يعرض 1 - 20 نتائج من 487 نتيجة بحث عن '(( 50 ((a decrease) OR (_ decrease)) ) OR ((( 2 steel decrease ) OR ( _ 3d decrease ))))*', وقت الاستعلام: 0.23s تنقيح النتائج
  1. 1

    Quality improvement can decrease blood delivery turnaround time: Evidence from a single tertiary-care academic medical center حسب Hammad Y.A.

    منشور في 2018
    "…The transport time significantly decreased from an initial majority of > 15 mins duration, to a majority of < 15 mins transport time after the second audit; there was a 50% improvement in 30 mins response time; and the percentage of requests processed in < 10 mins were significantly higher after the second audit. …"
    احصل على النص الكامل
  2. 2
  3. 3
  4. 4
  5. 5

    Usefulness of In-Situ Synchrotron Study on Scale Formation during CO2 Corrosion of Mild Steel: A Review حسب Sk, Mobbassar Hassan

    منشور في 2016
    "…This work shades light on how in-situ synchrotron study revealed apparent mysteries related to formation & growth of siderite scale during CO2- corrosion of mild steel. Keywords: In-situ synchrotron, CO2-Corrosion of mild steel, Nucleation mechanism during CO2- corrosion. …"
    احصل على النص الكامل
    احصل على النص الكامل
  6. 6

    The Formation of Sulfide Scales on Carbon Steel in Saturated H2S حسب Al-Qahtani, Noora

    منشور في 2020
    "…There are three contributing elements of corrosion of Carbon Steel in H2S environment: the effect of H2S on water chemistry; electrochemical reactions of the bare iron surface (both anodic and cathodic processes); and the formation and growth of corrosion product layers. …"
    احصل على النص الكامل
    احصل على النص الكامل
  7. 7

    The Formation of Sulfide Scales on Carbon Steel in Saturated H2S حسب Alqahtani, Noora

    منشور في 2020
    "…"There are three contributing elements of corrosion of Carbon Steel in H?S environment: the effect of H2S on water chemistry; electrochemical reactions of the bare iron surface (both anodic and cathodic processes); and the formation and growth of corrosion product layers. …"
    احصل على النص الكامل
    احصل على النص الكامل
  8. 8

    Corrosion behavior of API X100 steel material in a hydrogen sulfide environment حسب Okonkwo, Paul C.

    منشور في 2017
    "…The results indicate that the corrosion rate of API X100 steel decreases with increasing H2S bubbling time due to the increase in H2S concentration in 3.5% NaCl solutions. …"
    احصل على النص الكامل
    احصل على النص الكامل
  9. 9

    Impact of fines type on gas flow using 3D micro-computed tomography حسب Al-Raoush, Riyadh

    منشور في 2019
    "…Images were processed for 3D visualization, segmentation and quantification for each system. …"
    احصل على النص الكامل
    احصل على النص الكامل
  10. 10

    Impact of fines type on gas flow using 3D micro-computed tomography حسب Al-Raoush, Riyadh

    منشور في 2019
    "…Images were processed for 3D visualization, segmentation and quantification for each system. …"
    احصل على النص الكامل
  11. 11

    Performance and computational studies of two soluble pyran derivatives as corrosion inhibitors for mild steel in HCl حسب Khattabi M.

    منشور في 2019
    "…The present study is aiming to explore the effect of 4-Hydroxy-6-methyl-3-(3-quinolin-8-yl-acryloyl)-pyran-2-one (HMQP) and 3-[3-(4-Dimethylamino-phenyl)-acryloyl]-4-hydroxy-6-methyl-pyran-2-one (DMPHP) on mild steel (MS) corrosion in acid solution (1 M HCl). …"
    احصل على النص الكامل
    احصل على النص الكامل
  12. 12

    Effect of octylphenol polyethylene oxide on the corrosion inhibition of steel in 0.5 M H2SO4 حسب Algaber, A.S

    منشور في 2004
    "…A non-ionic surfactant, octylphenol polyethylene oxide (OPPEO), was evaluated as an inhibitor for corrosion of low-carbon steel in 0.5M H 2SO4. Potentiodynamic and potentiostatic methods and scanning electron microscopy were used to study the inhibition effectiveness of the surfactant. …"
    احصل على النص الكامل
    احصل على النص الكامل
  13. 13

    Local supersaturation and the growth of protective scales during CO2 corrosion of steel: Effect of pH and solution flow حسب Sk, Mobbassar Hassan

    منشور في 2017
    "…By correlating in-situ synchrotron X-ray diffraction measurements with electrochemical measurements using a rotating disc electrode, we demonstrate the critical dependence on the local supersaturation of the kinetics of formation of a protective crystalline scale on the surface of carbon steel during CO2 corrosion in brine at elevated temperature. …"
    احصل على النص الكامل
    احصل على النص الكامل
  14. 14

    Understanding the Scales Formation Inhibition Mechanism on C-Steel in a Sour Media حسب Al-Qahtani, Noora

    منشور في 2019
    "…To control such formation scales of iron sulfides, it is essential to understand the mechanisms of corrosion inhibition in H2S systems. In this work, the electrochemical behaviour of C-steel in sour (i) de-ionised water (DIW) and (ii) in different NaCl solutions were examined in an H2S system. …"
    احصل على النص الكامل
    احصل على النص الكامل
  15. 15

    Biodegradable polysaccharide grafted polyacrylamide inhibitor for corrosion in CO2- saturated saline solution حسب Jalab, Rem

    منشور في 2023
    "…Lastly, potentiostatic testing of steel with AGGPAM at an applied potential of 50 mV illustrated surface protection and decreased current over a prolonged time. …"
    احصل على النص الكامل
    احصل على النص الكامل
  16. 16
  17. 17

    An investigation of endometrial vascularity in normally menstruating women and those in other physiological states using 3D ultrasound imaging حسب Khan, Ammar Ahmed

    منشور في 2024
    "…Conclusions: Endometrial vascular indices measured using 3D Doppler can be used to determine normal vascular indices and vary with physiological states such as after miscarriages, postnatally and in the menopausal states.…"
    احصل على النص الكامل
    احصل على النص الكامل
    احصل على النص الكامل
  18. 18
  19. 19

    Impact Of Fines On Gas Relative Permeability Through Sand Using Pore Networks From 3d Synchrotron Micro-Computed Tomography حسب Hannun, Jamal Adel Ibrahim

    منشور في 2019
    "…Micro-computed tomography images were processed for 3D visualization, quantification and pore network modeling. …"
    احصل على النص الكامل
  20. 20

    Biocorrosion behavior of biodegradable nanocomposite fibers coated layer-by-layer on AM50 magnesium implant حسب Abdal-hay, Abdalla

    منشور في 2016
    "…The results showed that the AJS 3D membrane fiber layers, particularly the hybrid membrane layers containing a small amount of nHA (3wt.%), induce a higher biocorrosion resistance and effectively decrease the initial degradation rate compared with the neat AM50 coupon samples. …"
    احصل على النص الكامل
    احصل على النص الكامل