rates of electricity tariff in UAE. The dissertation creates a benchmark for horizontal louver configuration and its role in increasing the energy savings. This can be used as a module to recreate horizontal louvered façade on the whole building and create an impact in reducing energy expenditure of office buildings in Dubai.The British University in Dubai (BUiD)2019-05-07T08:21:53Z2019-05-07T08:21:53Z2018-10Dissertationapplication/pdf2015217038https://bspace.buid.ac.ae/handle/1234/1404enoai:bspace.buid.ac.ae:1234/14042021-09-23T11:27:15Z
spellingShingle Potential of horizontal louvers in increased energy savings in a commercial building in Dubai
BORDAWEKAR, SANIYA
horizontal louvers
energy efficiency
commercial building
United Arab Emirates (UAE)
Building facade
title Potential of horizontal louvers in increased energy savings in a commercial building in Dubai
title_full Potential of horizontal louvers in increased energy savings in a commercial building in Dubai
title_fullStr Potential of horizontal louvers in increased energy savings in a commercial building in Dubai
title_full_unstemmed Potential of horizontal louvers in increased energy savings in a commercial building in Dubai
title_short Potential of horizontal louvers in increased energy savings in a commercial building in Dubai
title_sort Potential of horizontal louvers in increased energy savings in a commercial building in Dubai
topic horizontal louvers
energy efficiency
commercial building
United Arab Emirates (UAE)
Building facade
url https://bspace.buid.ac.ae/handle/1234/1404