    Recycled Polypropylene Fibres for Reinforcing Cement Mortar under Arid Conditions by Bendjillali, Khadra

    Published 2023
    “…It is also shown that under arid conditions, the presence of 1% of recycled polypropylene fibres in cement mortar leads to a considerable decrease in total shrinkage of about 46% and an increase in the flexural and compressive strength of about 24% and 26%, respectively, compared to control mortar (CM) at the age of 194 days. …”
    Get full text
    Get full text
  2. 622

    Study of performance, combustion, and emissions parameters of DI-diesel engine fueled with algae biodiesel/diesel/n-pentane blends by Elkelawy, Medhat

    Published 2021
    “…Due to the disadvantages of using pure biodiesel in engines, it was used as B50 (a blend of 50% diesel and 50% biodiesel). To enhance engine performance, n-pentane was used in different extents of 5, 10, and 15 ml per liter as an enhancer additive. …”
    Get full text
    Get full text
  3. 623

    High-Rate Anaerobic Digestion of Waste Activated Sludge by Integration of Electro-Fenton Process by Feki, Emna

    Published 2020
    “…Following EF pretreatment, the pH, conductivity, soluble chemical oxygen demand (SCOD), and volatile fatty acids (VFA) increased to 7.5, 13.72 mS/cm, 4.1 g/L, and 925 mg/L, respectively. Capillary suction time (CST) analysis highlighted the dewaterability effect of EF on WAS, as demonstrated by the decrease in CST from 429 to 180 s following 30 min of pretreatment. …”
    Get full text
    Get full text
  4. 624
  5. 625
  6. 626

    Understanding the mechanisms mediating cardio-renal benefit of empagliflozin in type 2 diabetes mellitus by Dimitrios, Patoulias

    Published 2023
    “…They have demonstrated1 that empagliflozin treatment resulted in a significant decrease in pulse pressure (PP), mean arterial pressure (MAP) and cardiac workload, compared with placebo; at week 12, placebo-adjusted mean changes from baseline were − 2.5 mmHg for PP, − 2.2 mmHg for MAP and − 315 mmHg x beats per minute (bpm) for cardiac workload (p < 0.0001 for all). …”
    Get full text
    Get full text
    Get full text
  7. 627
  8. 628

    Novel fluorinated surfactants for enhanced oil recovery in carbonate reservoirs by Al-Amodi, Adel O.

    Published 2016
    “…However, betaine‐based co‐surfactant reduced the IFT to 10−3 mN/m. An adsorption isotherm showed that the maximum adsorption of surfactant‐A was 1 mg per g of rock. …”
    Get full text
    Get full text
  9. 629

    Absorption of CO2 in aqueous blend of methyldiethanolamine and arginine by Talkhan, Ahmed Gomaa

    Published 2020
    “…The study was carried out at different mixing ratios of MDEA and Arg at a total concentration of 2 moles per litre. The CO2 partial pressure varied from about 10 to 100 kPa, and the temperature varied from 293 K to 323 K. …”
    Get full text
    Get full text
  10. 630
  11. 631
  12. 632
  13. 633

    Climatology and variability of wind speeds along the southwest coast of India derived from Climate Forecast System Reanalysis winds by Abdulla, Cheriyeri Poyil

    Published 2022
    “…Southwest monsoon has contributed the highest weakening trends (−3.0 to −4.0 cm·s−1·year−1) due to significant decrease in the southwesterly/westerly wind speeds. …”
    Get full text
    Get full text
    Get full text
  14. 634

    Synthesizing New Anodes From Qatalum's 1st Cut Spl by Hani Holozadah, Abdullah

    Published 2014
    “…This might result in extending the life time of the carbon anodes and decrease the number of carbon dioxide kilograms that are released per a ton of produced Al metal. …”
    Get full text
    Get full text
  15. 635
  16. 636
  17. 637
  18. 638
  19. 639

    Concrete Pavement Truck Equivalence Factors For Upgrades by Razouki, Sabah Said

    Published 1999
    “…The upgrade truck equivalence factors were developed taking into consideration the following three values for upgrade namely; 0%, 8% and 12%, four values of slab thickness namely; 6, 8, 10 and 12 inches (15.24, 20.32, 25.40 and 30.48cm) and two extreme ratios of H / B of 0.2 and 1.0. …”