يعرض 1 - 6 نتائج من 6 نتيجة بحث عن '(( 5 ppm decrease ) OR ((((( _ zno decrease ) OR ( _ abt decrease ))) OR ( 3d point decrease ))))', وقت الاستعلام: 0.10s تنقيح النتائج
  1. 1

    Improved properties and salt rejection of polysulfone membrane by incorporation of hydrophilic cobalt-doped ZnO nanoparticles حسب Muneer M. Ba-Abbad (14151660)

    منشور في 2024
    "…The hydrophilicity of PSf membranes was improved by adding of ZnO and doped ZnO NPs which showed a decrease in contact angle values from 82° to 62° with an increased flux with water. …"
  2. 2

    Effect of surfactants on the convective heat transfer and pressure drop characteristics of ZnO/DIW nanofluids: An experimental study حسب Qamar, Adnan

    منشور في 2023
    "…Convective heat transfer (HTC) and flow characteristics (pressure drop (ΔP) and friction factor (f)) of aqueous ZnO NFs' within a circular mini tube (Di = 1.0 mm, L = 330 mm) were analyzed. …"
    احصل على النص الكامل
    احصل على النص الكامل
    احصل على النص الكامل
    article
  3. 3

    Effect of surfactants on the convective heat transfer and pressure drop characteristics of ZnO/DIW nanofluids: An experimental study حسب Adnan Qamar (14421759)

    منشور في 2023
    "…Convective heat transfer (HTC) and flow characteristics (pressure drop (ΔP) and friction factor (f)) of aqueous ZnO NFs' within a circular mini tube (D i = 1.0 mm, L = 330 mm) were analyzed. …"
  4. 4

    Stability enhancement of Al<sub>2</sub>O<sub>3</sub>, ZnO, and TiO<sub>2</sub> binary nanofluids for heat transfer applications حسب Ans Ahmed Memon (21633692)

    منشور في 2024
    "…It was concluded from the results that zeta potential increases in cases of (TiO<sub>2</sub> + ZnO) and (Al<sub>2</sub>O<sub>3</sub> + ZnO) from −44.2 to −47.8 mV and −42.4 to −44.1 mV with the addition of surfactant, respectively. …"
  5. 5

    Aortic valve function post-replacement of severe aortic stenosis by transcatheter procedure versus surgery: a systematic review and metanalysis حسب Charbel Abi Khalil (14150028)

    منشور في 2021
    "…TAVR was associated with 37% (95% CI [0.51–0.78) mean RR reduction of post-procedural PPM, a decrease that was not affected by the surgical risk at inclusion, neither by the transcatheter heart valve system. …"
  6. 6

    High-Performance Acetic Acid Sensing Using Cerium-MoS₂ Composite for Beverages and Food Processing Industry حسب E. Safamariyam (22330186)

    منشور في 2025
    "…Furthermore, the repeatability of the Ce<sub>0.6</sub> -MoS<sub>2</sub> sensor was assessed over 30 days, and a marginal decrease of 5% in response was observed from day 1 to day 30.…"