-
1
-
2
Ferroelectric Properties and Electrocaloric Effect in Dy2O3 Substitution on Lead-Free (Na0.5 Bi0.5)0.94 Ba0.06TiO3 Ceramic
منشور في 2023"…Using the direct EC measurement, the ceramic corresponding to y = 0.02 exhibited a significant EC response, where ΔT = 1.2 K under 5 kV/mm. …"
احصل على النص الكامل
-
3
Host Genetic Variants Potentially Associated With SARS-CoV-2: A Multi-Population Analysis
منشور في 2020"…We also collected the expression data of these SNPs from the expression quantitative trait loci (eQTLs) databases. Sequences from Qatar Genome Programme (QGP, n = 6,054) and 1000Genome project were used to calculate and compare allelic frequencies (AF).…"
-
4
-
5
Genome-Wide Association Study of Vitamin D Deficiency in the Middle East With a Relevant Characterization of the Novel <i>SDR42E1 </i>Gene
منشور في 2023"…Significant gene associations between the SDR42E1 and genes involved in Vitamin D pathways were identified, including alkaline phosphatase, placental type (ALPP), ATP-binding cassette C1 (ABCC1), solute carrier 7A5 (SLC7A5). …"
-
6
Crystallization properties of arsenic doped GST alloys
منشور في 2019"…The crystallization temperature (T<sub>c</sub>) of (GST)<sub>0.85</sub>As<sub>0.15</sub> is higher than the T<sub>c</sub> observed in GST. Optical band gap (E<sub>opt</sub>) values of the as-deposited films show a clear increasing trend; 0.6 eV for GST to 0.76 eV for (GST)<sub>0.85</sub>As<sub>0.15</sub>. …"
-
7
Effect of sintering temperature of NBT–6BT lead-free ceramics on the structural, ferroelectric and piezoelectric properties
منشور في 2022"…The lead-free Na 0.5 Bi 0.5 0.94 Ba 0.06 TiO 3 (NBT-6BT) ceramics was fabricated at various sintering temperatures using a conventional solid-state reaction method. …"
احصل على النص الكامل
-
8
-
9
-
10
-
11
-
12
-
13
A robust experimental-based artificial neural network approach for photovoltaic maximum power point identification considering electrical, thermal and meteorological impact
منشور في 2020"…Nonetheless, the consideration of irradiance, electrical, thermal, and weather parameters (scenario IV) yielded higher identification accuracy. The results showed a decrease in the MSE of V<sub>mp</sub> by 74.3% (from 1.6 V to 0.411 V), and in the MSE of I<sub>mp</sub> by 95% (from 4.4e−6 A to 2.16e−7 A), respectively. …"
-
14
-
15
-
16
-
17
High-sensitive detection and quantitation of thyroid-stimulating hormone (TSH) from capillary/fingerstick and venepuncture whole-blood using fluorescence-based rapid lateral flow i...
منشور في 2023"…Methods102 fingerstick, venepuncture whole-blood, and serum samples (with normal and abnormal TSH values) were analyzed by Finecare™ Rapid Quantitative LFIA test and Roche cobas® e 601 as a reference test. ResultsUsing serum, when compared to cobas® e 601 reference method, Finecare™ showed high sensitivity [90.5 % (69.6–98.8)] and specificity [96.3 % (89.6–99.2)] for diagnosis of thyroid abnormalities (<0.35 or >4.5 mIU/L). …"
احصل على النص الكامل
احصل على النص الكامل
احصل على النص الكامل
article -
18
High-sensitive detection and quantitation of thyroid-stimulating hormone (TSH) from capillary/fingerstick and venepuncture whole-blood using fluorescence-based rapid lateral flow i...
منشور في 2023"…</p><h3>Methods </h3><p dir="ltr">102 fingerstick, venepuncture whole-blood, and serum samples (with normal and abnormal TSH values) were analyzed by Finecare™ Rapid Quantitative LFIA test and Roche cobas® e 601 as a reference test. </p><h3>Results </h3><p dir="ltr">Using serum, when compared to cobas® e 601 reference method, Finecare™ showed high sensitivity [90.5 % (69.6–98.8)] and specificity [96.3 % (89.6–99.2)] for diagnosis of thyroid abnormalities (<0.35 or >4.5 mIU/L). …"
-
19
-
20