Failure Modes Effects and Criticality Analysis and Fault Tree Analysis Case Study of Waste Heat Recovery Plant in a Cement Factory, United Arab Emirates

This article reports a case study of the appli cation of FMECA and FTA methods to inform the design of effective maintenance program for a waste heat recovery power plant in the hot arid climate of the United Arab Emirates. It illustrates the strengths and weaknesses of these approaches through a ca...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Shanks, Kirk (author)
مؤلفون آخرون: Hamad, Abdallah (author), Ameer, Alaa (author)
منشور في: 2020
الوصول للمادة أونلاين:https://bspace.buid.ac.ae/handle/1234/3261
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
الوصف
الملخص:This article reports a case study of the appli cation of FMECA and FTA methods to inform the design of effective maintenance program for a waste heat recovery power plant in the hot arid climate of the United Arab Emirates. It illustrates the strengths and weaknesses of these approaches through a case study report of a live plant in a cement factory. The article highlights the implications and importance of plant-specific contextual factors in conducting quality FMECA and FTA.