    Corrosion behavior of API X100 steel material in a hydrogen sulfide environment by Okonkwo, Paul C.

    Published 2017
    “…The results indicate that the corrosion rate of API X100 steel decreases with increasing H2S bubbling time due to the increase in H2S concentration in 3.5% NaCl solutions. …”
    Get full text
    Get full text
  3. 3

    Corrosion inhibition of API X120 steel in a highly aggressive medium using stearamidopropyl dimethylamine by Radwan, A.Bahgat

    Published 2017
    “…The overall results showed that SAPDA significantly decreased the corrosion rate of API X120 steel with an inhibition efficiency of approximately 99% at an inhibitor concentration of 136 μmol L− 1. …”
    Get full text
    Get full text
  4. 4
  5. 5

    Electrochemical and thermodynamic study on the corrosion performance of API X120 steel in 3.5% NaCl solution by Shahzad, Khuram

    Published 2020
    “…The overall results revealed that PEI significantly decreases the corrosion rate of API X120 steel with inhibition efficiency of 94% at a concentration of 100 μmol L−1. …”
    Get full text
    Get full text
    Get full text
  6. 6
  7. 7
  8. 8

    Caprylamidopropyl Betaine as a Highly Efficient eco-friendly Corrosion Inhibitor for API X120 Steel in 1 M H2SO4 by Foudaa, Abd El Aziz S.

    Published 2020
    “…The overall results displayed that the corrosion rate of API X120 steel was significantly lowered with improving the temperature. …”
    Get full text
    Get full text
    Get full text
  9. 9
  10. 10
  11. 11
  12. 12
  13. 13

    Corrosion behavior of API-X120 carbon steel alloy in a GTL F-T process water environment at low COD concentration by Ewis, Dina

    Published 2020
    “…The effect of temperature, time and rotation speed of FT-GTL process water on the corrosion rate of API X-120 carbon steel was investigated. Electrochemical impedance spectroscopy and potentiodynamic polarization techniques were used to determine the carbon steel corrosion rate under temperatures ranging from 293 to 323 K and rotation speed of 0, 500, 1000, 2000 rpm when the immersion time was 0.5, 1, and 2 h. …”
    Get full text
    Get full text
  14. 14
  15. 15
  16. 16
  17. 17
  18. 18
  19. 19

    Evidence of two mechanisms involved in Bacillus thuringiensis israelensis decreased toxicity against mosquito larvae: Genome dynamic and toxins stability by Elleuch, Jihen

    Published 2015
    “…The obtained results describe two main reasons of the decrease of B. thuringiensis israelensis insecticidal activity. …”
    Get full text
    Get full text
  20. 20

    Quality improvement can decrease blood delivery turnaround time: Evidence from a single tertiary-care academic medical center by Hammad Y.A.

    Published 2018
    “…The transport time significantly decreased from an initial majority of > 15 mins duration, to a majority of < 15 mins transport time after the second audit; there was a 50% improvement in 30 mins response time; and the percentage of requests processed in < 10 mins were significantly higher after the second audit. …”
    Get full text