Showing 1 - 8 results of 8 for search '(( 5 ((ppm decrease) OR (_ decrease)) ) OR ((( 50 c decrease ) OR ( 10 mm decrease ))))~', query time: 0.62s Refine Results
  1. 1

    A 60-year-old male with a hyperacute cardioembolic infarction fifteen hours after the onset. by Daichi Momosaka (6160418)

    Published 2020
    “…<b>G:</b> MTR<sub>asym</sub> spectra show decreased MTR<sub>asym</sub> (3.5ppm) or APTW signal (%) in the infarct area compared to the CNAWM. mRS, modified Rankin Scale; NIHSS, National Institutes of Health Stroke Scale; FLAIR, fluid attenuated inversion recovery; DWI, diffusion-weighted imaging; ROI, region-of-interest; ADC, apparent diffusion coefficient; APTW, amide proton transfer-weighted; CEST, chemical exchange saturation transfer; CNAWM, contralateral normal-appearing white matter; S<sub>sat</sub>(ppm) and S0, the signal intensities obtained with and without selective radiofrequency saturation pulse irradiation, respectively; APT<sub>10</sub>, APT<sub>25</sub>, APT<sub>50</sub>, APT<sub>75</sub>, and APT<sub>90</sub> correspond to the 10th, 25th, 50th, 75th, and 90th percentiles of the APTW signal value within the ROI, respectively.…”
  2. 2

    A 27-year-old female with an acute cardioembolic infarction fifteen hours after the onset. by Daichi Momosaka (6160418)

    Published 2020
    “…<b>G:</b> MTR<sub>asym</sub> spectra show decreased MTR<sub>asym</sub>(3.5ppm) or APTW signal (%) in the infarct area compared to the CNAWM. mRS, modified Rankin Scale; NIHSS, National Institutes of Health Stroke Scale; FLAIR, fluid attenuated inversion recovery; DWI, diffusion-weighted imaging; ROI, region-of-interest; ADC, apparent diffusion coefficient; APTW, amide proton transfer-weighted; CEST, chemical exchange saturation transfer; CNAWM, contralateral normal-appearing white matter; S<sub>sat</sub>(ppm) and S<sub>0</sub>, the signal intensities obtained with and without selective radiofrequency saturation pulse irradiation, respectively; APT<sub>10</sub>, APT<sub>25</sub>, APT<sub>50</sub>, APT<sub>75</sub>, and APT<sub>90</sub>, correspond to the 10th, 25th, 50th, 75th, and 90th percentiles of APTW signal value, respectively.…”
  3. 3

    A 59-year-old male with a subacute atherosclerotic infarction nine days after the onset. by Daichi Momosaka (6160418)

    Published 2020
    “…<b>G:</b> MTR<sub>asym</sub> spectra show decreased MTR<sub>asym</sub>(3.5ppm) or APTW signal (%) in the infarct area compared to the CNAWM. mRS, modified Rankin Scale; NIHSS, National Institutes of Health Stroke Scale; FLAIR, fluid attenuated inversion recovery; DWI, diffusion-weighted imaging; ROI, region-of-interest; ADC, apparent diffusion coefficient; APTW, amide proton transfer-weighted; CEST, chemical exchange saturation transfer; CNAWM, contralateral normal-appearing white matter; S<sub>sat</sub> (ppm) and S<sub>0</sub>, the signal intensities obtained with and without selective radiofrequency saturation pulse irradiation, respectively; APT<sub>10</sub>, APT<sub>25</sub>, APT<sub>50</sub>, APT<sub>75</sub>, and APT<sub>90</sub>, correspond to the 10th, 25th, 50th, 75th, and 90th percentiles of APTW signal value, respectively.…”
  4. 4

    <strong>Drought re-routes soil microbial carbon metabolism towards emission of volatile metabolites in an artificial tropical rainforest</strong> by Linnea Honeker (13113813)

    Published 2023
    “…For this study, the GC was equipped with a 30-m Rxi-624 column (Restek, 0.25 mm ID, 1.4 µm film thickness) which resolves non- to mid-polarity VOCs in the C5 - C12 volatility range prior to ionization in the PTR detector. …”
  5. 5

    Complementary interactions of cysteine and Fe(II) with 6PG. by Gabriel Piedrafita (155328)

    Published 2021
    “…<b>(B)</b> Representative <sup>1</sup>H-NMR spectra of 6PG alone, cysteine alone, or the combination of both (20 mM of each analyte) in 50 mM phosphate pH 5/D<sub>2</sub>O solutions, either in the absence or presence of 1 mM FeCl<sub>2</sub>. …”
  6. 6

    I-R-Polar-Negative-0902 by Sheng-Yuan Ho (16909464)

    Published 2023
    “…The mass spectrometer was configured as follows: negative ion mode, capillary voltage of 2 kV, source temperature of 120°C, desolvation gas N2 at 900 L/h at 550°C, cone gas N2 at 15 L/h, capillary voltage of 2.8 kV, cone voltage of 40 V, and time-of-flight mass spectrometry (TOF MS) scan range of 50 to 1000 m/z. …”
  7. 7

    Untargeted <i>In Vitro</i> Metabolomics data from <i>Burkholderia cenocepacia </i>J2315, H111 and <i>Staphylococcus aureus </i>NRS77 Biofilm Supernatant by Hayden Skaggs (20833868)

    Published 2025
    “…<br><br><b>METHODS</b></p><p dir="ltr"><br><b><u>Sample Collection</u></b><br>B. cenocepacia or Staphylococcus strains were inoculated into T LB Lennox + 1% glucose + 150 mM MOPS at 10^6 CFU/mL and incubated at 37 °C for 3 days in replicate wells of a 96-well PVC plate. …”
  8. 8

    Impacts of winter climate change on northern forest understory carbon dioxide exchange determined by reindeer grazing by Noora Kantola (14263490)

    Published 2025
    “…On the contrary, increased snow depth decreased C source strength inside the exclusion offsetting the difference between reindeer grazing treatments. …”