يعرض 1 - 20 نتائج من 61 نتيجة بحث عن '(( chd levels increased ) OR ((( c large decrease ) OR ( c marked decrease ))))', وقت الاستعلام: 0.12s تنقيح النتائج
  1. 1
  2. 2
  3. 3

    Operation optimization of propane pre-cooled mixed refrigerant LNG Process: A novel integration of knowledge-based and constrained Bayesian optimization approaches حسب Roba Shady (22048043)

    منشور في 2024
    "…In addition, the optimized SEC in this study is 14.5 % to 38.6 % lower than those reported in the literature. At large-scale LNG production (10,000 tons per day), the reduction in the SEC is translated into an 18 MW decrease in compression power, saving approximately 4.7 million $ per year for each C3MR train. …"
  4. 4
  5. 5
  6. 6
  7. 7

    Isolation and study of Lipase activity of an olive oil degrading Thermoactionomyces SP. (c2002) حسب Al Khudary, Rami

    منشور في 2002
    "…A ftlamentous, Gram-Positive, spore forming filamentous bacterium was isolated from soil (AI Koura - Lebanon) on rhodamine agar plates at 60°C. The isolate, HRK-l produced large quantities of an extra cellular thermostable lipase that degrades olive oil. …"
    احصل على النص الكامل
    احصل على النص الكامل
    masterThesis
  8. 8
  9. 9
  10. 10
  11. 11
  12. 12
  13. 13
  14. 14

    DNAJB3 attenuates metabolic stress and promotes glucose uptake by eliciting Glut4 translocation حسب Abdelilah Arredouani (10914455)

    منشور في 2019
    "…Using JNK1- and IKKβ-dependent luciferase reporters, we show a marked decrease in luciferase activity by DNAJB3 in response to PMA and TNF-α that was consistent with a decrease in the translocation of p65/NF-κB to the nucleus in response to LPS. …"
  15. 15
  16. 16

    Hypoxic Stress Induces Complement-Mediated Lysis of Mesenchymal Stem Cells by Downregulating Factor H and CD59 حسب Ramada R. Khaswaneh (22224544)

    منشور في 2024
    "…The level of complement system related factors; Factor H, CD59, C3b, iC3b, C5b, C9, and the complement membrane attack complex (MAC) were analyzed using Elisa assays, western blotting, and immunocytochemistry.…"
  17. 17
  18. 18

    A Numerical Study of Heat Transfer and Fluid Flow in a Channel with an Array of Pin Fins in Aligned and Staggered Configurations حسب Issa, Johnny

    منشور في 2018
    "…For fin arrays with a large row number in the streamwise direction, the best performance was obtained in the case corresponding to the aligned configuration with the large spacing ratio, S* = 1.…"
    احصل على النص الكامل
    احصل على النص الكامل
    احصل على النص الكامل
    احصل على النص الكامل
    conferenceObject
  19. 19

    Behavior of axially loaded drilled shaft foundations with symmetric voids outside and inside the caging حسب Abishdid, Caesar

    منشور في 2014
    "…The findings indicate that the voids Type B decrease the capacity and stiffness of drilled shafts more than other types due to the resulting inadequate confinement of the concrete and reinforcement.…"
    احصل على النص الكامل
    احصل على النص الكامل
    احصل على النص الكامل
    احصل على النص الكامل
    article
  20. 20