Showing 16,381 - 16,400 results of 42,915 for search '(( 5 ((mean decrease) OR (point decrease)) ) OR ( 100 ((nn decrease) OR (a decrease)) ))', query time: 1.30s Refine Results
  1. 16381
  2. 16382
  3. 16383
  4. 16384

    Structure diagram of mobile and hitching base. by Liang Ge (541067)

    Published 2024
    “…The experimental results show that: (1) The liquid volume in a tank of vacuum degree within 2.0 Pa and 200 mm interlayer reduced no more than 15.5% after 48 days; (2) Taking the pressure in the tank as the power source, because of environmental differences inside and outside the pipe after 100 m pressure holding delivery, the physical form of liquid and gas could be converted instantly; (3) The continuous discharge time without ice blocking for a tank full of 2 m<sup>3</sup> liquid was about 10.5 min under 25 L dual mode nitrogen pressurization, which is 1/12 of injection time after ground gasification; (4) Based on the temperature decrease trend measured at different positions, the cooling characteristics on liquid gasification jet path are quantified, and the calculation formula of temperature changing with time on the center line of liquid gasification jet is obtained. …”
  5. 16385

    Structure diagram of insulation storage tank. by Liang Ge (541067)

    Published 2024
    “…The experimental results show that: (1) The liquid volume in a tank of vacuum degree within 2.0 Pa and 200 mm interlayer reduced no more than 15.5% after 48 days; (2) Taking the pressure in the tank as the power source, because of environmental differences inside and outside the pipe after 100 m pressure holding delivery, the physical form of liquid and gas could be converted instantly; (3) The continuous discharge time without ice blocking for a tank full of 2 m<sup>3</sup> liquid was about 10.5 min under 25 L dual mode nitrogen pressurization, which is 1/12 of injection time after ground gasification; (4) Based on the temperature decrease trend measured at different positions, the cooling characteristics on liquid gasification jet path are quantified, and the calculation formula of temperature changing with time on the center line of liquid gasification jet is obtained. …”
  6. 16386

    Change of liquid volume and pressure in the tank. by Liang Ge (541067)

    Published 2024
    “…The experimental results show that: (1) The liquid volume in a tank of vacuum degree within 2.0 Pa and 200 mm interlayer reduced no more than 15.5% after 48 days; (2) Taking the pressure in the tank as the power source, because of environmental differences inside and outside the pipe after 100 m pressure holding delivery, the physical form of liquid and gas could be converted instantly; (3) The continuous discharge time without ice blocking for a tank full of 2 m<sup>3</sup> liquid was about 10.5 min under 25 L dual mode nitrogen pressurization, which is 1/12 of injection time after ground gasification; (4) Based on the temperature decrease trend measured at different positions, the cooling characteristics on liquid gasification jet path are quantified, and the calculation formula of temperature changing with time on the center line of liquid gasification jet is obtained. …”
  7. 16387
  8. 16388

    Association and dissociation of BODIPY FL GTPγS with PfG from <i>Plasmodium</i>. by Annette Kaiser (386455)

    Published 2015
    “…The increase in fluorescence was monitored until saturation over a time interval of 600 s. Part B At the arrow at t = 200 s, 20 μM unlabeled GTPγS was added and the decrease in fluorescence was monitored. …”
  9. 16389

    Range of motion. by Seung Joon Rhee (19507154)

    Published 2024
    “…<div><p>This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. …”
  10. 16390

    Patient demographics. by Seung Joon Rhee (19507154)

    Published 2024
    “…<div><p>This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. …”
  11. 16391

    Radiological outcomes. by Seung Joon Rhee (19507154)

    Published 2024
    “…<div><p>This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. …”
  12. 16392

    Clinical outcomes. by Seung Joon Rhee (19507154)

    Published 2024
    “…<div><p>This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. …”
  13. 16393

    S1 Data - by Seung Joon Rhee (19507154)

    Published 2024
    “…<div><p>This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. …”
  14. 16394

    Muscle activities during walking and running at energetically optimal transition speed under normobaric hypoxia on gradient slopes by Daijiro Abe (797293)

    Published 2017
    “…<div><p>Energy cost of transport per unit distance (CoT; J·kg<sup>-1</sup>·km<sup>-1</sup>) displays a U-shaped fashion in walking and a linear fashion in running as a function of gait speed (<i>v</i>; km·h<sup>-1</sup>). There exists an intersection between U-shaped and linear CoT-<i>v</i> relationships, being termed energetically optimal transition speed (EOTS; km·h<sup>-1</sup>). …”
  15. 16395
  16. 16396

    Deviation from standard dose-response curve by bnMAbs in a U87 target cell assay. by Laura E. McCoy (386535)

    Published 2015
    “…The data points are colored according to which site the bnMAb targets: high-mannose patch (magenta), CD4bs (red), V2 apex (blue), and MPER (green). …”
  17. 16397

    OPJ: Origin data for Fig 9a. by Nacer Badi (14046883)

    Published 2024
    “…According to the computational results, the tilt angle and modified Rayleigh number increase the mass flow rate and mean Nusselt number. The overheating zone with maximum temperatures is located in the upper part of the photovoltaic panel. …”
  18. 16398

    OPJ: Origin data for Fig 7a. by Nacer Badi (14046883)

    Published 2024
    “…According to the computational results, the tilt angle and modified Rayleigh number increase the mass flow rate and mean Nusselt number. The overheating zone with maximum temperatures is located in the upper part of the photovoltaic panel. …”
  19. 16399

    OPJ: Origin data for Fig 3a. by Nacer Badi (14046883)

    Published 2024
    “…According to the computational results, the tilt angle and modified Rayleigh number increase the mass flow rate and mean Nusselt number. The overheating zone with maximum temperatures is located in the upper part of the photovoltaic panel. …”
  20. 16400

    OPJ: Origin data for Fig 4b. by Nacer Badi (14046883)

    Published 2024
    “…According to the computational results, the tilt angle and modified Rayleigh number increase the mass flow rate and mean Nusselt number. The overheating zone with maximum temperatures is located in the upper part of the photovoltaic panel. …”