Showing 1 - 9 results of 9 for search '(( 50 ppm decrease ) OR ((( 50 a decrease ) OR ( 5 ((mm decrease) OR (_ decrease)) ))))~', query time: 1.23s Refine Results
  1. 1

    A 60-year-old male with a hyperacute cardioembolic infarction fifteen hours after the onset. by Daichi Momosaka (6160418)

    Published 2020
    “…<b>G:</b> MTR<sub>asym</sub> spectra show decreased MTR<sub>asym</sub> (3.5ppm) or APTW signal (%) in the infarct area compared to the CNAWM. mRS, modified Rankin Scale; NIHSS, National Institutes of Health Stroke Scale; FLAIR, fluid attenuated inversion recovery; DWI, diffusion-weighted imaging; ROI, region-of-interest; ADC, apparent diffusion coefficient; APTW, amide proton transfer-weighted; CEST, chemical exchange saturation transfer; CNAWM, contralateral normal-appearing white matter; S<sub>sat</sub>(ppm) and S0, the signal intensities obtained with and without selective radiofrequency saturation pulse irradiation, respectively; APT<sub>10</sub>, APT<sub>25</sub>, APT<sub>50</sub>, APT<sub>75</sub>, and APT<sub>90</sub> correspond to the 10th, 25th, 50th, 75th, and 90th percentiles of the APTW signal value within the ROI, respectively.…”
  2. 2

    A 59-year-old male with a subacute atherosclerotic infarction nine days after the onset. by Daichi Momosaka (6160418)

    Published 2020
    “…<b>G:</b> MTR<sub>asym</sub> spectra show decreased MTR<sub>asym</sub>(3.5ppm) or APTW signal (%) in the infarct area compared to the CNAWM. mRS, modified Rankin Scale; NIHSS, National Institutes of Health Stroke Scale; FLAIR, fluid attenuated inversion recovery; DWI, diffusion-weighted imaging; ROI, region-of-interest; ADC, apparent diffusion coefficient; APTW, amide proton transfer-weighted; CEST, chemical exchange saturation transfer; CNAWM, contralateral normal-appearing white matter; S<sub>sat</sub> (ppm) and S<sub>0</sub>, the signal intensities obtained with and without selective radiofrequency saturation pulse irradiation, respectively; APT<sub>10</sub>, APT<sub>25</sub>, APT<sub>50</sub>, APT<sub>75</sub>, and APT<sub>90</sub>, correspond to the 10th, 25th, 50th, 75th, and 90th percentiles of APTW signal value, respectively.…”
  3. 3

    A 27-year-old female with an acute cardioembolic infarction fifteen hours after the onset. by Daichi Momosaka (6160418)

    Published 2020
    “…<b>G:</b> MTR<sub>asym</sub> spectra show decreased MTR<sub>asym</sub>(3.5ppm) or APTW signal (%) in the infarct area compared to the CNAWM. mRS, modified Rankin Scale; NIHSS, National Institutes of Health Stroke Scale; FLAIR, fluid attenuated inversion recovery; DWI, diffusion-weighted imaging; ROI, region-of-interest; ADC, apparent diffusion coefficient; APTW, amide proton transfer-weighted; CEST, chemical exchange saturation transfer; CNAWM, contralateral normal-appearing white matter; S<sub>sat</sub>(ppm) and S<sub>0</sub>, the signal intensities obtained with and without selective radiofrequency saturation pulse irradiation, respectively; APT<sub>10</sub>, APT<sub>25</sub>, APT<sub>50</sub>, APT<sub>75</sub>, and APT<sub>90</sub>, correspond to the 10th, 25th, 50th, 75th, and 90th percentiles of APTW signal value, respectively.…”
  4. 4

    Complementary interactions of cysteine and Fe(II) with 6PG. by Gabriel Piedrafita (155328)

    Published 2021
    “…<b>(B)</b> Representative <sup>1</sup>H-NMR spectra of 6PG alone, cysteine alone, or the combination of both (20 mM of each analyte) in 50 mM phosphate pH 5/D<sub>2</sub>O solutions, either in the absence or presence of 1 mM FeCl<sub>2</sub>. …”
  5. 5
  6. 6

    I-R-Polar-Negative-0902 by Sheng-Yuan Ho (16909464)

    Published 2023
    “…A UPLC BEH C18 guard column (1.7 μm, 5 mm) was employed as the reverse-phase column. …”
  7. 7

    Untargeted <i>In Vitro</i> Metabolomics data from <i>Burkholderia cenocepacia </i>J2315, H111 and <i>Staphylococcus aureus </i>NRS77 Biofilm Supernatant by Hayden Skaggs (20833868)

    Published 2025
    “…Thresholds were set as spectral similarity ≥ 0.4, retention time difference ≤ 0.15 and m/z variation window ≤ 5 ppm. 2D LC-MS/MS data without a match with the metabolites in the proprietary database were further analyzed using Compound Discoverer software (v 2.0, Thermo Fisher Scientific, Germany), where MS/MS spectra similarity score threshold was set ≥ 40 with a maximum score of 100. …”
  8. 8

    <strong>Drought re-routes soil microbial carbon metabolism towards emission of volatile metabolites in an artificial tropical rainforest</strong> by Linnea Honeker (13113813)

    Published 2023
    “…NMR spectra were acquired on a Bruker Avance III spectrometer operating at a field strength of 17.6 T (1H ν0 of 750.24 MHz) and equipped with a 5 mm Bruker TCI/CP HCN (inverse) cryoprobe with Z-gradient and at a regulated temperature of 298 K. …”
  9. 9

    Impacts of winter climate change on northern forest understory carbon dioxide exchange determined by reindeer grazing by Noora Kantola (14263490)

    Published 2025
    “…CO2 concentration (ppm), relative humidity (%), and temperature (℃) during each manual measurement were logged every 5 sec for 2 min with a handheld logger (model MI70, Vaisala Inc.). …”