Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal Comfort

This research is an evaluation of the effectiveness of wind catchers as means of providing thermal comfort for modern residential buildings in the hot arid climates in the UAE. Though this research involves a residence in Abu Dhabi as a case study, it stresses that the results obtained can be used f...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Riza, Raashid (author)
منشور في: 2014
الموضوعات:
الوصول للمادة أونلاين:http://bspace.buid.ac.ae/handle/1234/732
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1862980616438415360
author Riza, Raashid
author_facet Riza, Raashid
author_role author
dc.creator.none.fl_str_mv Riza, Raashid
dc.date.none.fl_str_mv 2014-04
2015-08-24T06:07:19Z
2015-08-24T06:07:19Z
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.identifier.none.fl_str_mv 110107
http://bspace.buid.ac.ae/handle/1234/732
dc.language.none.fl_str_mv en
dc.publisher.none.fl_str_mv The British University in Dubai (BUiD)
dc.subject.none.fl_str_mv wind catchers
modern residential buildings
thermal comfort
United Arab Emirates (UAE)
dc.title.none.fl_str_mv Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal Comfort
dc.type.none.fl_str_mv Dissertation
description This research is an evaluation of the effectiveness of wind catchers as means of providing thermal comfort for modern residential buildings in the hot arid climates in the UAE. Though this research involves a residence in Abu Dhabi as a case study, it stresses that the results obtained can be used for other regions with similar climates and in most instances are largely applicable. A computer simulation tool, IES VE 2013, is used as a methodology to model spaces and different configurations that consist of the following parameters, are tested: floor to ceiling height of the space, area of the window opening, height of the wind tower, orientation of the wind tower, percentage opening of the window and the percentage opening of the wind tower opening. An automatic condition profile is imposed on the window and wind tower openings by the software so that they open and function only when these conditions are satisfied. The study initially reviewed literature already existing on the integration of traditional sustainable techniques in the UAE. Further studies were done on how integral wind catchers were in traditional architecture to provide cooling for occupants in residences. The simulations were carried out in two steps. As a first step, the case study building as it exists was subjected to a thermal simulation analysis. Results were obtained in terms of annual hours within the human thermal comfort range and Degree Discomfort Hours (DDH). The second step involved carrying out a series of simulations according to a test matrix, results obtained were analysed in comparison to the existing case. Of the configurations tested, the optimal configuration bore the following characteristics: Floor to Ceiling Height of 6m, wind tower height of 9m with North West orientation, window area of 3 m2, wind tower opening of 2 m2, Percentage window opening of 100% and a percentage of wind tower opening 100%. The optimal configuration when tested resulted in 47.1% decrease in degree discomfort hours and a 22.1% increase of hours annually in the thermal comfort range when compared to the existing case. Furthermore, when the existing case was re-simulated with a cooling device switched on, it was estimated that the existing case consumes 39.5% more energy than the optimal configuration. The study concludes by identifying guidelines for the implementation and use of wind towers in the modern age and with recommendations for future research.
id budr_e055e403feeaa0ec36fec579dba83990
identifier_str_mv 110107
language_invalid_str_mv en
network_acronym_str budr
network_name_str The British University in Dubai repository
oai_identifier_str oai:bspace.buid.ac.ae:1234/732
publishDate 2014
publisher.none.fl_str_mv The British University in Dubai (BUiD)
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
spelling Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal ComfortRiza, Raashidwind catchersmodern residential buildingsthermal comfortUnited Arab Emirates (UAE)This research is an evaluation of the effectiveness of wind catchers as means of providing thermal comfort for modern residential buildings in the hot arid climates in the UAE. Though this research involves a residence in Abu Dhabi as a case study, it stresses that the results obtained can be used for other regions with similar climates and in most instances are largely applicable. A computer simulation tool, IES VE 2013, is used as a methodology to model spaces and different configurations that consist of the following parameters, are tested: floor to ceiling height of the space, area of the window opening, height of the wind tower, orientation of the wind tower, percentage opening of the window and the percentage opening of the wind tower opening. An automatic condition profile is imposed on the window and wind tower openings by the software so that they open and function only when these conditions are satisfied. The study initially reviewed literature already existing on the integration of traditional sustainable techniques in the UAE. Further studies were done on how integral wind catchers were in traditional architecture to provide cooling for occupants in residences. The simulations were carried out in two steps. As a first step, the case study building as it exists was subjected to a thermal simulation analysis. Results were obtained in terms of annual hours within the human thermal comfort range and Degree Discomfort Hours (DDH). The second step involved carrying out a series of simulations according to a test matrix, results obtained were analysed in comparison to the existing case. Of the configurations tested, the optimal configuration bore the following characteristics: Floor to Ceiling Height of 6m, wind tower height of 9m with North West orientation, window area of 3 m2, wind tower opening of 2 m2, Percentage window opening of 100% and a percentage of wind tower opening 100%. The optimal configuration when tested resulted in 47.1% decrease in degree discomfort hours and a 22.1% increase of hours annually in the thermal comfort range when compared to the existing case. Furthermore, when the existing case was re-simulated with a cooling device switched on, it was estimated that the existing case consumes 39.5% more energy than the optimal configuration. The study concludes by identifying guidelines for the implementation and use of wind towers in the modern age and with recommendations for future research.The British University in Dubai (BUiD)2015-08-24T06:07:19Z2015-08-24T06:07:19Z2014-04Dissertationapplication/pdfapplication/pdfapplication/pdf110107http://bspace.buid.ac.ae/handle/1234/732enoai:bspace.buid.ac.ae:1234/7322021-10-20T13:43:29Z
spellingShingle Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal Comfort
Riza, Raashid
wind catchers
modern residential buildings
thermal comfort
United Arab Emirates (UAE)
title Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal Comfort
title_full Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal Comfort
title_fullStr Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal Comfort
title_full_unstemmed Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal Comfort
title_short Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal Comfort
title_sort Integration of Wind Catchers in Modern Residential Buildings in the UAE as a Means of Providing Thermal Comfort
topic wind catchers
modern residential buildings
thermal comfort
United Arab Emirates (UAE)
url http://bspace.buid.ac.ae/handle/1234/732