Failure Modes Effects and Criticality Analysis and Fault Tree Analysis Case Study of Waste Heat Recovery Plant in a Cement Factory, United Arab Emirates
This article reports a case study of the appli cation of FMECA and FTA methods to inform the design of effective maintenance program for a waste heat recovery power plant in the hot arid climate of the United Arab Emirates. It illustrates the strengths and weaknesses of these approaches through a ca...
محفوظ في:
| المؤلف الرئيسي: | |
|---|---|
| مؤلفون آخرون: | , |
| منشور في: |
2020
|
| الوصول للمادة أونلاين: | https://bspace.buid.ac.ae/handle/1234/3261 |
| الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
| الملخص: | This article reports a case study of the appli cation of FMECA and FTA methods to inform the design of effective maintenance program for a waste heat recovery power plant in the hot arid climate of the United Arab Emirates. It illustrates the strengths and weaknesses of these approaches through a case study report of a live plant in a cement factory. The article highlights the implications and importance of plant-specific contextual factors in conducting quality FMECA and FTA. |
|---|