Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions
Renewable energy sources have immense potential for enhancing environmental sustainability; however, addressing their intermittency and irregularity is vital for optimizing economic benefits within microgrids. Integrating renewable energy systems with energy storage presents a promising solution. Th...
Saved in:
| Main Author: | |
|---|---|
| Other Authors: | , |
| Format: | article |
| Published: |
2024
|
| Subjects: | |
| Online Access: | http://dx.doi.org/10.1016/j.heliyon.2024.e27021 https://www.sciencedirect.com/science/article/pii/S2405844024030524 http://hdl.handle.net/10576/60184 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1857415084449464320 |
|---|---|
| author | Aya, Amer |
| author2 | Massoud, Ahmed Shaban, Khaled |
| author2_role | author author |
| author_facet | Aya, Amer Massoud, Ahmed Shaban, Khaled |
| author_role | author |
| dc.creator.none.fl_str_mv | Aya, Amer Massoud, Ahmed Shaban, Khaled |
| dc.date.none.fl_str_mv | 2024-10-17T06:20:37Z 2024-03-30 |
| dc.format.none.fl_str_mv | application/pdf |
| dc.identifier.none.fl_str_mv | http://dx.doi.org/10.1016/j.heliyon.2024.e27021 Amer, A., Massoud, A., & Shaban, K. (2024). Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions. Heliyon, 10(6). 24058440 https://www.sciencedirect.com/science/article/pii/S2405844024030524 http://hdl.handle.net/10576/60184 6 10 |
| dc.language.none.fl_str_mv | en |
| dc.publisher.none.fl_str_mv | Elsevier Ltd |
| dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc/4.0/ info:eu-repo/semantics/openAccess |
| dc.subject.none.fl_str_mv | Energy management system (EMS) Power stations Diesel generator Degradation cost Renewable energy |
| dc.title.none.fl_str_mv | Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions |
| dc.type.none.fl_str_mv | Article info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/article |
| description | Renewable energy sources have immense potential for enhancing environmental sustainability; however, addressing their intermittency and irregularity is vital for optimizing economic benefits within microgrids. Integrating renewable energy systems with energy storage presents a promising solution. This study introduces an innovative energy management system designed for hybrid renewable power stations, incorporating battery energy storage systems and diesel generators. By accounting for battery degradation costs associated with charge depth and lifespan, the study transforms long-term battery expenses into real-time operational costs. The optimization problem is formulated as a mixed integer linear programming framework with the objectives of minimizing operating costs, battery degradation costs, and pollutant gas emissions. Through diverse case studies reflecting various market profiles. The proposed approach demonstrates reductions in overall system costs. |
| eu_rights_str_mv | openAccess |
| format | article |
| id | qu_4e3925fff80532bb250920a1222b237f |
| identifier_str_mv | Amer, A., Massoud, A., & Shaban, K. (2024). Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions. Heliyon, 10(6). 24058440 6 10 |
| language_invalid_str_mv | en |
| network_acronym_str | qu |
| network_name_str | Qatar University repository |
| oai_identifier_str | oai:qspace.qu.edu.qa:10576/60184 |
| publishDate | 2024 |
| publisher.none.fl_str_mv | Elsevier Ltd |
| repository.mail.fl_str_mv | |
| repository.name.fl_str_mv | |
| repository_id_str | |
| rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc/4.0/ |
| spelling | Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissionsAya, AmerMassoud, AhmedShaban, KhaledEnergy management system (EMS)Power stationsDiesel generatorDegradation costRenewable energyRenewable energy sources have immense potential for enhancing environmental sustainability; however, addressing their intermittency and irregularity is vital for optimizing economic benefits within microgrids. Integrating renewable energy systems with energy storage presents a promising solution. This study introduces an innovative energy management system designed for hybrid renewable power stations, incorporating battery energy storage systems and diesel generators. By accounting for battery degradation costs associated with charge depth and lifespan, the study transforms long-term battery expenses into real-time operational costs. The optimization problem is formulated as a mixed integer linear programming framework with the objectives of minimizing operating costs, battery degradation costs, and pollutant gas emissions. Through diverse case studies reflecting various market profiles. The proposed approach demonstrates reductions in overall system costs.Elsevier Ltd2024-10-17T06:20:37Z2024-03-30Articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://dx.doi.org/10.1016/j.heliyon.2024.e27021Amer, A., Massoud, A., & Shaban, K. (2024). Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions. Heliyon, 10(6).24058440https://www.sciencedirect.com/science/article/pii/S2405844024030524http://hdl.handle.net/10576/60184610enhttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessoai:qspace.qu.edu.qa:10576/601842024-10-17T19:04:53Z |
| spellingShingle | Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions Aya, Amer Energy management system (EMS) Power stations Diesel generator Degradation cost Renewable energy |
| status_str | publishedVersion |
| title | Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions |
| title_full | Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions |
| title_fullStr | Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions |
| title_full_unstemmed | Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions |
| title_short | Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions |
| title_sort | Optimization of hybrid renewable-diesel power plants considering operational cost, battery degradation, and emissions |
| topic | Energy management system (EMS) Power stations Diesel generator Degradation cost Renewable energy |
| url | http://dx.doi.org/10.1016/j.heliyon.2024.e27021 https://www.sciencedirect.com/science/article/pii/S2405844024030524 http://hdl.handle.net/10576/60184 |