Showing 1 - 20 results of 186 for search '(((( 50 ((nn decrease) OR (mean decrease)) ) OR ( 50 ngsn decrease ))) OR ( 10 mg decrease ))', query time: 0.16s Refine Results
  1. 1
  2. 2
  3. 3
  4. 4

    Biocorrosion behavior of biodegradable nanocomposite fibers coated layer-by-layer on AM50 magnesium implant by Abdal-hay, Abdalla

    Published 2016
    “…The corrosion performance of coated and uncoated coupon samples was investigated by means of electrochemical measurements. The results showed that the AJS 3D membrane fiber layers, particularly the hybrid membrane layers containing a small amount of nHA (3wt.%), induce a higher biocorrosion resistance and effectively decrease the initial degradation rate compared with the neat AM50 coupon samples. …”
    Get full text
    Get full text
  5. 5

    Effect of copper-nickel interlayer thickness on laser welding-brazing of Mg/Ti alloy by Auwal, S.T.

    Published 2019
    “…Dissimilar lap joining of AZ31B Mg alloy to Cu-Ni coated Ti-6Al-4V was carried out by laser welding-brazing method. …”
    Get full text
    Get full text
  6. 6
  7. 7
  8. 8
  9. 9
  10. 10
  11. 11
  12. 12
  13. 13
  14. 14
  15. 15
  16. 16

    Effects of Combined Calcium Hypochlorite and Chlorine Dioxide on Drinking Water Quality in Qatar and Disinfection by Products Formation by Mohamed, Elsamoul H.

    Published 2016
    “…Seven water samples were collected from the Ras Laffan-Q Power desalination plant outlet in amber bottles having a chlorine dioxide concentration of 0.3 mg/l in 1 liter. The bottles were spiked with Ca(ClO)2 in sequence to give concentration of 0.2, 0.4, 0.6, 0.8, 1.0, and 1.2 mg/l as free chlorine. …”
    Get full text
    Get full text
  17. 17

    Does the Mediterranean Diet Have Any Effect on Lipid Profile, Central Obesity and Liver Enzymes in Non-Alcoholic Fatty Liver Disease (NAFLD) Subjects? A Systematic Review and Meta-... by Del Bo', Cristian

    Published 2023
    “…According to the results, the MD seems to decrease the liver stiffness (kPa) by –0.42 (CI95% –0.92, 0.09) (p = 0.10) and significantly reduce the TC by –0.46 mg/dl (CI95% –0.55, −0.38) (p = 0.001), while no significant findings were documented for liver enzymes and WC among patients with NAFLD. …”
    Get full text
    Get full text
  18. 18
  19. 19
  20. 20

    The Structure of the Free Volume in Poly(styrene-co-acrylonitrile) from Positron Lifetime and Pressure Volume Temperature (PVT) Experiments by Dlubek, Gunter

    Published 2004
    “…The mean hole volume, vh, varies in PS between 105 Å3 (27 °C) and 220 Å3 (190 °C), and shows a systematic decrease with increasing AN content, at Tg from 121 Å3 for PS to 102 (±2) Å3 for SAN50. …”
    Get full text
    Get full text