Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions

Renewable energy sources have immense potential for enhancing environmental sustainability; however, addressing their intermittency and irregularity is vital for optimizing economic benefits within microgrids. Integrating renewable energy systems with energy storage presents a promising solution. Th...

Full description

Saved in:
Bibliographic Details
Main Author: Aya, Amer (author)
Other Authors: Massoud, Ahmed (author), Shaban, Khaled (author)
Format: article
Published: 2024
Subjects:
Online Access:http://dx.doi.org/10.1016/j.heliyon.2024.e27021
https://www.sciencedirect.com/science/article/pii/S2405844024030524
http://hdl.handle.net/10576/60184
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1857415084449464320
author Aya, Amer
author2 Massoud, Ahmed
Shaban, Khaled
author2_role author
author
author_facet Aya, Amer
Massoud, Ahmed
Shaban, Khaled
author_role author
dc.creator.none.fl_str_mv Aya, Amer
Massoud, Ahmed
Shaban, Khaled
dc.date.none.fl_str_mv 2024-10-17T06:20:37Z
2024-03-30
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://dx.doi.org/10.1016/j.heliyon.2024.e27021
Amer, A., Massoud, A., & Shaban, K. (2024). Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions. Heliyon, 10(6).‏
24058440
https://www.sciencedirect.com/science/article/pii/S2405844024030524
http://hdl.handle.net/10576/60184
6
10
dc.language.none.fl_str_mv en
dc.publisher.none.fl_str_mv Elsevier Ltd
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
info:eu-repo/semantics/openAccess
dc.subject.none.fl_str_mv Energy management system (EMS)
Power stations
Diesel generator
Degradation cost
Renewable energy
dc.title.none.fl_str_mv Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions
dc.type.none.fl_str_mv Article
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Renewable energy sources have immense potential for enhancing environmental sustainability; however, addressing their intermittency and irregularity is vital for optimizing economic benefits within microgrids. Integrating renewable energy systems with energy storage presents a promising solution. This study introduces an innovative energy management system designed for hybrid renewable power stations, incorporating battery energy storage systems and diesel generators. By accounting for battery degradation costs associated with charge depth and lifespan, the study transforms long-term battery expenses into real-time operational costs. The optimization problem is formulated as a mixed integer linear programming framework with the objectives of minimizing operating costs, battery degradation costs, and pollutant gas emissions. Through diverse case studies reflecting various market profiles. The proposed approach demonstrates reductions in overall system costs.
eu_rights_str_mv openAccess
format article
id qu_4e3925fff80532bb250920a1222b237f
identifier_str_mv Amer, A., Massoud, A., & Shaban, K. (2024). Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions. Heliyon, 10(6).‏
24058440
6
10
language_invalid_str_mv en
network_acronym_str qu
network_name_str Qatar University repository
oai_identifier_str oai:qspace.qu.edu.qa:10576/60184
publishDate 2024
publisher.none.fl_str_mv Elsevier Ltd
repository.mail.fl_str_mv
repository.name.fl_str_mv
repository_id_str
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc/4.0/
spelling Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissionsAya, AmerMassoud, AhmedShaban, KhaledEnergy management system (EMS)Power stationsDiesel generatorDegradation costRenewable energyRenewable energy sources have immense potential for enhancing environmental sustainability; however, addressing their intermittency and irregularity is vital for optimizing economic benefits within microgrids. Integrating renewable energy systems with energy storage presents a promising solution. This study introduces an innovative energy management system designed for hybrid renewable power stations, incorporating battery energy storage systems and diesel generators. By accounting for battery degradation costs associated with charge depth and lifespan, the study transforms long-term battery expenses into real-time operational costs. The optimization problem is formulated as a mixed integer linear programming framework with the objectives of minimizing operating costs, battery degradation costs, and pollutant gas emissions. Through diverse case studies reflecting various market profiles. The proposed approach demonstrates reductions in overall system costs.Elsevier Ltd2024-10-17T06:20:37Z2024-03-30Articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://dx.doi.org/10.1016/j.heliyon.2024.e27021Amer, A., Massoud, A., & Shaban, K. (2024). Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions. Heliyon, 10(6).‏24058440https://www.sciencedirect.com/science/article/pii/S2405844024030524http://hdl.handle.net/10576/60184610enhttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessoai:qspace.qu.edu.qa:10576/601842024-10-17T19:04:53Z
spellingShingle Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions
Aya, Amer
Energy management system (EMS)
Power stations
Diesel generator
Degradation cost
Renewable energy
status_str publishedVersion
title Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions
title_full Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions
title_fullStr Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions
title_full_unstemmed Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions
title_short Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions
title_sort Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions
topic Energy management system (EMS)
Power stations
Diesel generator
Degradation cost
Renewable energy
url http://dx.doi.org/10.1016/j.heliyon.2024.e27021
https://www.sciencedirect.com/science/article/pii/S2405844024030524
http://hdl.handle.net/10576/60184