Showing 1 - 20 results of 533 for search '(( 50 ((na decrease) OR (_ decrease)) ) OR ((( 10 mg decrease ) OR ( _ stem decrease ))))*', query time: 0.19s Refine Results
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6

    Biocorrosion behavior of biodegradable nanocomposite fibers coated layer-by-layer on AM50 magnesium implant by Abdal-hay, Abdalla

    Published 2016
    “…The results showed that the AJS 3D membrane fiber layers, particularly the hybrid membrane layers containing a small amount of nHA (3wt.%), induce a higher biocorrosion resistance and effectively decrease the initial degradation rate compared with the neat AM50 coupon samples. …”
    Get full text
    Get full text
  7. 7

    Functionally graded porous femoral stem: Computational Analysis by Tarlochan F.

    Published 2019
    “…The gradation scheme was decreasing the porosity distally. From this study, it was found that functionally graded porous stems in comparison to fully dense stems, transfers up to 170% of the stresses to the bone (reduce stress shielding) and have micromotion that supports bone in growth.…”
    Get full text
    Get full text
  8. 8

    Effect of copper-nickel interlayer thickness on laser welding-brazing of Mg/Ti alloy by Auwal, S.T.

    Published 2019
    “…Dissimilar lap joining of AZ31B Mg alloy to Cu-Ni coated Ti-6Al-4V was carried out by laser welding-brazing method. …”
    Get full text
    Get full text
  9. 9
  10. 10

    The mitochondrial-related effect of the 905 nm photobiomodulation therapy on 50B11 sensory neurons by Zupin, Luisa

    Published 2023
    “…In this study, a possible molecular mechanism of the 905 nm PBMT (0.25 W/cm2; 3, 6, 12, and 18 J/cm2, 5 Hz) analgesic effect was tested on 50B11 cells, by investigating its impact on mitochondria. …”
    Get full text
    Get full text
    Get full text
  11. 11
  12. 12
  13. 13

    Impact of trace noble metals on the catalytic performance of LaNiMgO towards methane dry reforming by Mohamed, Assem T.

    Published 2024
    “…On the other hand, at the same time-on-stream LaNiMgO-Rh lost 0.3 and 0.7 % of its maximum CO2 and CH4 conversions, respectively.In durability measurements, and after 140h LaNiMgO-Rh exhibited slight decay in the CO2 conversion from 77.6 % to 70.5%, the CH4 conversion decreased from 72.3% to 64.2%. On the other hand, LaNiMgO-Pd depicted rapid decay in the CO2 conversion from 68.3 % to 49.3 % and the CH4 conversion felled from 66.5 % to 41.5 % after 50h. …”
    Get full text
    Get full text
    Get full text
    article
  14. 14
  15. 15
  16. 16

    Quality improvement can decrease blood delivery turnaround time: Evidence from a single tertiary-care academic medical center by Hammad Y.A.

    Published 2018
    “…The transport time significantly decreased from an initial majority of > 15 mins duration, to a majority of < 15 mins transport time after the second audit; there was a 50% improvement in 30 mins response time; and the percentage of requests processed in < 10 mins were significantly higher after the second audit. …”
    Get full text
  17. 17
  18. 18
  19. 19

    Finite element study of functionally graded porous femoral stems incorporating body-centered cubic structure by Alkhatib, Sami E.

    Published 2019
    “…Three levels of porosities (20%, 50%, and 80%) were modeled in HGP and FGP stems. …”
    Get full text
    Get full text
  20. 20