Search alternatives:
nm decrease » _ decrease (Expand Search)
fe decrease » _ decrease (Expand Search)
a decrease » _ decrease (Expand Search), _ decreased (Expand Search), _ decreases (Expand Search)
5 nm » 6 nm (Expand Search)
_ fe » _ e (Expand Search)
nm decrease » _ decrease (Expand Search)
fe decrease » _ decrease (Expand Search)
a decrease » _ decrease (Expand Search), _ decreased (Expand Search), _ decreases (Expand Search)
5 nm » 6 nm (Expand Search)
_ fe » _ e (Expand Search)
-
1
Structural and magnetic properties of Ni1-xZnxFe 2O4 (x=0, 0.5 and 1) nanopowders prepared by sol-gel method
Published 2013“…A series of nanostructured Ni-Zn ferrites Ni1-xZn xFe2O4 (x=0, 0.5 and 1) with a grain size from 24 to 65 nm have been prepared with a sol-gel method. …”
Get full text
Get full text
-
2
-
3
Functionalization of silica-coated magnetic nanoparticles as powerful demulsifier to recover oil from oil-in-water emulsion
Published 2021“…The Fe–Si-MNP exhibited excellent %Soil, reliable stability, and high magnetization values ranging between 46.1 and 80.2 emu/g. adding a 5 nm silica layer on the surface of the Fe–Si-MNP (i.e., Fe–Si-1) protected them from oxidation conditions, extended their service life, and achieved a %Soil of ∼96.3%. …”
Get full text
Get full text
-
4
Application of natural compounds–based gold nanoparticles for the treatment of hemolytic anemia in an anemic mouse model: Formulation of a novel drug from relationship between the...
Published 2020“…TEM and FE-SEM images showed the biosynthesized nanoparticles as having a uniform spherical morphology and diameters in the range of 5–30 nm. …”
Get full text
Get full text
Get full text
-
5
Fabrication of Selective Sensors for Hg2+ Traces in Water Using Graphene Decorated with Metal Nanoclusters
Published 2016“…Two batches of sensors were tested in this work: i) sensors based on graphene only, and ii) sensors based on graphene and percolating films of Au nanoclusters, each has a thickness of 5 nm. For nanocluster deposition, each graphene sample was fixed on a cryostat finger. …”
Get full text
Get full text
-
6
Structural influence of chromium substituted magnetite ferrofluids on the optical and antibacterial characteristics
Published 2023“…As the composition of Cr increases from x = 0.2 to x = 0.8, the crystalline size decreases reaching a minimum value of 9 nm. At the same time, the magnetic moment also becomes 1.3 +- 0.08 at a saturation point of 33 +- 0.13 emu/g at the highest Cr composition. …”
Get full text
Get full text